title: H1Z2Z2-K
|
||
sku: H1Z2Z2-K-solar-cables
|
||
description: >
|
||
Das H1Z2Z2-K Kabel ist ein hochflexibles, halogenfreies Solarkabel für moderne
|
||
Photovoltaikanlagen. Es erfüllt höchste Anforderungen an Sicherheit,
|
||
Wetterbeständigkeit und elektrische Belastbarkeit – sowohl im Innen- als auch
|
||
im Außeneinsatz.
|
||
categories:
|
||
- Solarkabel
|
||
images:
|
||
- /uploads/2025/06/H1Z2Z2-K-scaled.webp
|
||
application: >
|
||
Das H1Z2Z2-K entspricht der Norm DIN EN 50618 (VDE 0283-618) und ist speziell für die
|
||
Verkabelung von Photovoltaiksystemen konzipiert. Es kann fest verlegt oder flexibel
|
||
geführt werden – im Gebäude, im Freien, in Industrieanlagen, landwirtschaftlichen
|
||
Betrieben oder sogar in explosionsgefährdeten Bereichen. Die Leitung ist UV-, ozon-
|
||
und wasserbeständig (AD7) und darf direkt in der Erde verlegt werden.
|
||
locale: de
|
||
---
|
||
<ProductTabs technicalData={<ProductTechnicalData data={{
|
||
"technicalItems": [
|
||
{
|
||
"label": "Maximal operating conductor temperature (°C)",
|
||
"value": "120",
|
||
"unit": "°C"
|
||
},
|
||
{
|
||
"label": "Maximal short-circuit temperature (°C)",
|
||
"value": "+250 Max. 5 sec.",
|
||
"unit": "°C"
|
||
},
|
||
{
|
||
"label": "Minimal temperature for laying (°C)",
|
||
"value": "-25",
|
||
"unit": "°C"
|
||
},
|
||
{
|
||
"label": "Nennspannung (kV)",
|
||
"value": "AC: 1000/1000 V DC: 1500 V",
|
||
"unit": "kV"
|
||
},
|
||
{
|
||
"label": "Prüfspannung (kV)",
|
||
"value": "6,5 AC, 15 DC (5 min.)",
|
||
"unit": "kV"
|
||
},
|
||
{
|
||
"label": "Shape of conductor",
|
||
"value": "RM",
|
||
"unit": ""
|
||
},
|
||
{
|
||
"label": "Temperaturbereich (°C)",
|
||
"value": "-40/+90",
|
||
"unit": "°C"
|
||
}
|
||
],
|
||
"voltageTables": [
|
||
{
|
||
"voltageLabel": "AC: 1000 / 1000 V DC: 1500 V",
|
||
"metaItems": [
|
||
{
|
||
"label": "Spannung",
|
||
"value": "AC: 1000 / 1000 V DC: 1500 V"
|
||
},
|
||
{
|
||
"label": "Prüfspannung",
|
||
"value": "6,5 AC, 15 DC (5 min.)",
|
||
"unit": "kV"
|
||
},
|
||
{
|
||
"label": "Temperaturbereich",
|
||
"value": "-40/+90",
|
||
"unit": "°C"
|
||
},
|
||
{
|
||
"label": "Leitertemperatur (max.)",
|
||
"value": "120",
|
||
"unit": "°C"
|
||
},
|
||
{
|
||
"label": "Kurzschlusstemperatur (max.)",
|
||
"value": "+250 Max. 5 sec.",
|
||
"unit": "°C"
|
||
},
|
||
{
|
||
"label": "Minimale Verlegetemperatur",
|
||
"value": "-25",
|
||
"unit": "°C"
|
||
}
|
||
],
|
||
"columns": [
|
||
{
|
||
"key": "Cond",
|
||
"label": "Leiter"
|
||
},
|
||
{
|
||
"key": "shape",
|
||
"label": "Form"
|
||
},
|
||
{
|
||
"key": "RI",
|
||
"label": "RI [Ohm/km]"
|
||
},
|
||
{
|
||
"key": "Rbv",
|
||
"label": "Rbv [mm]"
|
||
},
|
||
{
|
||
"key": "Ø",
|
||
"label": "Ø [mm]"
|
||
},
|
||
{
|
||
"key": "G",
|
||
"label": "G [kg/km]"
|
||
}
|
||
],
|
||
"rows": [
|
||
{
|
||
"configuration": "1x1,5",
|
||
"cells": [
|
||
"",
|
||
"RM",
|
||
"13,7",
|
||
"22",
|
||
"4,5",
|
||
"33"
|
||
]
|
||
},
|
||
{
|
||
"configuration": "1x2,5",
|
||
"cells": [
|
||
"",
|
||
"RM",
|
||
"8,21",
|
||
"24",
|
||
"4,9",
|
||
"41"
|
||
]
|
||
},
|
||
{
|
||
"configuration": "1x4",
|
||
"cells": [
|
||
"",
|
||
"RM",
|
||
"5,09",
|
||
"26",
|
||
"5,5",
|
||
"57"
|
||
]
|
||
},
|
||
{
|
||
"configuration": "1x6",
|
||
"cells": [
|
||
"",
|
||
"RM",
|
||
"3,39",
|
||
"30",
|
||
"5,9",
|
||
"73"
|
||
]
|
||
},
|
||
{
|
||
"configuration": "1x10",
|
||
"cells": [
|
||
"",
|
||
"RM",
|
||
"1,95",
|
||
"35",
|
||
"6,9",
|
||
"110"
|
||
]
|
||
},
|
||
{
|
||
"configuration": "1x16",
|
||
"cells": [
|
||
"",
|
||
"RM",
|
||
"1,24",
|
||
"40",
|
||
"8",
|
||
"170"
|
||
]
|
||
},
|
||
{
|
||
"configuration": "1x25",
|
||
"cells": [
|
||
"",
|
||
"RM",
|
||
"0,795",
|
||
"50",
|
||
"10",
|
||
"260"
|
||
]
|
||
},
|
||
{
|
||
"configuration": "1x35",
|
||
"cells": [
|
||
"",
|
||
"RM",
|
||
"0,565",
|
||
"56",
|
||
"11",
|
||
"360"
|
||
]
|
||
},
|
||
{
|
||
"configuration": "1x50",
|
||
"cells": [
|
||
"",
|
||
"RM",
|
||
"0,393",
|
||
"60",
|
||
"13,2",
|
||
"500"
|
||
]
|
||
}
|
||
]
|
||
}
|
||
]
|
||
}} />}>
|
||
|
||
|
||
<h3>Für dauerhafte Einsätze in anspruchsvollen Umgebungen</h3>
|
||
<p>Das <strong>H1Z2Z2-K</strong> entspricht der <strong>Norm DIN EN 50618 (VDE 0283-618)</strong> und ist speziell für die <strong>Verkabelung von Photovoltaiksystemen</strong> konzipiert. Es kann <strong>fest verlegt oder flexibel geführt</strong> werden – im Gebäude, im Freien, in Industrieanlagen, landwirtschaftlichen Betrieben oder sogar in <strong>explosionsgefährdeten Bereichen</strong>. Die Leitung ist <strong>UV-, ozon- und wasserbeständig (AD7)</strong> und darf <strong>direkt in der Erde verlegt</strong> werden.</p>
|
||
<h3>Aufbau und technische Merkmale</h3>
|
||
<p>Der feindrähtige <strong>verzinnt Kupferleiter (Klasse 5)</strong> ist doppelt geschützt durch eine <strong>vernetzte Isolierung und einen vernetzten Außenmantel aus Polyolefincopolymer</strong> – halogenfrei, flammwidrig und mit hoher Abriebfestigkeit. Das Kabel ist für eine maximale Leitertemperatur von <strong>120 °C</strong> ausgelegt und bleibt auch bei <strong>-40 °C (fest verlegt)</strong> zuverlässig flexibel. Die <strong>geringe Rauchentwicklung</strong> und hohe Beständigkeit gegenüber mechanischen und thermischen Einflüssen sorgen für einen sicheren, langjährigen Betrieb.</p>
|
||
<h3>Eigenschaften im Überblick</h3>
|
||
<ul>
|
||
<li>
|
||
<p><strong>Halogenfrei, flammwidrig, UV- und ozonbeständig</strong></p>
|
||
</li>
|
||
<li>
|
||
<p><strong>Kurzschluss- und erdschlusssicher gemäß VDE-AR-E 2283-4</strong></p>
|
||
</li>
|
||
<li>
|
||
<p><strong>Zugelassen für Innenräume, Außenbereiche und explosionsgefährdete Zonen</strong></p>
|
||
</li>
|
||
<li>
|
||
<p><strong>Geeignet für direkte Erdverlegung</strong></p>
|
||
</li>
|
||
<li>
|
||
<p><strong>CPR-Leistungsklasse: Eca</strong></p>
|
||
</li>
|
||
</ul>
|
||
|
||
|
||
</ProductTabs>
|