Files
klz-cables.com/data/products/de/mittelspannungskabel/na2xsy.mdx
Marc Mintel f7aa880d9f
Some checks failed
Build & Deploy / 🔍 Prepare (push) Successful in 1m19s
Build & Deploy / 🧪 QA (push) Failing after 3m32s
Build & Deploy / 🚀 Deploy (push) Has been skipped
Build & Deploy / 🏗️ Build (push) Failing after 7m51s
Build & Deploy / ⚡ Lighthouse (push) Has been skipped
Build & Deploy / 🧪 Smoke Test (push) Has been skipped
Build & Deploy / ♿ WCAG (push) Has been skipped
Build & Deploy / 🛡️ Quality Gates (push) Has been skipped
Build & Deploy / 🔔 Notify (push) Successful in 10s
feat: migration von directus zu payloadcms
2026-02-24 19:25:43 +01:00

1145 lines
24 KiB
Plaintext
Raw Blame History

This file contains invisible Unicode characters
This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
---
title: NA2XSY
sku: NA2XSY-medium-voltage-cables
description: >
Das NA2XSY Kabel ist ein erdverlegbares Mittelspannungskabel mit
Aluminiumleiter, VPE-Isolation und Kupferschirmung. Es wurde für
anspruchsvolle Energieverteilungen konzipiert und überzeugt durch hohe
Betriebssicherheit, gute Verlegeeigenschaften und thermische Belastbarkeit bis
90°C.
categories:
- Mittelspannungskabel
images:
- /uploads/2025/01/NA2XSY-scaled.webp
application: >
Das NA2XSY erfüllt die Anforderungen der Normen DIN VDE 0276-620, HD 620 S2 und IEC
60502. Es eignet sich für die Verlegung in Innenräumen, Kabelkanälen, im Erdreich, im
Wasser oder im Freien allerdings nur bei geschützter Verlegung. Typische
Einsatzorte sind Industrieanlagen, Kraftwerke und Schaltanlagen, in denen
Mittelspannung mit hoher Betriebssicherheit transportiert werden muss.
locale: de
---
<ProductTabs technicalData={<ProductTechnicalData data={{
"technicalItems": [
{
"label": "CPR class",
"value": "Eca",
"unit": ""
},
{
"label": "Maximal operating conductor temperature (°C)",
"value": "+90",
"unit": "°C"
},
{
"label": "Maximal short-circuit temperature (°C)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimal storage temperature (°C)",
"value": "-25",
"unit": "°C"
},
{
"label": "Minimal temperature for laying (°C)",
"value": "-5",
"unit": "°C"
},
{
"label": "Shape of conductor",
"value": "RM",
"unit": ""
},
{
"label": "Temperaturbereich (°C)",
"value": "-35-+90",
"unit": "°C"
}
],
"voltageTables": [
{
"voltageLabel": "6/10 kV",
"metaItems": [
{
"label": "Spannung",
"value": "6/10 kV"
},
{
"label": "Prüfspannung",
"value": "21",
"unit": "kV"
},
{
"label": "Temperaturbereich",
"value": "-35-+90",
"unit": "°C"
},
{
"label": "Leitertemperatur (max.)",
"value": "+90",
"unit": "°C"
},
{
"label": "Kurzschlusstemperatur (max.)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimale Verlegetemperatur",
"value": "-5",
"unit": "°C"
},
{
"label": "Minimale Lagertemperatur",
"value": "-25",
"unit": "°C"
},
{
"label": "CPR-Klasse",
"value": "Eca",
"unit": ""
},
{
"label": "Flammhemmend",
"value": "EN 60 332-1-2 / EN 60 332-1-3 / EN 60 332-1-4 / EN 60 332-1-5 / EN 60 332-1-6 / EN 60 332-1-7 / EN 60 332-1-8 / EN 60 332-1-9 / EN 60 332-1-10 / EN 60 332-1-11 / EN 60 332-1-12 / EN 60 332-1-13 / EN 60 332-1-14 / EN 60 332-1-15 / EN 60 332-1-16",
"unit": ""
}
],
"columns": [
{
"key": "Cond",
"label": "Leiter"
},
{
"key": "shape",
"label": "Form"
},
{
"key": "cap",
"label": "Cap [uF/km]"
},
{
"key": "DI",
"label": "DI [mm]"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Wi",
"label": "Wi [mm]"
},
{
"key": "Ibl",
"label": "Ibl [A]"
},
{
"key": "Ibe",
"label": "Ibe [A]"
},
{
"key": "Ik_cond",
"label": "Ik [kA]"
},
{
"key": "Wm",
"label": "Wm [mm]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x35/16",
"cells": [
"Al",
"RM",
"0,22",
"15,3",
"0,868",
"3,4",
"153",
"145",
"3,3",
"2,1",
"360",
"24",
"668"
]
},
{
"configuration": "1x50/16",
"cells": [
"Al",
"RM",
"0,25",
"16,4",
"0,641",
"3,4",
"183",
"171",
"4,7",
"2,1",
"375",
"25",
"734"
]
},
{
"configuration": "1x70/16",
"cells": [
"Al",
"RM",
"0,28",
"17,9",
"0,443",
"3,4",
"228",
"208",
"6,6",
"2,1",
"405",
"27",
"824"
]
},
{
"configuration": "1x95/16",
"cells": [
"Al",
"RM",
"0,31",
"19,4",
"0,32",
"3,4",
"278",
"248",
"9",
"2,1",
"420",
"28",
"932"
]
},
{
"configuration": "1x120/16",
"cells": [
"Al",
"RM",
"0,34",
"20,9",
"0,253",
"3,4",
"321",
"283",
"11,3",
"2,1",
"450",
"30",
"1036"
]
},
{
"configuration": "1x150/25",
"cells": [
"Al",
"RM",
"0,37",
"22,3",
"0,206",
"3,4",
"364",
"315",
"14,2",
"2,1",
"465",
"31",
"1222"
]
},
{
"configuration": "1x185/16",
"cells": [
"Al",
"RM",
"0,4",
"23,9",
"0,164",
"3,4",
"418",
"357",
"17,5",
"2,1",
"495",
"33",
"1283"
]
},
{
"configuration": "1x185/25",
"cells": [
"Al",
"RM",
"0,41",
"23,9",
"0,164",
"3,4",
"418",
"357",
"17,5",
"2,1",
"495",
"33",
"1372"
]
},
{
"configuration": "1x240/25",
"cells": [
"Al",
"RM",
"0,44",
"26,2",
"0,125",
"3,4",
"494",
"413",
"22,7",
"2,1",
"525",
"35",
"1579"
]
},
{
"configuration": "1x300/25",
"cells": [
"Al",
"RM",
"0,48",
"28,3",
"0,1",
"3,4",
"568",
"466",
"28,4",
"2,1",
"570",
"38",
"1834"
]
},
{
"configuration": "1x400/35",
"cells": [
"Al",
"RM",
"0,54",
"31,4",
"0,0778",
"3,4",
"660",
"529",
"37,8",
"2,1",
"600",
"40",
"2263"
]
},
{
"configuration": "1x500/35",
"cells": [
"Al",
"RM",
"0,62",
"34,6",
"0,0605",
"3,4",
"767",
"602",
"47,3",
"2,1",
"645",
"43",
"2643"
]
},
{
"configuration": "1x630/35",
"cells": [
"Al",
"RM",
"0,67",
"38",
"0,0469",
"3,4",
"840",
"681",
"59,6",
"2,1",
"705",
"47",
"3120"
]
},
{
"configuration": "1x800/35",
"cells": [
"Al",
"RM",
"0,76",
"42,3",
"0,0367",
"3,4",
"953",
"754",
"75,6",
"2,4",
"765",
"51",
"3760"
]
},
{
"configuration": "1x1000/35",
"cells": [
"Al",
"RM",
"0,84",
"46,2",
"0,0291",
"3,4",
"1187",
"852",
"94",
"2,4",
"855",
"57",
"4724"
]
}
]
},
{
"voltageLabel": "12/20 kV",
"metaItems": [
{
"label": "Spannung",
"value": "12/20 kV"
},
{
"label": "Prüfspannung",
"value": "42",
"unit": "kV"
},
{
"label": "Temperaturbereich",
"value": "-35-+90",
"unit": "°C"
},
{
"label": "Leitertemperatur (max.)",
"value": "+90",
"unit": "°C"
},
{
"label": "Kurzschlusstemperatur (max.)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimale Verlegetemperatur",
"value": "-5",
"unit": "°C"
},
{
"label": "Minimale Lagertemperatur",
"value": "-25",
"unit": "°C"
},
{
"label": "CPR-Klasse",
"value": "Eca",
"unit": ""
},
{
"label": "Flammhemmend",
"value": "EN 60 332-1-2",
"unit": ""
}
],
"columns": [
{
"key": "Cond",
"label": "Leiter"
},
{
"key": "shape",
"label": "Form"
},
{
"key": "cap",
"label": "Cap [uF/km]"
},
{
"key": "DI",
"label": "DI [mm]"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Wi",
"label": "Wi [mm]"
},
{
"key": "Ibl",
"label": "Ibl [A]"
},
{
"key": "Ibe",
"label": "Ibe [A]"
},
{
"key": "Ik_cond",
"label": "Ik [kA]"
},
{
"key": "Wm",
"label": "Wm [mm]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x50/16",
"cells": [
"Al",
"RM",
"0,17",
"20,5",
"0,641",
"5,5",
"185",
"172",
"4,7",
"2,1",
"435",
"29",
"936"
]
},
{
"configuration": "1x70/16",
"cells": [
"Al",
"RM",
"0,19",
"22",
"0,443",
"5,5",
"231",
"210",
"6,6",
"2,1",
"465",
"31",
"1037"
]
},
{
"configuration": "1x95/16",
"cells": [
"Al",
"RM",
"0,21",
"23,5",
"0,32",
"5,5",
"280",
"251",
"9",
"2,1",
"480",
"32",
"1157"
]
},
{
"configuration": "1x120/16",
"cells": [
"Al",
"RM",
"0,23",
"25",
"0,253",
"5,5",
"323",
"285",
"11,3",
"2,1",
"510",
"34",
"1274"
]
},
{
"configuration": "1x150/25",
"cells": [
"Al",
"RM",
"0,25",
"26,4",
"0,206",
"5,5",
"366",
"319",
"14,2",
"2,1",
"540",
"36",
"1491"
]
},
{
"configuration": "1x185/16",
"cells": [
"Al",
"RM",
"0,27",
"28",
"0,164",
"5,5",
"420",
"361",
"17,5",
"2,1",
"555",
"37",
"1546"
]
},
{
"configuration": "1x185/25",
"cells": [
"Al",
"RM",
"0,27",
"28",
"0,164",
"5,5",
"420",
"361",
"17,5",
"2,1",
"555",
"37",
"1636"
]
},
{
"configuration": "1x240/25",
"cells": [
"Al",
"RM",
"0,3",
"30,3",
"0,125",
"5,5",
"496",
"417",
"22,7",
"2,1",
"585",
"39",
"1863"
]
},
{
"configuration": "1x300/25",
"cells": [
"Al",
"RM",
"0,32",
"32,4",
"0,1",
"5,5",
"569",
"471",
"28,4",
"2,1",
"615",
"41",
"2084"
]
},
{
"configuration": "1x400/35",
"cells": [
"Al",
"RM",
"0,36",
"35,5",
"0,0778",
"5,5",
"660",
"535",
"37,8",
"2,1",
"660",
"44",
"2567"
]
},
{
"configuration": "1x500/35",
"cells": [
"Al",
"RM",
"0,4",
"38,7",
"0,0605",
"5,5",
"766",
"609",
"47,3",
"2,1",
"720",
"48",
"2992"
]
},
{
"configuration": "1x630/35",
"cells": [
"Al",
"RM",
"0,44",
"42,1",
"0,0469",
"5,5",
"866",
"697",
"59,6",
"2,4",
"765",
"51",
"3520"
]
},
{
"configuration": "1x800/35",
"cells": [
"Al",
"RM",
"0,49",
"46,4",
"0,0367",
"5,5",
"1000",
"780",
"75,6",
"2,4",
"840",
"56",
"4182"
]
},
{
"configuration": "1x1000/35",
"cells": [
"Al",
"RM",
"0,54",
"50,3",
"0,0291",
"5,5",
"1130",
"868",
"94,6",
"2,4",
"915",
"61",
"5165"
]
}
]
},
{
"voltageLabel": "18/30 kV",
"metaItems": [
{
"label": "Spannung",
"value": "18/30 kV"
},
{
"label": "Prüfspannung",
"value": "63",
"unit": "kV"
},
{
"label": "Temperaturbereich",
"value": "-35-+90",
"unit": "°C"
},
{
"label": "Leitertemperatur (max.)",
"value": "+90",
"unit": "°C"
},
{
"label": "Kurzschlusstemperatur (max.)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimale Verlegetemperatur",
"value": "-5",
"unit": "°C"
},
{
"label": "Minimale Lagertemperatur",
"value": "-25",
"unit": "°C"
},
{
"label": "CPR-Klasse",
"value": "Eca",
"unit": ""
},
{
"label": "Flammhemmend",
"value": "EN 60 332-1-2",
"unit": ""
}
],
"columns": [
{
"key": "Cond",
"label": "Leiter"
},
{
"key": "shape",
"label": "Form"
},
{
"key": "cap",
"label": "Cap [uF/km]"
},
{
"key": "DI",
"label": "DI [mm]"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Wi",
"label": "Wi [mm]"
},
{
"key": "Ibl",
"label": "Ibl [A]"
},
{
"key": "Ibe",
"label": "Ibe [A]"
},
{
"key": "Ik_cond",
"label": "Ik [kA]"
},
{
"key": "Wm",
"label": "Wm [mm]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x50/16",
"cells": [
"Al",
"RM",
"0,13",
"25,5",
"0,641",
"8",
"187",
"174",
"4,7",
"2,1",
"510",
"34",
"1176"
]
},
{
"configuration": "1x70/16",
"cells": [
"Al",
"RM",
"0,15",
"27",
"0,443",
"8",
"232",
"213",
"6,6",
"2,1",
"540",
"36",
"1290"
]
},
{
"configuration": "1x95/16",
"cells": [
"Al",
"RM",
"0,16",
"28,5",
"0,32",
"8",
"282",
"254",
"9",
"2,1",
"555",
"37",
"1421"
]
},
{
"configuration": "1x120/16",
"cells": [
"Al",
"RM",
"0,17",
"30",
"0,253",
"8",
"325",
"289",
"11,3",
"2,1",
"585",
"39",
"1548"
]
},
{
"configuration": "1x150/25",
"cells": [
"Al",
"RM",
"0,19",
"31,4",
"0,206",
"8",
"367",
"322",
"14,2",
"2,1",
"600",
"40",
"1757"
]
},
{
"configuration": "1x185/25",
"cells": [
"Al",
"RM",
"0,2",
"33",
"0,164",
"8",
"421",
"364",
"17,5",
"2,1",
"630",
"42",
"1930"
]
},
{
"configuration": "1x240/25",
"cells": [
"Al",
"RM",
"0,22",
"35,3",
"0,125",
"8",
"496",
"422",
"22,7",
"2,1",
"660",
"44",
"2172"
]
},
{
"configuration": "1x300/25",
"cells": [
"Al",
"RM",
"0,24",
"37,4",
"0,1",
"8",
"568",
"476",
"28,4",
"2,1",
"690",
"46",
"2424"
]
},
{
"configuration": "1x400/35",
"cells": [
"Al",
"RM",
"0,27",
"40,5",
"0,0778",
"8",
"659",
"541",
"37,8",
"2,1",
"735",
"49",
"2928"
]
},
{
"configuration": "1x500/35",
"cells": [
"Al",
"RM",
"0,29",
"43,7",
"0,0605",
"8",
"764",
"616",
"47,3",
"2,4",
"795",
"53",
"3390"
]
},
{
"configuration": "1x630/35",
"cells": [
"Al",
"RM",
"0,32",
"47,1",
"0,0469",
"8",
"877",
"702",
"59,6",
"2,4",
"840",
"56",
"3937"
]
},
{
"configuration": "1x800/35",
"cells": [
"Al",
"RM",
"0,36",
"51,4",
"0,0367",
"8",
"1000",
"780",
"75,6",
"2,9",
"915",
"61",
"4667"
]
},
{
"configuration": "1x1000/35",
"cells": [
"Al",
"RM",
"0,39",
"55,3",
"0,0291",
"8",
"1142",
"877",
"94,6",
"3",
"1005",
"67",
"5703"
]
}
]
}
]
}} />}>
<h3>Für leistungsstarke Mittelspannungsnetze</h3>
<p>Das <strong>NA2XSY</strong> erfüllt die Anforderungen der Normen <strong>DIN VDE 0276-620</strong>, <strong>HD 620 S2</strong> und <strong>IEC 60502</strong>. Es eignet sich für die <strong>Verlegung in Innenräumen, Kabelkanälen, im Erdreich, im Wasser oder im Freien</strong> allerdings nur bei geschützter Verlegung. Typische Einsatzorte sind <strong>Industrieanlagen, Kraftwerke und Schaltanlagen</strong>, in denen Mittelspannung mit hoher Betriebssicherheit transportiert werden muss.</p>
<h3>Technischer Aufbau</h3>
<p>Der Leiter besteht aus <strong>mehrdrähtigem Aluminium</strong> (Kl.2 nach VDE 0295 / IEC 60228). Die <strong>VPE-Isolierung</strong> ist dauerhaft mit der <strong>äußeren Leitschicht</strong> verbunden, um eine <strong>teilentladungsfreie Struktur</strong> zu gewährleisten. Der Aufbau umfasst außerdem eine <strong>innere Leitschicht</strong>, <strong>leitfähige Bandierung</strong>, eine <strong>Cu-Abschirmung mit Querleitwendeln</strong>, zusätzliche Bandierung sowie einen <strong>roten PVC-Mantel</strong>. Das Kabel ist flammwidrig und für <strong>Erdverlegung freigegeben</strong> (je nach Typ).</p>
<h3>Anwendung und Eigenschaften</h3>
<p>Dank seines präzisen Aufbaus lässt sich das NA2XSY auch bei komplexer Trassenführung gut verlegen. Es ist <strong>silikon- und cadmiumfrei</strong>, enthält keine lackbenetzungsstörenden Stoffe und hält <strong>Kurzschlusstemperaturen bis +250°C</strong> stand. Der konzentrische Aufbau und die festhaftenden Leitschichten machen dieses Kabel zur <strong>zuverlässigen Lösung für mittelspannungsgeführte Energieverteilungen</strong>, bei denen Betriebssicherheit und Montagefreundlichkeit entscheidend sind.</p>
</ProductTabs>