fix(pdf): fix Lexical AST text extraction to prevent [object Object] in datasheets
Some checks failed
Build & Deploy / 🔍 Prepare (push) Successful in 10s
Build & Deploy / 🧪 QA (push) Successful in 1m11s
Build & Deploy / 🏗️ Build (push) Successful in 2m17s
Build & Deploy / 🚀 Deploy (push) Successful in 15s
Build & Deploy / 🧪 Post-Deploy Verification (push) Successful in 1m14s
Build & Deploy / 🔔 Notify (push) Successful in 3s
Nightly QA / 💨 Smoke & Health (push) Failing after 44s
Some checks failed
Build & Deploy / 🔍 Prepare (push) Successful in 10s
Build & Deploy / 🧪 QA (push) Successful in 1m11s
Build & Deploy / 🏗️ Build (push) Successful in 2m17s
Build & Deploy / 🚀 Deploy (push) Successful in 15s
Build & Deploy / 🧪 Post-Deploy Verification (push) Successful in 1m14s
Build & Deploy / 🔔 Notify (push) Successful in 3s
Nightly QA / 💨 Smoke & Health (push) Failing after 44s
This commit is contained in:
266
data/products/en/na2xfk2y.mdx
Normal file
266
data/products/en/na2xfk2y.mdx
Normal file
@@ -0,0 +1,266 @@
|
||||
---
|
||||
title: NA2X(F)K2Y
|
||||
sku: NA2X(F)K2Y-high-voltage-cables
|
||||
description: >
|
||||
The NA2X(F)K2Y high-voltage cable series is designed for industrial
|
||||
applications requiring robust electrical performance, featuring copper
|
||||
conductors and XLPE insulation suitable for voltage classes up to 110kV.
|
||||
Primarily used in power transmission and distribution networks.
|
||||
categories:
|
||||
- High Voltage Cables
|
||||
images: []
|
||||
application: >
|
||||
The NA2X(F)K2Y high-voltage cable series is engineered to meet the rigorous demands
|
||||
of modern industrial and power distribution applications. It combines high-grade
|
||||
copper conductors with cross-linked polyethylene (XLPE) insulation, ensuring
|
||||
superior dielectric strength and thermal cycling resilience.
|
||||
locale: en
|
||||
---
|
||||
<ProductTabs technicalData={<ProductTechnicalData data={{
|
||||
"technicalItems": [
|
||||
{
|
||||
"label": "Rated voltage (kV)",
|
||||
"value": "64/110",
|
||||
"unit": "kV"
|
||||
}
|
||||
],
|
||||
"voltageTables": [
|
||||
{
|
||||
"voltageLabel": "64/110 kV",
|
||||
"metaItems": [
|
||||
{
|
||||
"label": "Voltage",
|
||||
"value": "64/110 kV"
|
||||
}
|
||||
],
|
||||
"columns": [
|
||||
{
|
||||
"key": "Cond",
|
||||
"label": "Cond."
|
||||
},
|
||||
{
|
||||
"key": "RI",
|
||||
"label": "RI [Ohm/km]"
|
||||
},
|
||||
{
|
||||
"key": "Wi",
|
||||
"label": "Wi [mm]"
|
||||
},
|
||||
{
|
||||
"key": "Rbv",
|
||||
"label": "Rbv [mm]"
|
||||
},
|
||||
{
|
||||
"key": "Ø",
|
||||
"label": "Ø [mm]"
|
||||
},
|
||||
{
|
||||
"key": "G",
|
||||
"label": "G [kg/km]"
|
||||
}
|
||||
],
|
||||
"rows": [
|
||||
{
|
||||
"configuration": "1×150RM",
|
||||
"cells": [
|
||||
"Al",
|
||||
"0.26",
|
||||
"18",
|
||||
"1.3",
|
||||
"67",
|
||||
"7360"
|
||||
]
|
||||
},
|
||||
{
|
||||
"configuration": "1×185RM",
|
||||
"cells": [
|
||||
"Al",
|
||||
"0.21",
|
||||
"17",
|
||||
"1.3",
|
||||
"66",
|
||||
"7270"
|
||||
]
|
||||
},
|
||||
{
|
||||
"configuration": "1×240RM",
|
||||
"cells": [
|
||||
"Al",
|
||||
"0.16",
|
||||
"16.5",
|
||||
"1.3",
|
||||
"67",
|
||||
"7480"
|
||||
]
|
||||
},
|
||||
{
|
||||
"configuration": "1×300RM",
|
||||
"cells": [
|
||||
"Al",
|
||||
"0.13",
|
||||
"15.5",
|
||||
"1.3",
|
||||
"67",
|
||||
"7600"
|
||||
]
|
||||
},
|
||||
{
|
||||
"configuration": "1×400RM",
|
||||
"cells": [
|
||||
"Al",
|
||||
"0.1",
|
||||
"14.5",
|
||||
"1.4",
|
||||
"68",
|
||||
"7890"
|
||||
]
|
||||
},
|
||||
{
|
||||
"configuration": "1×500RM",
|
||||
"cells": [
|
||||
"Al",
|
||||
"0.08",
|
||||
"14",
|
||||
"1.4",
|
||||
"70",
|
||||
"8400"
|
||||
]
|
||||
},
|
||||
{
|
||||
"configuration": "1×630RM",
|
||||
"cells": [
|
||||
"Al",
|
||||
"0.06",
|
||||
"14",
|
||||
"1.5",
|
||||
"74",
|
||||
"9390"
|
||||
]
|
||||
},
|
||||
{
|
||||
"configuration": "1×800RM",
|
||||
"cells": [
|
||||
"Al",
|
||||
"0.05",
|
||||
"14",
|
||||
"1.6",
|
||||
"78",
|
||||
"10350"
|
||||
]
|
||||
},
|
||||
{
|
||||
"configuration": "1×1000RM",
|
||||
"cells": [
|
||||
"Al",
|
||||
"0.04",
|
||||
"14",
|
||||
"1.7",
|
||||
"84",
|
||||
"11620"
|
||||
]
|
||||
},
|
||||
{
|
||||
"configuration": "1×1200RMS",
|
||||
"cells": [
|
||||
"Al",
|
||||
"0.03",
|
||||
"14",
|
||||
"1.8",
|
||||
"91",
|
||||
"13250"
|
||||
]
|
||||
},
|
||||
{
|
||||
"configuration": "1×1400RMS",
|
||||
"cells": [
|
||||
"Al",
|
||||
"0.03",
|
||||
"14",
|
||||
"1.9",
|
||||
"93",
|
||||
"14100"
|
||||
]
|
||||
},
|
||||
{
|
||||
"configuration": "1×1600RMS",
|
||||
"cells": [
|
||||
"Al",
|
||||
"0.02",
|
||||
"14",
|
||||
"1.9",
|
||||
"97",
|
||||
"15160"
|
||||
]
|
||||
},
|
||||
{
|
||||
"configuration": "1×1800RMS",
|
||||
"cells": [
|
||||
"Al",
|
||||
"0.02",
|
||||
"14",
|
||||
"2",
|
||||
"101",
|
||||
"16410"
|
||||
]
|
||||
},
|
||||
{
|
||||
"configuration": "1×2000RMS",
|
||||
"cells": [
|
||||
"Al",
|
||||
"0.02",
|
||||
"14",
|
||||
"2.1",
|
||||
"103",
|
||||
"17160"
|
||||
]
|
||||
},
|
||||
{
|
||||
"configuration": "1×2500RMS",
|
||||
"cells": [
|
||||
"Al",
|
||||
"0.02",
|
||||
"14.5",
|
||||
"2.2",
|
||||
"110",
|
||||
"19420"
|
||||
]
|
||||
},
|
||||
{
|
||||
"configuration": "1×3000RMS",
|
||||
"cells": [
|
||||
"Al",
|
||||
"0.01",
|
||||
"14.5",
|
||||
"2.4",
|
||||
"119",
|
||||
"22550"
|
||||
]
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
}} />}>
|
||||
|
||||
<section>
|
||||
<h2>Engineering Overview</h2>
|
||||
<p>The <strong>NA2X(F)K2Y high-voltage cable series</strong> is engineered to meet the rigorous demands of modern industrial and power distribution applications. It combines high-grade copper conductors with cross-linked polyethylene (XLPE) insulation, ensuring superior <strong>dielectric strength</strong> and <strong>thermal cycling</strong> resilience.</p>
|
||||
</section>
|
||||
<section>
|
||||
<h2>Technical Performance and Installation</h2>
|
||||
<p>This cable series is optimized for high <strong>ampacity</strong> and excellent <strong>fault current withstand</strong> capabilities, making it ideal for environments where reliability and durability are paramount. The construction adheres to strict <strong>IEC compliance</strong> standards, ensuring both performance and safety.</p>
|
||||
<ul>
|
||||
<li>Stranded copper conductors enhance current carrying capacity and heat dissipation.</li>
|
||||
<li>XLPE insulation provides significant improvements in thermal characteristics and longevity compared to traditional PVC.</li>
|
||||
<li>Installation versatility with suitability for <strong>direct burial</strong>, <strong>trefoil formation</strong>, or <strong>cable tray mounting</strong>, accommodating various environmental conditions and spatial configurations.</li>
|
||||
</ul>
|
||||
</section>
|
||||
<section>
|
||||
<h2>Compliance and EMC Considerations</h2>
|
||||
<p>The NA2X(F)K2Y series not only meets <strong>IEC</strong> standards but also features a robust design to ensure <strong>electromagnetic compatibility (EMC)</strong>. This design minimizes <strong>induced voltage</strong> effects, crucial in densely populated cable routes and close proximity to sensitive equipment.</p>
|
||||
<ul>
|
||||
<li>Comprehensive <strong>CPR classification</strong> and <strong>CE marking</strong> confirm the cable's adherence to European safety and quality benchmarks.</li>
|
||||
<li>Metallic screens incorporated within the cable structure effectively manage electromagnetic interference, safeguarding signal integrity across extensive networks.</li>
|
||||
</ul>
|
||||
</section>
|
||||
|
||||
</ProductTabs>
|
||||
Reference in New Issue