Files
klz-cables.com/data/products/en/solar-cables/h1z2z2-k.mdx
Marc Mintel f7aa880d9f
Some checks failed
Build & Deploy / 🔍 Prepare (push) Successful in 1m19s
Build & Deploy / 🧪 QA (push) Failing after 3m32s
Build & Deploy / 🚀 Deploy (push) Has been skipped
Build & Deploy / 🏗️ Build (push) Failing after 7m51s
Build & Deploy / ⚡ Lighthouse (push) Has been skipped
Build & Deploy / 🧪 Smoke Test (push) Has been skipped
Build & Deploy / ♿ WCAG (push) Has been skipped
Build & Deploy / 🛡️ Quality Gates (push) Has been skipped
Build & Deploy / 🔔 Notify (push) Successful in 10s
feat: migration von directus zu payloadcms
2026-02-24 19:25:43 +01:00

249 lines
6.3 KiB
Plaintext
Raw Blame History

This file contains invisible Unicode characters
This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
---
title: H1Z2Z2-K
sku: H1Z2Z2-K-solar-cables
description: >
The H1Z2Z2-K cable is a highly flexible, halogen-free solar cable for modern
photovoltaic systems. It meets the highest standards for safety, weather
resistance, and electrical performance for both indoor and outdoor use.
categories:
- Solar Cables
images:
- /uploads/2025/06/H1Z2Z2-K-scaled.webp
application: >
The H1Z2Z2-K complies with DIN EN 50618 (VDE 0283-618) and is specifically designed for
the cabling of photovoltaic systems. It can be installed permanently or used flexibly
indoors, outdoors, in industrial facilities, agricultural operations, or even in
hazardous (explosive) areas. The cable is UV-, ozone- and water-resistant (AD7) and
can be laid directly in the ground.
locale: en
---
<ProductTabs technicalData={<ProductTechnicalData data={{
"technicalItems": [
{
"label": "Maximal operating conductor temperature (°C)",
"value": "120",
"unit": "°C"
},
{
"label": "Maximal short-circuit temperature (°C)",
"value": "+250 Max. 5 sec.",
"unit": "°C"
},
{
"label": "Minimal temperature for laying (°C)",
"value": "-25",
"unit": "°C"
},
{
"label": "Operating temperature range (°C)",
"value": "-40/+90",
"unit": "°C"
},
{
"label": "Rated voltage (kV)",
"value": "AC: 1000/1000 V DC: 1500 V",
"unit": "kV"
},
{
"label": "Shape of conductor",
"value": "RM",
"unit": ""
},
{
"label": "Test voltage (kV)",
"value": "6,5 AC, 15 DC (5 min.)",
"unit": "kV"
}
],
"voltageTables": [
{
"voltageLabel": "AC: 1000 / 1000 V DC: 1500 V",
"metaItems": [
{
"label": "Voltage",
"value": "AC: 1000 / 1000 V DC: 1500 V"
},
{
"label": "Test voltage",
"value": "6,5 AC, 15 DC (5 min.)",
"unit": "kV"
},
{
"label": "Operating temperature range",
"value": "-40/+90",
"unit": "°C"
},
{
"label": "Conductor temperature (max.)",
"value": "120",
"unit": "°C"
},
{
"label": "Short-circuit temperature (max.)",
"value": "+250 Max. 5 sec.",
"unit": "°C"
},
{
"label": "Minimum laying temperature",
"value": "-25",
"unit": "°C"
}
],
"columns": [
{
"key": "Cond",
"label": "Cond."
},
{
"key": "shape",
"label": "Shape"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x1,5",
"cells": [
"",
"RM",
"13.7",
"22",
"4.5",
"33"
]
},
{
"configuration": "1x2,5",
"cells": [
"",
"RM",
"8.21",
"24",
"4.9",
"41"
]
},
{
"configuration": "1x4",
"cells": [
"",
"RM",
"5.09",
"26",
"5.5",
"57"
]
},
{
"configuration": "1x6",
"cells": [
"",
"RM",
"3.39",
"30",
"5.9",
"73"
]
},
{
"configuration": "1x10",
"cells": [
"",
"RM",
"1.95",
"35",
"6.9",
"110"
]
},
{
"configuration": "1x16",
"cells": [
"",
"RM",
"1.24",
"40",
"8",
"170"
]
},
{
"configuration": "1x25",
"cells": [
"",
"RM",
"0.795",
"50",
"10",
"260"
]
},
{
"configuration": "1x35",
"cells": [
"",
"RM",
"0.565",
"56",
"11",
"360"
]
},
{
"configuration": "1x50",
"cells": [
"",
"RM",
"0.393",
"60",
"13.2",
"500"
]
}
]
}
]
}} />}>
<h3>For long-term use in demanding environments</h3>
<p>The <strong>H1Z2Z2-K</strong> complies with <strong>DIN EN 50618 (VDE 0283-618)</strong> and is specifically designed for the <strong>cabling of photovoltaic systems</strong>. It can be <strong>installed permanently or used flexibly</strong> indoors, outdoors, in industrial facilities, agricultural operations, or even in <strong>hazardous (explosive) areas</strong>. The cable is <strong>UV-, ozone- and water-resistant (AD7)</strong> and can be <strong>laid directly in the ground</strong>.</p>
<h3>Construction and technical features</h3>
<p>The finely stranded <strong>tinned copper conductor (class 5)</strong> is double protected by <strong>cross-linked insulation and a cross-linked outer sheath made of polyolefin copolymer</strong> halogen-free, flame-retardant, and highly abrasion-resistant. The cable is designed for a maximum conductor temperature of <strong>120°C</strong> and remains reliably flexible even at <strong>-40°C (fixed installation)</strong>. Its <strong>low smoke emission</strong> and high resistance to mechanical and thermal stress ensure safe, long-term operation.</p>
<h3>Key features at a glance</h3>
<ul>
<li>
<p><strong>Halogen-free, flame-retardant, UV- and ozone-resistant</strong></p>
</li>
<li>
<p><strong>Short-circuit and earth fault proof according to VDE-AR-E 2283-4</strong></p>
</li>
<li>
<p><strong>Approved for indoor, outdoor and hazardous (explosive) areas</strong></p>
</li>
<li>
<p><strong>Suitable for direct burial</strong></p>
</li>
<li>
<p><strong>CPR performance class: Eca</strong></p>
</li>
</ul>
</ProductTabs>