Files
klz-cables.com/data/products/de/na2xsfl2y-hv.mdx
Marc Mintel d5dba2be17
All checks were successful
Build & Deploy / 🔍 Prepare (push) Successful in 10s
Build & Deploy / 🧪 QA (push) Successful in 1m11s
Build & Deploy / 🏗️ Build (push) Successful in 2m17s
Build & Deploy / 🚀 Deploy (push) Successful in 15s
Build & Deploy / 🧪 Post-Deploy Verification (push) Successful in 1m14s
Build & Deploy / 🔔 Notify (push) Successful in 3s
Nightly QA / 💨 Smoke & Health (push) Successful in 1m7s
fix(pdf): fix Lexical AST text extraction to prevent [object Object] in datasheets
2026-08-19 11:07:22 +02:00

792 lines
18 KiB
Plaintext
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
---
title: NA2XS(FL)2Y
sku: NA2XS(FL)2Y-high-voltage-cables
description: >
Das NA2XS(FL)2Y Kabel ist ein leistungsstarkes Hochspannungskabel mit
Aluminiumleiter, VPE-Isolierung und einem wasserdichten PE-Mantel. Es bietet
hohe Betriebssicherheit und ist speziell für die Erdverlegung und anspruchsvolle
Trassenführungen konzipiert.
categories:
- Hochspannungskabel
images:
- /uploads/2025/06/NA2XSFL2Y-3-scaled.webp
application: >
Das NA2XS(FL)2Y erfüllt die Anforderungen der IEC 60840 und eignet sich für die
Verlegung im Erdreich, in Kabelkanälen, in Innenräumen, in Rohren und im Freien. Es
wird projektbezogen gefertigt und kommt insbesondere in Übertragungsnetzen,
Versorgungs-Infrastrukturen und Umspannwerken zum Einsatz, wo Sicherheit und
Langlebigkeit an erster Stelle stehen.
locale: de
---
<ProductTabs technicalData={<ProductTechnicalData data={{
"technicalItems": [
{
"label": "CPR class",
"value": "Fca",
"unit": ""
},
{
"label": "Flame retardant",
"value": "no",
"unit": ""
},
{
"label": "Maximal operating conductor temperature (°C)",
"value": "+90",
"unit": "°C"
},
{
"label": "Maximal short-circuit temperature (°C)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimal storage temperature (°C)",
"value": "-35",
"unit": "°C"
},
{
"label": "Minimal temperature for laying (°C)",
"value": "-20",
"unit": "°C"
},
{
"label": "Operating temperature range (°C)",
"value": "-35-+90",
"unit": "°C"
},
{
"label": "Shape of conductor",
"value": "RM",
"unit": ""
}
],
"voltageTables": [
{
"voltageLabel": "6/10 kV",
"metaItems": [
{
"label": "Spannung",
"value": "6/10 kV"
},
{
"label": "Prüfspannung",
"value": "21",
"unit": "kV"
},
{
"label": "Temperaturbereich",
"value": "-35-+90",
"unit": "°C"
},
{
"label": "Leitertemperatur (max.)",
"value": "+90",
"unit": "°C"
},
{
"label": "Kurzschlusstemperatur (max.)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimale Verlegetemperatur",
"value": "-20",
"unit": "°C"
},
{
"label": "Minimale Lagertemperatur",
"value": "-35",
"unit": "°C"
},
{
"label": "CPR-Klasse",
"value": "Fca",
"unit": ""
},
{
"label": "Flammhemmend",
"value": "no",
"unit": ""
}
],
"columns": [
{
"key": "Cond",
"label": "Leiter"
},
{
"key": "shape",
"label": "Form"
},
{
"key": "cap",
"label": "Cap [uF/km]"
},
{
"key": "DI",
"label": "DI [mm]"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Wi",
"label": "Wi [mm]"
},
{
"key": "Ibl",
"label": "Ibl [A]"
},
{
"key": "Ibe",
"label": "Ibe [A]"
},
{
"key": "Ik_cond",
"label": "Ik [kA]"
},
{
"key": "Wm",
"label": "Wm [mm]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x35/16",
"cells": [
"Al",
"RM",
"0.22",
"15.3",
"0.868",
"3.4",
"160",
"145",
"3.3",
"2.1",
"500",
"25",
"643"
]
},
{
"configuration": "1x50/16",
"cells": [
"Al",
"RM",
"0.25",
"16.4",
"0.641",
"3.4",
"183",
"171",
"4.7",
"2.1",
"520",
"26",
"712"
]
},
{
"configuration": "1x70/16",
"cells": [
"Al",
"RM",
"0.28",
"17.9",
"0.443",
"3.4",
"228",
"208",
"6.6",
"2.1",
"405",
"27",
"796"
]
},
{
"configuration": "1x95/16",
"cells": [
"Al",
"RM",
"0.31",
"19.4",
"0.32",
"3.4",
"280",
"251",
"9",
"2.1",
"580",
"29",
"1101"
]
},
{
"configuration": "1x120/16",
"cells": [
"Al",
"RM",
"0.23",
"25.1",
"0.253",
"3.4",
"323",
"285",
"11.3",
"2.1",
"700",
"35",
"1217"
]
},
{
"configuration": "1x150/25",
"cells": [
"Al",
"RM",
"0.25",
"26.5",
"0.206",
"3.4",
"366",
"319",
"14.2",
"2.1",
"720",
"36",
"1412"
]
},
{
"configuration": "1x185/25",
"cells": [
"Al",
"RM",
"0.27",
"28.1",
"0.164",
"3.4",
"420",
"361",
"17.5",
"2.1",
"760",
"38",
"1568"
]
},
{
"configuration": "1x240/25",
"cells": [
"Al",
"RM",
"0.3",
"30.4",
"0.125",
"3.4",
"496",
"417",
"22.7",
"2.1",
"800",
"40",
"1792"
]
},
{
"configuration": "1x300/25",
"cells": [
"Al",
"RM",
"0.32",
"32.5",
"0.1",
"3.4",
"569",
"471",
"28.4",
"2.1",
"840",
"42",
"2020"
]
},
{
"configuration": "1x400/35",
"cells": [
"Al",
"RM",
"0.36",
"35.6",
"0.078",
"3.4",
"660",
"535",
"37.8",
"2.1",
"900",
"45",
"2493"
]
},
{
"configuration": "1x500/35",
"cells": [
"Al",
"RM",
"0.4",
"38.8",
"0.061",
"3.4",
"766",
"609",
"47.3",
"2.1",
"980",
"49",
"2903"
]
},
{
"configuration": "1x500/50",
"cells": [
"Al",
"RM",
"0.4",
"38.8",
"0.061",
"3.4",
"766",
"609",
"47.3",
"2.1",
"980",
"49",
"3059"
]
},
{
"configuration": "1x630/35",
"cells": [
"Al",
"RM",
"0.44",
"42.2",
"0.047",
"3.4",
"866",
"705",
"59.6",
"2.4",
"780",
"52",
"3383"
]
},
{
"configuration": "1x800/35",
"cells": [
"Al",
"RM",
"0.49",
"46.5",
"0.037",
"3.4",
"984",
"767",
"75.6",
"2.4",
"840",
"56",
"3858"
]
},
{
"configuration": "1x1000/35",
"cells": [
"Al",
"RM",
"0.55",
"50.4",
"0.0291",
"3.4",
"1187",
"863",
"94",
"2.4",
"1220",
"61",
"4824"
]
}
]
},
{
"voltageLabel": "18/30 kV",
"metaItems": [
{
"label": "Spannung",
"value": "18/30 kV"
},
{
"label": "Prüfspannung",
"value": "63",
"unit": "kV"
},
{
"label": "Temperaturbereich",
"value": "-35-+90",
"unit": "°C"
},
{
"label": "Leitertemperatur (max.)",
"value": "+90",
"unit": "°C"
},
{
"label": "Kurzschlusstemperatur (max.)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimale Verlegetemperatur",
"value": "-20",
"unit": "°C"
},
{
"label": "Minimale Lagertemperatur",
"value": "-35",
"unit": "°C"
},
{
"label": "CPR-Klasse",
"value": "Fca",
"unit": ""
},
{
"label": "Flammhemmend",
"value": "no",
"unit": ""
}
],
"columns": [
{
"key": "Cond",
"label": "Leiter"
},
{
"key": "shape",
"label": "Form"
},
{
"key": "cap",
"label": "Cap [uF/km]"
},
{
"key": "DI",
"label": "DI [mm]"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Wi",
"label": "Wi [mm]"
},
{
"key": "Ibl",
"label": "Ibl [A]"
},
{
"key": "Ibe",
"label": "Ibe [A]"
},
{
"key": "Ik_cond",
"label": "Ik [kA]"
},
{
"key": "Wm",
"label": "Wm [mm]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x50/16",
"cells": [
"Al",
"RM",
"0.13",
"25.6",
"0.641",
"8",
"187",
"174",
"4.7",
"2.1",
"700",
"35",
"1100"
]
},
{
"configuration": "1x70/16",
"cells": [
"Al",
"RM",
"0.15",
"27.1",
"0.443",
"8",
"232",
"213",
"6.6",
"2.1",
"740",
"37",
"1213"
]
},
{
"configuration": "1x95/16",
"cells": [
"Al",
"RM",
"0.16",
"28.6",
"0.32",
"8",
"282",
"254",
"9",
"2.1",
"760",
"38",
"1339"
]
},
{
"configuration": "1x120/16",
"cells": [
"Al",
"RM",
"0.17",
"30.1",
"0.253",
"8",
"325",
"289",
"11.3",
"2.1",
"800",
"40",
"1463"
]
},
{
"configuration": "1x150/25",
"cells": [
"Al",
"RM",
"0.19",
"31.5",
"0.206",
"8",
"367",
"322",
"14.2",
"2.1",
"820",
"41",
"1660"
]
},
{
"configuration": "1x185/25",
"cells": [
"Al",
"RM",
"0.2",
"33.1",
"0.164",
"8",
"421",
"364",
"17.5",
"2.1",
"860",
"43",
"1837"
]
},
{
"configuration": "1x240/25",
"cells": [
"Al",
"RM",
"0.22",
"35.4",
"0.125",
"8",
"496",
"422",
"22.7",
"2.1",
"900",
"45",
"2049"
]
},
{
"configuration": "1x300/25",
"cells": [
"Al",
"RM",
"0.24",
"37.5",
"0.1",
"8",
"568",
"476",
"28.4",
"2.1",
"940",
"47",
"2336"
]
},
{
"configuration": "1x400/35",
"cells": [
"Al",
"RM",
"0.27",
"40.6",
"0.0778",
"8",
"659",
"541",
"37.8",
"2.1",
"1000",
"50",
"2842"
]
},
{
"configuration": "1x500/35",
"cells": [
"Al",
"RM",
"0.29",
"43.8",
"0.0605",
"8",
"764",
"616",
"47.3",
"2.4",
"1080",
"54",
"3269"
]
},
{
"configuration": "1x630/35",
"cells": [
"Al",
"RM",
"0.32",
"47.2",
"0.0469",
"8",
"866",
"692",
"59.6",
"2.4",
"1120",
"56",
"3590"
]
},
{
"configuration": "1x800/35",
"cells": [
"Al",
"RM",
"0.36",
"51.5",
"0.0367",
"8",
"984",
"770",
"75.6",
"2.4",
"1200",
"60",
"4284"
]
},
{
"configuration": "1x1000/35",
"cells": [
"Al",
"RM",
"0.39",
"55.4",
"0.0291",
"8",
"1196",
"878",
"94",
"2.4",
"1340",
"67",
"5327"
]
}
]
}
]
}} />}>
<section>
<h3 data-start="443" data-end="505">Ideal für Hochspannungsanwendungen im Erdreich und im Freien</h3>
<p data-start="507" data-end="867">Das <strong data-start="511" data-end="526">NA2XS(FL)2Y</strong> erfüllt die Anforderungen der <strong data-start="557" data-end="570">IEC 60840</strong> und eignet sich für die <strong data-start="595" data-end="669">Verlegung im Erdreich, in Kabelkanälen, in Innenräumen, in Rohren und im Freien</strong>. Es wird projektbezogen gefertigt und kommt insbesondere in <strong data-start="725" data-end="798">Übertragungsnetzen, Versorgungs-Infrastrukturen und Umspannwerken</strong> zum Einsatz, wo Sicherheit und Langlebigkeit an erster Stelle stehen.</p>
<h3 data-start="869" data-end="904">Aufbau und technische Merkmale</h3>
<p data-start="906" data-end="1465">Im Kern verfügt das Kabel über einen <strong data-start="927" data-end="975">verdichteten, mehrdrähtigen Aluminiumleiter</strong> nach <strong data-start="981" data-end="994">IEC 60228</strong>, eingebettet in eine <strong data-start="1016" data-end="1043">leitfähige Innenschicht</strong>, eine <strong data-start="1050" data-end="1068">VPE-Isolierung</strong> und eine <strong data-start="1078" data-end="1128">fest verbundene, extrudierte Außenschicht</strong>. Die Kombination aus <strong data-start="1150" data-end="1177">quellfähigem Band</strong>, <strong data-start="1179" data-end="1219">Kupferschirmung mit offener Wendel</strong> und einer zusätzlichen <strong data-start="1239" data-end="1263">quellfähigen Bewicklung</strong> schützt das Kabel effektiv vor Feuchtigkeitseintritt. Der schwarze <strong data-start="1336" data-end="1396">PE-Mantel mit fest verschweißter Aluminiumbandierung (Alucopo)</strong> dient sowohl als mechanischer Schutz als auch als <strong data-start="1444" data-end="1464">Querwassersperre</strong>.</p>
<h3 data-start="1467" data-end="1505">Eigenschaften und Anwendungsvorteile</h3>
<p data-start="1507" data-end="1827">Das NA2XS(FL)2Y ist <strong data-start="1527" data-end="1543">für die direkte Erdverlegung geeignet</strong>, <strong data-start="1545" data-end="1569">mechanisch robust</strong> und bietet durch seinen <strong data-start="1594" data-end="1625">teilentladungsfreien Aufbau</strong> sowie die wasserabweisende Konstruktion eine exzellente Betriebssicherheit. Es wird projektspezifisch konfiguriert und lässt sich flexibel einsetzen von städtischen Energieprojekten bis hin zu großen Industrieanlagen.</p>
</section>
</ProductTabs>