Files
klz-cables.com/data/products/de/solarkabel/h1z2z2-k.mdx
Marc Mintel f7aa880d9f
Some checks failed
Build & Deploy / 🔍 Prepare (push) Successful in 1m19s
Build & Deploy / 🧪 QA (push) Failing after 3m32s
Build & Deploy / 🚀 Deploy (push) Has been skipped
Build & Deploy / 🏗️ Build (push) Failing after 7m51s
Build & Deploy / ⚡ Lighthouse (push) Has been skipped
Build & Deploy / 🧪 Smoke Test (push) Has been skipped
Build & Deploy / ♿ WCAG (push) Has been skipped
Build & Deploy / 🛡️ Quality Gates (push) Has been skipped
Build & Deploy / 🔔 Notify (push) Successful in 10s
feat: migration von directus zu payloadcms
2026-02-24 19:25:43 +01:00

250 lines
6.4 KiB
Plaintext
Raw Blame History

This file contains invisible Unicode characters
This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
---
title: H1Z2Z2-K
sku: H1Z2Z2-K-solar-cables
description: >
Das H1Z2Z2-K Kabel ist ein hochflexibles, halogenfreies Solarkabel für moderne
Photovoltaikanlagen. Es erfüllt höchste Anforderungen an Sicherheit,
Wetterbeständigkeit und elektrische Belastbarkeit sowohl im Innen- als auch
im Außeneinsatz.
categories:
- Solarkabel
images:
- /uploads/2025/06/H1Z2Z2-K-scaled.webp
application: >
Das H1Z2Z2-K entspricht der Norm DIN EN 50618 (VDE 0283-618) und ist speziell für die
Verkabelung von Photovoltaiksystemen konzipiert. Es kann fest verlegt oder flexibel
geführt werden im Gebäude, im Freien, in Industrieanlagen, landwirtschaftlichen
Betrieben oder sogar in explosionsgefährdeten Bereichen. Die Leitung ist UV-, ozon-
und wasserbeständig (AD7) und darf direkt in der Erde verlegt werden.
locale: de
---
<ProductTabs technicalData={<ProductTechnicalData data={{
"technicalItems": [
{
"label": "Maximal operating conductor temperature (°C)",
"value": "120",
"unit": "°C"
},
{
"label": "Maximal short-circuit temperature (°C)",
"value": "+250 Max. 5 sec.",
"unit": "°C"
},
{
"label": "Minimal temperature for laying (°C)",
"value": "-25",
"unit": "°C"
},
{
"label": "Nennspannung (kV)",
"value": "AC: 1000/1000 V DC: 1500 V",
"unit": "kV"
},
{
"label": "Prüfspannung (kV)",
"value": "6,5 AC, 15 DC (5 min.)",
"unit": "kV"
},
{
"label": "Shape of conductor",
"value": "RM",
"unit": ""
},
{
"label": "Temperaturbereich (°C)",
"value": "-40/+90",
"unit": "°C"
}
],
"voltageTables": [
{
"voltageLabel": "AC: 1000 / 1000 V DC: 1500 V",
"metaItems": [
{
"label": "Spannung",
"value": "AC: 1000 / 1000 V DC: 1500 V"
},
{
"label": "Prüfspannung",
"value": "6,5 AC, 15 DC (5 min.)",
"unit": "kV"
},
{
"label": "Temperaturbereich",
"value": "-40/+90",
"unit": "°C"
},
{
"label": "Leitertemperatur (max.)",
"value": "120",
"unit": "°C"
},
{
"label": "Kurzschlusstemperatur (max.)",
"value": "+250 Max. 5 sec.",
"unit": "°C"
},
{
"label": "Minimale Verlegetemperatur",
"value": "-25",
"unit": "°C"
}
],
"columns": [
{
"key": "Cond",
"label": "Leiter"
},
{
"key": "shape",
"label": "Form"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x1,5",
"cells": [
"",
"RM",
"13,7",
"22",
"4,5",
"33"
]
},
{
"configuration": "1x2,5",
"cells": [
"",
"RM",
"8,21",
"24",
"4,9",
"41"
]
},
{
"configuration": "1x4",
"cells": [
"",
"RM",
"5,09",
"26",
"5,5",
"57"
]
},
{
"configuration": "1x6",
"cells": [
"",
"RM",
"3,39",
"30",
"5,9",
"73"
]
},
{
"configuration": "1x10",
"cells": [
"",
"RM",
"1,95",
"35",
"6,9",
"110"
]
},
{
"configuration": "1x16",
"cells": [
"",
"RM",
"1,24",
"40",
"8",
"170"
]
},
{
"configuration": "1x25",
"cells": [
"",
"RM",
"0,795",
"50",
"10",
"260"
]
},
{
"configuration": "1x35",
"cells": [
"",
"RM",
"0,565",
"56",
"11",
"360"
]
},
{
"configuration": "1x50",
"cells": [
"",
"RM",
"0,393",
"60",
"13,2",
"500"
]
}
]
}
]
}} />}>
<h3>Für dauerhafte Einsätze in anspruchsvollen Umgebungen</h3>
<p>Das <strong>H1Z2Z2-K</strong> entspricht der <strong>Norm DIN EN 50618 (VDE 0283-618)</strong> und ist speziell für die <strong>Verkabelung von Photovoltaiksystemen</strong> konzipiert. Es kann <strong>fest verlegt oder flexibel geführt</strong> werden im Gebäude, im Freien, in Industrieanlagen, landwirtschaftlichen Betrieben oder sogar in <strong>explosionsgefährdeten Bereichen</strong>. Die Leitung ist <strong>UV-, ozon- und wasserbeständig (AD7)</strong> und darf <strong>direkt in der Erde verlegt</strong> werden.</p>
<h3>Aufbau und technische Merkmale</h3>
<p>Der feindrähtige <strong>verzinnt Kupferleiter (Klasse 5)</strong> ist doppelt geschützt durch eine <strong>vernetzte Isolierung und einen vernetzten Außenmantel aus Polyolefincopolymer</strong> halogenfrei, flammwidrig und mit hoher Abriebfestigkeit. Das Kabel ist für eine maximale Leitertemperatur von <strong>120°C</strong> ausgelegt und bleibt auch bei <strong>-40°C (fest verlegt)</strong> zuverlässig flexibel. Die <strong>geringe Rauchentwicklung</strong> und hohe Beständigkeit gegenüber mechanischen und thermischen Einflüssen sorgen für einen sicheren, langjährigen Betrieb.</p>
<h3>Eigenschaften im Überblick</h3>
<ul>
<li>
<p><strong>Halogenfrei, flammwidrig, UV- und ozonbeständig</strong></p>
</li>
<li>
<p><strong>Kurzschluss- und erdschlusssicher gemäß VDE-AR-E 2283-4</strong></p>
</li>
<li>
<p><strong>Zugelassen für Innenräume, Außenbereiche und explosionsgefährdete Zonen</strong></p>
</li>
<li>
<p><strong>Geeignet für direkte Erdverlegung</strong></p>
</li>
<li>
<p><strong>CPR-Leistungsklasse: Eca</strong></p>
</li>
</ul>
</ProductTabs>