Some checks failed
Build & Deploy / 🔍 Prepare (push) Successful in 1m19s
Build & Deploy / 🧪 QA (push) Failing after 3m32s
Build & Deploy / 🚀 Deploy (push) Has been skipped
Build & Deploy / 🏗️ Build (push) Failing after 7m51s
Build & Deploy / ⚡ Lighthouse (push) Has been skipped
Build & Deploy / 🧪 Smoke Test (push) Has been skipped
Build & Deploy / ♿ WCAG (push) Has been skipped
Build & Deploy / 🛡️ Quality Gates (push) Has been skipped
Build & Deploy / 🔔 Notify (push) Successful in 10s
236 lines
6.2 KiB
Plaintext
236 lines
6.2 KiB
Plaintext
---
|
||
title: N2X(F)KLD2Y
|
||
sku: N2X(F)KLD2Y-high-voltage-cables-2
|
||
description: >
|
||
Das N2X(F)KLD2Y-Hochspannungskabel der Serie 2 ist für Spannungsklassen von
|
||
64/110kV ausgelegt und verwendet hochleitfähige Kupferleiter, ideal für
|
||
industrielle Hochspannungsanwendungen mit anspruchsvollen
|
||
Umgebungsbedingungen.
|
||
categories:
|
||
- Hochspannungskabel
|
||
images: []
|
||
application: >
|
||
Die N2X(F)KLD2Y-Hochspannungskabel Serie 2 sind speziell für den Einsatz in
|
||
Hochspannungsanwendungen konzipiert, wobei sie eine optimale Leistung durch die
|
||
Verwendung von hochleitfähigen Kupferleitern und einer fortschrittlichen
|
||
XLPE-Isolierung bieten. Diese Kabelserie ist besonders geeignet für anspruchsvolle
|
||
industrielle Umgebungen, wo hohe Durchschlagsfestigkeit und
|
||
Thermozyklierungsfähigkeit erforderlich sind.
|
||
locale: de
|
||
---
|
||
<ProductTabs technicalData={<ProductTechnicalData data={{
|
||
"technicalItems": [
|
||
{
|
||
"label": "Nennspannung (kV)",
|
||
"value": "64/110",
|
||
"unit": "kV"
|
||
}
|
||
],
|
||
"voltageTables": [
|
||
{
|
||
"voltageLabel": "64/110 kV",
|
||
"metaItems": [
|
||
{
|
||
"label": "Spannung",
|
||
"value": "64/110 kV"
|
||
}
|
||
],
|
||
"columns": [
|
||
{
|
||
"key": "Cond",
|
||
"label": "Leiter"
|
||
},
|
||
{
|
||
"key": "RI",
|
||
"label": "RI [Ohm/km]"
|
||
},
|
||
{
|
||
"key": "Wi",
|
||
"label": "Wi [mm]"
|
||
},
|
||
{
|
||
"key": "Rbv",
|
||
"label": "Rbv [mm]"
|
||
},
|
||
{
|
||
"key": "Ø",
|
||
"label": "Ø [mm]"
|
||
},
|
||
{
|
||
"key": "G",
|
||
"label": "G [kg/km]"
|
||
}
|
||
],
|
||
"rows": [
|
||
{
|
||
"configuration": "1×240RM",
|
||
"cells": [
|
||
"Cu",
|
||
"0,1",
|
||
"16,5",
|
||
"2,2",
|
||
"86",
|
||
"7040"
|
||
]
|
||
},
|
||
{
|
||
"configuration": "1×300RM",
|
||
"cells": [
|
||
"Cu",
|
||
"0,08",
|
||
"15,5",
|
||
"2,2",
|
||
"86",
|
||
"7550"
|
||
]
|
||
},
|
||
{
|
||
"configuration": "1×400RM",
|
||
"cells": [
|
||
"Cu",
|
||
"0,06",
|
||
"14,5",
|
||
"2,2",
|
||
"88",
|
||
"8380"
|
||
]
|
||
},
|
||
{
|
||
"configuration": "1×500RM",
|
||
"cells": [
|
||
"Cu",
|
||
"0,05",
|
||
"14",
|
||
"2,2",
|
||
"91",
|
||
"9530"
|
||
]
|
||
},
|
||
{
|
||
"configuration": "1×630RM",
|
||
"cells": [
|
||
"Cu",
|
||
"0,04",
|
||
"14",
|
||
"2,4",
|
||
"95",
|
||
"11190"
|
||
]
|
||
},
|
||
{
|
||
"configuration": "1×800RM",
|
||
"cells": [
|
||
"Cu",
|
||
"0,03",
|
||
"14",
|
||
"2,5",
|
||
"100",
|
||
"13160"
|
||
]
|
||
},
|
||
{
|
||
"configuration": "1×1000RM",
|
||
"cells": [
|
||
"Cu",
|
||
"0,03",
|
||
"14",
|
||
"2,6",
|
||
"104",
|
||
"15380"
|
||
]
|
||
},
|
||
{
|
||
"configuration": "1×1200RMS",
|
||
"cells": [
|
||
"Cu",
|
||
"0,02",
|
||
"14",
|
||
"2,8",
|
||
"110",
|
||
"17790"
|
||
]
|
||
},
|
||
{
|
||
"configuration": "1×1400RMS",
|
||
"cells": [
|
||
"Cu",
|
||
"0,02",
|
||
"14",
|
||
"2,9",
|
||
"115",
|
||
"19870"
|
||
]
|
||
},
|
||
{
|
||
"configuration": "1×1600RMS",
|
||
"cells": [
|
||
"Cu",
|
||
"0,02",
|
||
"14",
|
||
"3",
|
||
"119",
|
||
"22210"
|
||
]
|
||
},
|
||
{
|
||
"configuration": "1×1800RMS",
|
||
"cells": [
|
||
"Cu",
|
||
"0,02",
|
||
"14",
|
||
"3,1",
|
||
"122",
|
||
"24720"
|
||
]
|
||
},
|
||
{
|
||
"configuration": "1×2000RMS",
|
||
"cells": [
|
||
"Cu",
|
||
"0,02",
|
||
"14",
|
||
"3,1",
|
||
"124",
|
||
"26340"
|
||
]
|
||
},
|
||
{
|
||
"configuration": "1×2500RMS",
|
||
"cells": [
|
||
"Cu",
|
||
"0,01",
|
||
"14,5",
|
||
"3,3",
|
||
"134",
|
||
"31880"
|
||
]
|
||
}
|
||
]
|
||
}
|
||
]
|
||
}} />}>
|
||
|
||
|
||
<h2>Technische Übersicht</h2>
|
||
<p>Die <strong>N2X(F)KLD2Y-Hochspannungskabel Serie 2</strong> sind speziell für den Einsatz in Hochspannungsanwendungen konzipiert, wobei sie eine optimale Leistung durch die Verwendung von hochleitfähigen Kupferleitern und einer fortschrittlichen XLPE-Isolierung bieten. Diese Kabelserie ist besonders geeignet für anspruchsvolle industrielle Umgebungen, wo hohe Durchschlagsfestigkeit und Thermozyklierungsfähigkeit erforderlich sind.</p>
|
||
|
||
|
||
<h2>Technische Leistung und Konstruktion</h2>
|
||
<p>Die Kabel der Serie N2X(F)KLD2Y sind für ihre hohe <strong>Strombelastbarkeit</strong> und ausgezeichnete <strong>Kurzschlussstromfestigkeit</strong> bekannt. Die spezielle Konstruktion mit Kupferleitern und XLPE-Isolierung sorgt für eine hohe <strong>Durchschlagsfestigkeit</strong> und verbesserte <strong>thermische Eigenschaften</strong>, was sie ideal für den Einsatz in Hochspannungsnetzen macht.</p>
|
||
<ul>
|
||
<li>Verwendung von hochleitfähigem Kupfer für verbesserte elektrische Leistung</li>
|
||
<li>XLPE-Isolierung bietet erhöhte thermische Beständigkeit und Langlebigkeit</li>
|
||
<li>Entwickelt für Installationen in <strong>Kleeblattformation</strong>, <strong>Erdverlegung</strong> und auf <strong>Kabeltrassen</strong></li>
|
||
</ul>
|
||
|
||
|
||
<h2>EMV und Normkonformität</h2>
|
||
<p>Die Kabelserie erfüllt strenge Anforderungen an die <strong>elektromagnetische Verträglichkeit</strong> (EMV), minimiert Spannungsinduzierungen und sorgt für eine zuverlässige Funktion in elektromagnetisch anspruchsvollen Umgebungen. Die Einhaltung der <strong>IEC-Normen</strong>, <strong>CPR-Klassifizierung</strong> und die <strong>CE-Kennzeichnung</strong> bestätigen die hohe Qualität und Sicherheit dieser Kabelserie.</p>
|
||
<ul>
|
||
<li>Konformität mit internationalen und europäischen Standards für Sicherheit und Leistung</li>
|
||
<li>Optimierte Abschirmtechniken zur Reduzierung von elektromagnetischen Störungen</li>
|
||
</ul>
|
||
|
||
|
||
</ProductTabs>
|