Files
klz-cables.com/data/products/de/mittelspannungskabel/n2xs2y.mdx
Marc Mintel f7aa880d9f
Some checks failed
Build & Deploy / 🔍 Prepare (push) Successful in 1m19s
Build & Deploy / 🧪 QA (push) Failing after 3m32s
Build & Deploy / 🚀 Deploy (push) Has been skipped
Build & Deploy / 🏗️ Build (push) Failing after 7m51s
Build & Deploy / ⚡ Lighthouse (push) Has been skipped
Build & Deploy / 🧪 Smoke Test (push) Has been skipped
Build & Deploy / ♿ WCAG (push) Has been skipped
Build & Deploy / 🛡️ Quality Gates (push) Has been skipped
Build & Deploy / 🔔 Notify (push) Successful in 10s
feat: migration von directus zu payloadcms
2026-02-24 19:25:43 +01:00

969 lines
20 KiB
Plaintext
Raw Blame History

This file contains invisible Unicode characters
This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
---
title: N2XS2Y
sku: N2XS2Y-medium-voltage-cables
description: >
Das N2XS2Y Kabel ist ein robustes Mittelspannungskabel mit Kupferleiter,
VPE-Isolation und widerstandsfähigem PE-Mantel. Es bietet eine zuverlässige
Energieübertragung selbst bei hoher mechanischer Belastung und anspruchsvollen
Umweltbedingungen.
categories:
- Mittelspannungskabel
images:
- /uploads/2025/01/N2XS2Y-scaled.webp
application: >
Das N2XS2Y erfüllt die Normen DIN VDE 0276-620, HD 620 S2 und IEC 60502. Es eignet sich
zur Verlegung in Innenräumen, Kabelkanälen, im Freien, im Wasser, auf Kabelpritschen
und insbesondere im Erdreich. Aufgrund seines widerstandsfähigen Mantels wird es
häufig in Industrieanlagen, Kraftwerken und Schaltstationen eingesetzt, wo Stabilität
und Langlebigkeit gefordert sind.
locale: de
---
<ProductTabs technicalData={<ProductTechnicalData data={{
"technicalItems": [
{
"label": "CPR class",
"value": "Fca",
"unit": ""
},
{
"label": "Flame retardant",
"value": "no",
"unit": ""
},
{
"label": "Maximal operating conductor temperature (°C)",
"value": "+90",
"unit": "°C"
},
{
"label": "Maximal short-circuit temperature (°C)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimal storage temperature (°C)",
"value": "-35",
"unit": "°C"
},
{
"label": "Minimal temperature for laying (°C)",
"value": "-20",
"unit": "°C"
},
{
"label": "Shape of conductor",
"value": "RM",
"unit": ""
},
{
"label": "Temperaturbereich (°C)",
"value": "-35-+90",
"unit": "°C"
}
],
"voltageTables": [
{
"voltageLabel": "6/10 kV",
"metaItems": [
{
"label": "Spannung",
"value": "6/10 kV"
},
{
"label": "Prüfspannung",
"value": "21",
"unit": "kV"
},
{
"label": "Temperaturbereich",
"value": "-35-+90",
"unit": "°C"
},
{
"label": "Leitertemperatur (max.)",
"value": "+90",
"unit": "°C"
},
{
"label": "Kurzschlusstemperatur (max.)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimale Verlegetemperatur",
"value": "-20",
"unit": "°C"
},
{
"label": "Minimale Lagertemperatur",
"value": "-35",
"unit": "°C"
},
{
"label": "CPR-Klasse",
"value": "Fca",
"unit": ""
},
{
"label": "Flammhemmend",
"value": "no",
"unit": ""
}
],
"columns": [
{
"key": "Cond",
"label": "Leiter"
},
{
"key": "shape",
"label": "Form"
},
{
"key": "cap",
"label": "Cap [uF/km]"
},
{
"key": "DI",
"label": "DI [mm]"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Wi",
"label": "Wi [mm]"
},
{
"key": "Ibl",
"label": "Ibl [A]"
},
{
"key": "Ibe",
"label": "Ibe [A]"
},
{
"key": "Ik_cond",
"label": "Ik [kA]"
},
{
"key": "Wm",
"label": "Wm [mm]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x35/16",
"cells": [
"Cu",
"RM",
"0,22",
"15,3",
"0,524",
"3,4",
"197",
"187",
"5",
"2,1",
"360",
"24",
"803"
]
},
{
"configuration": "1x50/16",
"cells": [
"Cu",
"RM",
"0,24",
"16,3",
"0,387",
"3,4",
"238",
"220",
"7,1",
"2,1",
"375",
"25",
"928"
]
},
{
"configuration": "1x70/16",
"cells": [
"Cu",
"RM",
"0,28",
"17,9",
"0,268",
"3,4",
"294",
"268",
"10",
"2,1",
"390",
"26",
"1154"
]
},
{
"configuration": "1x95/16",
"cells": [
"Cu",
"RM",
"0,3",
"19,4",
"0,193",
"3,4",
"358",
"320",
"13,6",
"2,1",
"420",
"28",
"1410"
]
},
{
"configuration": "1x120/16",
"cells": [
"Cu",
"RM",
"0,34",
"20,9",
"0,153",
"3,4",
"413",
"363",
"17,1",
"2,1",
"450",
"30",
"1682"
]
},
{
"configuration": "1x150/25",
"cells": [
"Cu",
"RM",
"0,36",
"22,3",
"0,124",
"3,4",
"468",
"405",
"21,4",
"2,1",
"465",
"31",
"2025"
]
},
{
"configuration": "1x185/25",
"cells": [
"Cu",
"RM",
"0,4",
"23,9",
"0,099",
"3,4",
"535",
"456",
"26,4",
"2,1",
"480",
"32",
"2383"
]
},
{
"configuration": "1x240/25",
"cells": [
"Cu",
"RM",
"0,44",
"26,4",
"0,075",
"3,4",
"631",
"526",
"34,3",
"2,1",
"525",
"35",
"2965"
]
},
{
"configuration": "1x300/25",
"cells": [
"Cu",
"RM",
"0,49",
"28,8",
"0,06",
"3,4",
"722",
"591",
"42,9",
"2,1",
"555",
"37",
"3624"
]
},
{
"configuration": "1x400/35",
"cells": [
"Cu",
"RM",
"0,54",
"31,4",
"0,047",
"3,4",
"827",
"662",
"57,2",
"2,1",
"600",
"40",
"4574"
]
},
{
"configuration": "1x500/35",
"cells": [
"Cu",
"RM",
"0,61",
"34,6",
"0,037",
"3,4",
"949",
"744",
"71,4",
"2,1",
"645",
"43",
"5597"
]
}
]
},
{
"voltageLabel": "12/20 kV",
"metaItems": [
{
"label": "Spannung",
"value": "12/20 kV"
},
{
"label": "Prüfspannung",
"value": "42",
"unit": "kV"
},
{
"label": "Temperaturbereich",
"value": "-35-+90",
"unit": "°C"
},
{
"label": "Leitertemperatur (max.)",
"value": "+90",
"unit": "°C"
},
{
"label": "Kurzschlusstemperatur (max.)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimale Verlegetemperatur",
"value": "-20",
"unit": "°C"
},
{
"label": "Minimale Lagertemperatur",
"value": "-35",
"unit": "°C"
},
{
"label": "CPR-Klasse",
"value": "Fca",
"unit": ""
},
{
"label": "Flammhemmend",
"value": "no",
"unit": ""
}
],
"columns": [
{
"key": "Cond",
"label": "Leiter"
},
{
"key": "shape",
"label": "Form"
},
{
"key": "cap",
"label": "Cap [uF/km]"
},
{
"key": "DI",
"label": "DI [mm]"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Wi",
"label": "Wi [mm]"
},
{
"key": "Ibl",
"label": "Ibl [A]"
},
{
"key": "Ibe",
"label": "Ibe [A]"
},
{
"key": "Ik_cond",
"label": "Ik [kA]"
},
{
"key": "Wm",
"label": "Wm [mm]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x35/16",
"cells": [
"Cu",
"RM",
"0,16",
"19,5",
"0,524",
"5,5",
"200",
"189",
"5",
"2,1",
"420",
"28",
"948"
]
},
{
"configuration": "1x50/16",
"cells": [
"Cu",
"RM",
"0,17",
"20,5",
"0,387",
"5,5",
"239",
"222",
"7,1",
"2,1",
"435",
"29",
"1078"
]
},
{
"configuration": "1x70/16",
"cells": [
"Cu",
"RM",
"0,19",
"22,1",
"0,268",
"5,5",
"297",
"271",
"10",
"2,1",
"465",
"31",
"1315"
]
},
{
"configuration": "1x95/16",
"cells": [
"Cu",
"RM",
"0,21",
"23,6",
"0,193",
"5,5",
"361",
"323",
"13,6",
"2,1",
"480",
"32",
"1579"
]
},
{
"configuration": "1x120/16",
"cells": [
"Cu",
"RM",
"0,23",
"25,1",
"0,153",
"5,5",
"416",
"367",
"17,1",
"2,1",
"510",
"34",
"1861"
]
},
{
"configuration": "1x150/25",
"cells": [
"Cu",
"RM",
"0,25",
"26,5",
"0,124",
"5,5",
"470",
"409",
"21,4",
"2,1",
"525",
"35",
"2212"
]
},
{
"configuration": "1x185/25",
"cells": [
"Cu",
"RM",
"0,27",
"28,1",
"0,099",
"5,5",
"538",
"461",
"26,4",
"2,1",
"555",
"37",
"2585"
]
},
{
"configuration": "1x240/25",
"cells": [
"Cu",
"RM",
"0,3",
"30,6",
"0,075",
"5,5",
"634",
"532",
"34,3",
"2,1",
"585",
"39",
"3181"
]
},
{
"configuration": "1x300/25",
"cells": [
"Cu",
"RM",
"0,33",
"33",
"0,06",
"5,5",
"724",
"599",
"42,9",
"2,1",
"630",
"42",
"3763"
]
},
{
"configuration": "1x400/35",
"cells": [
"Cu",
"RM",
"0,36",
"35,6",
"0,047",
"5,5",
"829",
"671",
"57,2",
"2,1",
"660",
"44",
"4795"
]
},
{
"configuration": "1x500/35",
"cells": [
"Cu",
"RM",
"0,43",
"38,8",
"0,037",
"5,5",
"953",
"754",
"71,4",
"2,1",
"705",
"47",
"5872"
]
}
]
},
{
"voltageLabel": "18/30 kV",
"metaItems": [
{
"label": "Spannung",
"value": "18/30 kV"
},
{
"label": "Prüfspannung",
"value": "63",
"unit": "kV"
},
{
"label": "Temperaturbereich",
"value": "-35-+90",
"unit": "°C"
},
{
"label": "Leitertemperatur (max.)",
"value": "+90",
"unit": "°C"
},
{
"label": "Kurzschlusstemperatur (max.)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimale Verlegetemperatur",
"value": "-20",
"unit": "°C"
},
{
"label": "Minimale Lagertemperatur",
"value": "-35",
"unit": "°C"
},
{
"label": "CPR-Klasse",
"value": "Fca",
"unit": ""
},
{
"label": "Flammhemmend",
"value": "no",
"unit": ""
}
],
"columns": [
{
"key": "Cond",
"label": "Leiter"
},
{
"key": "shape",
"label": "Form"
},
{
"key": "cap",
"label": "Cap [uF/km]"
},
{
"key": "DI",
"label": "DI [mm]"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Wi",
"label": "Wi [mm]"
},
{
"key": "Ibl",
"label": "Ibl [A]"
},
{
"key": "Ibe",
"label": "Ibe [A]"
},
{
"key": "Ik_cond",
"label": "Ik [kA]"
},
{
"key": "Wm",
"label": "Wm [mm]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x50/16",
"cells": [
"Cu",
"RM",
"0,13",
"25,5",
"0,387",
"8",
"241",
"225",
"7,1",
"2,1",
"510",
"34",
"1292"
]
},
{
"configuration": "1x70/16",
"cells": [
"Cu",
"RM",
"0,15",
"27,1",
"0,268",
"8",
"299",
"274",
"10",
"2,1",
"540",
"36",
"1542"
]
},
{
"configuration": "1x95/16",
"cells": [
"Cu",
"RM",
"0,16",
"28,6",
"0,193",
"8",
"363",
"327",
"13,6",
"2,1",
"555",
"37",
"1817"
]
},
{
"configuration": "1x120/16",
"cells": [
"Cu",
"RM",
"0,17",
"30,1",
"0,153",
"8",
"418",
"371",
"17,1",
"2,1",
"585",
"39",
"2110"
]
},
{
"configuration": "1x150/25",
"cells": [
"Cu",
"RM",
"0,19",
"31,5",
"0,124",
"8",
"472",
"414",
"21,4",
"2,1",
"600",
"40",
"2473"
]
},
{
"configuration": "1x185/25",
"cells": [
"Cu",
"RM",
"0,2",
"33,1",
"0,099",
"8",
"539",
"466",
"26,4",
"2,1",
"630",
"42",
"2853"
]
},
{
"configuration": "1x240/25",
"cells": [
"Cu",
"RM",
"0,22",
"35,6",
"0,075",
"8",
"635",
"539",
"34,3",
"2,1",
"660",
"44",
"3467"
]
},
{
"configuration": "1x300/25",
"cells": [
"Cu",
"RM",
"0,24",
"38",
"0,06",
"8",
"725",
"606",
"42,9",
"2,1",
"705",
"47",
"4164"
]
},
{
"configuration": "1x400/35",
"cells": [
"Cu",
"RM",
"0,26",
"40,6",
"0,047",
"8",
"831",
"680",
"57,2",
"2,1",
"735",
"49",
"5131"
]
},
{
"configuration": "1x500/35",
"cells": [
"Cu",
"RM",
"0,29",
"43,8",
"0,037",
"8",
"953",
"765",
"71,4",
"2,4",
"795",
"53",
"6234"
]
}
]
}
]
}} />}>
<h3>Für Erdverlegung und anspruchsvolle Umgebungen</h3>
<p>Das <strong>N2XS2Y</strong> erfüllt die Normen <strong>DIN VDE 0276-620</strong>, <strong>HD 620 S2</strong> und <strong>IEC 60502</strong>. Es eignet sich zur <strong>Verlegung in Innenräumen, Kabelkanälen, im Freien, im Wasser, auf Kabelpritschen und insbesondere im Erdreich</strong>. Aufgrund seines widerstandsfähigen Mantels wird es häufig in <strong>Industrieanlagen, Kraftwerken und Schaltstationen</strong> eingesetzt, wo Stabilität und Langlebigkeit gefordert sind.</p>
<h3>Technischer Aufbau</h3>
<p>Der Leiter besteht aus <strong>blankem, mehrdrähtigem Kupfer</strong> (Klasse2), umgeben von einer <strong>inneren Leitschicht</strong> und einer <strong>VPE-Isolierung</strong> mit festhaftender äußerer Leitschicht. Die Abschirmung erfolgt über eine <strong>Kupferdraht-Umspinnung mit Querleitwendeln</strong>. Zusätzlich ist das Kabel mit einer <strong>leitfähigen Bandierung</strong> versehen und besitzt einen <strong>schwarzen PE-Mantel</strong> (Typ DMP2), der vor Feuchtigkeit und mechanischem Abrieb schützt.</p>
<h3>Merkmale und Einsatzvorteile</h3>
<p>Das N2XS2Y ist <strong>erdverlegbar</strong>, <strong>silikon- und cadmiumfrei</strong> sowie <strong>nicht flammwidrig</strong>. Es ist für Temperaturen bis <strong>+90°C im Betrieb</strong> und <strong>+250°C im Kurzschlussfall</strong> ausgelegt. Dank seines <strong>teilentladungsfreien Aufbaus</strong> bietet es ein hohes Maß an Sicherheit und ist besonders gut für Netze mit hoher Belastung und schwieriger Trassenführung geeignet.</p>
</ProductTabs>