feat: migration von directus zu payloadcms
Some checks failed
Build & Deploy / 🔍 Prepare (push) Successful in 1m19s
Build & Deploy / 🧪 QA (push) Failing after 3m32s
Build & Deploy / 🚀 Deploy (push) Has been skipped
Build & Deploy / 🏗️ Build (push) Failing after 7m51s
Build & Deploy / ⚡ Lighthouse (push) Has been skipped
Build & Deploy / 🧪 Smoke Test (push) Has been skipped
Build & Deploy / ♿ WCAG (push) Has been skipped
Build & Deploy / 🛡️ Quality Gates (push) Has been skipped
Build & Deploy / 🔔 Notify (push) Successful in 10s
Some checks failed
Build & Deploy / 🔍 Prepare (push) Successful in 1m19s
Build & Deploy / 🧪 QA (push) Failing after 3m32s
Build & Deploy / 🚀 Deploy (push) Has been skipped
Build & Deploy / 🏗️ Build (push) Failing after 7m51s
Build & Deploy / ⚡ Lighthouse (push) Has been skipped
Build & Deploy / 🧪 Smoke Test (push) Has been skipped
Build & Deploy / ♿ WCAG (push) Has been skipped
Build & Deploy / 🛡️ Quality Gates (push) Has been skipped
Build & Deploy / 🔔 Notify (push) Successful in 10s
This commit is contained in:
@@ -220,29 +220,29 @@ locale: en
|
||||
]
|
||||
}} />}>
|
||||
|
||||
<section>
|
||||
<h3 data-start="460" data-end="518">For long-term use in demanding environments</h3>
|
||||
<p data-start="520" data-end="953">The <strong data-start="524" data-end="536">H1Z2Z2-K</strong> complies with <strong data-start="552" data-end="588">DIN EN 50618 (VDE 0283-618)</strong> and is specifically designed for the <strong data-start="614" data-end="654">cabling of photovoltaic systems</strong>. It can be <strong data-start="675" data-end="713">installed permanently or used flexibly</strong> – indoors, outdoors, in industrial facilities, agricultural operations, or even in <strong data-start="812" data-end="847">hazardous (explosive) areas</strong>. The cable is <strong data-start="865" data-end="905">UV-, ozone- and water-resistant (AD7)</strong> and can be <strong data-start="915" data-end="945">laid directly in the ground</strong>.</p>
|
||||
<h3 data-start="955" data-end="990">Construction and technical features</h3>
|
||||
<p data-start="992" data-end="1516">The finely stranded <strong data-start="1009" data-end="1045">tinned copper conductor (class 5)</strong> is double protected by <strong data-start="1079" data-end="1160">cross-linked insulation and a cross-linked outer sheath made of polyolefin copolymer</strong> – halogen-free, flame-retardant, and highly abrasion-resistant. The cable is designed for a maximum conductor temperature of <strong data-start="1273" data-end="1283">120 °C</strong> and remains reliably flexible even at <strong data-start="1314" data-end="1339">-40 °C (fixed installation)</strong>. Its <strong data-start="1366" data-end="1394">low smoke emission</strong> and high resistance to mechanical and thermal stress ensure safe, long-term operation.</p>
|
||||
<h3 data-start="1518" data-end="1549">Key features at a glance</h3>
|
||||
<ul data-start="1551" data-end="1815">
|
||||
<li data-start="1551" data-end="1604">
|
||||
<p data-start="1553" data-end="1604"><strong data-start="1553" data-end="1604">Halogen-free, flame-retardant, UV- and ozone-resistant</strong></p>
|
||||
|
||||
<h3>For long-term use in demanding environments</h3>
|
||||
<p>The <strong>H1Z2Z2-K</strong> complies with <strong>DIN EN 50618 (VDE 0283-618)</strong> and is specifically designed for the <strong>cabling of photovoltaic systems</strong>. It can be <strong>installed permanently or used flexibly</strong> – indoors, outdoors, in industrial facilities, agricultural operations, or even in <strong>hazardous (explosive) areas</strong>. The cable is <strong>UV-, ozone- and water-resistant (AD7)</strong> and can be <strong>laid directly in the ground</strong>.</p>
|
||||
<h3>Construction and technical features</h3>
|
||||
<p>The finely stranded <strong>tinned copper conductor (class 5)</strong> is double protected by <strong>cross-linked insulation and a cross-linked outer sheath made of polyolefin copolymer</strong> – halogen-free, flame-retardant, and highly abrasion-resistant. The cable is designed for a maximum conductor temperature of <strong>120 °C</strong> and remains reliably flexible even at <strong>-40 °C (fixed installation)</strong>. Its <strong>low smoke emission</strong> and high resistance to mechanical and thermal stress ensure safe, long-term operation.</p>
|
||||
<h3>Key features at a glance</h3>
|
||||
<ul>
|
||||
<li>
|
||||
<p><strong>Halogen-free, flame-retardant, UV- and ozone-resistant</strong></p>
|
||||
</li>
|
||||
<li data-start="1605" data-end="1666">
|
||||
<p data-start="1607" data-end="1666"><strong data-start="1607" data-end="1666">Short-circuit and earth fault proof according to VDE-AR-E 2283-4</strong></p>
|
||||
<li>
|
||||
<p><strong>Short-circuit and earth fault proof according to VDE-AR-E 2283-4</strong></p>
|
||||
</li>
|
||||
<li data-start="1667" data-end="1744">
|
||||
<p data-start="1669" data-end="1744"><strong data-start="1669" data-end="1744">Approved for indoor, outdoor and hazardous (explosive) areas</strong></p>
|
||||
<li>
|
||||
<p><strong>Approved for indoor, outdoor and hazardous (explosive) areas</strong></p>
|
||||
</li>
|
||||
<li data-start="1745" data-end="1784">
|
||||
<p data-start="1747" data-end="1784"><strong data-start="1747" data-end="1784">Suitable for direct burial</strong></p>
|
||||
<li>
|
||||
<p><strong>Suitable for direct burial</strong></p>
|
||||
</li>
|
||||
<li data-start="1785" data-end="1815">
|
||||
<p data-start="1787" data-end="1815"><strong data-start="1787" data-end="1815">CPR performance class: Eca</strong></p>
|
||||
<li>
|
||||
<p><strong>CPR performance class: Eca</strong></p>
|
||||
</li>
|
||||
</ul>
|
||||
</section>
|
||||
|
||||
|
||||
</ProductTabs>
|
||||
|
||||