feat: migration von directus zu payloadcms
Some checks failed
Build & Deploy / 🔍 Prepare (push) Successful in 1m19s
Build & Deploy / 🧪 QA (push) Failing after 3m32s
Build & Deploy / 🚀 Deploy (push) Has been skipped
Build & Deploy / 🏗️ Build (push) Failing after 7m51s
Build & Deploy / ⚡ Lighthouse (push) Has been skipped
Build & Deploy / 🧪 Smoke Test (push) Has been skipped
Build & Deploy / ♿ WCAG (push) Has been skipped
Build & Deploy / 🛡️ Quality Gates (push) Has been skipped
Build & Deploy / 🔔 Notify (push) Successful in 10s
Some checks failed
Build & Deploy / 🔍 Prepare (push) Successful in 1m19s
Build & Deploy / 🧪 QA (push) Failing after 3m32s
Build & Deploy / 🚀 Deploy (push) Has been skipped
Build & Deploy / 🏗️ Build (push) Failing after 7m51s
Build & Deploy / ⚡ Lighthouse (push) Has been skipped
Build & Deploy / 🧪 Smoke Test (push) Has been skipped
Build & Deploy / ♿ WCAG (push) Has been skipped
Build & Deploy / 🛡️ Quality Gates (push) Has been skipped
Build & Deploy / 🔔 Notify (push) Successful in 10s
This commit is contained in:
@@ -388,13 +388,13 @@ locale: de
|
||||
]
|
||||
}} />}>
|
||||
|
||||
<section>
|
||||
<h3 data-start="452" data-end="502">Entwickelt für leistungsstarke Netzumgebungen</h3>
|
||||
<p data-start="504" data-end="904">Das <strong data-start="508" data-end="521">N2XS(F)2Y</strong> erfüllt die gängigen Normen <strong data-start="550" data-end="570">DIN VDE 0276-620</strong>, <strong data-start="572" data-end="585">HD 620 S2</strong> und <strong data-start="590" data-end="603">IEC 60502</strong> und ist für die <strong data-start="620" data-end="713">Verlegung in Innenräumen, Kabelkanälen, im Freien, in Wasser, Erde und auf Kabelpritschen</strong> geeignet. Besonders in <strong data-start="737" data-end="785">EVU-Netzen, Industrieanlagen und Kraftwerken</strong> spielt dieses Kabel seine Stärken aus – überall dort, wo Langlebigkeit, Wasserdichtigkeit und Sicherheit gefragt sind.</p>
|
||||
<h3 data-start="906" data-end="946">Aufbau und technische Eigenschaften</h3>
|
||||
<p data-start="948" data-end="1387">Im Inneren befindet sich ein <strong data-start="977" data-end="1016">blanker, mehrdrähtiger Kupferleiter</strong> (Klasse 2), umgeben von einer <strong data-start="1047" data-end="1123">extrudierten VPE-Isolation mit innerer und haftender äußerer Leitschicht</strong>. Eine <strong data-start="1130" data-end="1174">längswasserdichte, leitfähige Bandierung</strong>, eine <strong data-start="1181" data-end="1234">Abschirmung aus Kupferdrähten mit Querleitwendeln</strong> und eine zusätzliche <strong data-start="1256" data-end="1282">längswasserdichte Lage</strong> sichern den Aufbau. Der schwarze <strong data-start="1316" data-end="1345">PE-Außenmantel (Typ DMP2)</strong> sorgt für hohe mechanische Belastbarkeit.</p>
|
||||
<h3 data-start="1389" data-end="1425">Anwendungsbereiche und Vorteile</h3>
|
||||
<p data-start="1427" data-end="1822">Das N2XS(F)2Y ist <strong data-start="1445" data-end="1461">erdverlegbar</strong>, <strong data-start="1463" data-end="1509">resistent gegen aggressive Umwelteinflüsse</strong> und hält <strong data-start="1519" data-end="1562">Temperaturen bis +90 °C im Dauerbetrieb</strong> sowie <strong data-start="1569" data-end="1599">+250 °C im Kurzschlussfall</strong> stand. Es ist <strong data-start="1614" data-end="1663">frei von silikon- und cadmiumhaltigen Stoffen</strong> und dank des <strong data-start="1677" data-end="1709">teilentladungsfreien Aufbaus</strong> besonders geeignet für Netze mit höchsten Anforderungen an <strong data-start="1769" data-end="1803">elektrische Betriebssicherheit</strong> und Langlebigkeit.</p>
|
||||
</section>
|
||||
|
||||
<h3>Entwickelt für leistungsstarke Netzumgebungen</h3>
|
||||
<p>Das <strong>N2XS(F)2Y</strong> erfüllt die gängigen Normen <strong>DIN VDE 0276-620</strong>, <strong>HD 620 S2</strong> und <strong>IEC 60502</strong> und ist für die <strong>Verlegung in Innenräumen, Kabelkanälen, im Freien, in Wasser, Erde und auf Kabelpritschen</strong> geeignet. Besonders in <strong>EVU-Netzen, Industrieanlagen und Kraftwerken</strong> spielt dieses Kabel seine Stärken aus – überall dort, wo Langlebigkeit, Wasserdichtigkeit und Sicherheit gefragt sind.</p>
|
||||
<h3>Aufbau und technische Eigenschaften</h3>
|
||||
<p>Im Inneren befindet sich ein <strong>blanker, mehrdrähtiger Kupferleiter</strong> (Klasse 2), umgeben von einer <strong>extrudierten VPE-Isolation mit innerer und haftender äußerer Leitschicht</strong>. Eine <strong>längswasserdichte, leitfähige Bandierung</strong>, eine <strong>Abschirmung aus Kupferdrähten mit Querleitwendeln</strong> und eine zusätzliche <strong>längswasserdichte Lage</strong> sichern den Aufbau. Der schwarze <strong>PE-Außenmantel (Typ DMP2)</strong> sorgt für hohe mechanische Belastbarkeit.</p>
|
||||
<h3>Anwendungsbereiche und Vorteile</h3>
|
||||
<p>Das N2XS(F)2Y ist <strong>erdverlegbar</strong>, <strong>resistent gegen aggressive Umwelteinflüsse</strong> und hält <strong>Temperaturen bis +90 °C im Dauerbetrieb</strong> sowie <strong>+250 °C im Kurzschlussfall</strong> stand. Es ist <strong>frei von silikon- und cadmiumhaltigen Stoffen</strong> und dank des <strong>teilentladungsfreien Aufbaus</strong> besonders geeignet für Netze mit höchsten Anforderungen an <strong>elektrische Betriebssicherheit</strong> und Langlebigkeit.</p>
|
||||
|
||||
|
||||