title: NY2Y
sku: NY2Y-low-voltage-cables
description: >
Das NY2Y ist ein besonders widerstandsfähiges Niederspannungskabel für die
feste Verlegung unter hohen mechanischen Anforderungen ob im Erdreich, im
Wasser oder in industrieller Umgebung. Dank seiner Materialkombination ist es
für vielfältige Einsatzbedingungen bestens geeignet.
categories:
- Niederspannungskabel
images:
- /uploads/2025/01/NY2Y-scaled.webp
locale: de
---
<ProductTabs technicalData={<ProductTechnicalData data={{
"technicalItems": [
{
"label": "Biegeradius (mm)",
"value": "15/12xD",
"unit": "mm"
},
{
"label": "CPR class",
"value": "Fca",
"unit": ""
},
{
"label": "Maximal operating conductor temperature (°C)",
"value": "70",
"unit": "°C"
},
{
"label": "Maximal short-circuit temperature (°C)",
"value": "300 mm2: +140",
"unit": "°C"
},
{
"label": "Minimal storage temperature (°C)",
"value": "-35",
"unit": "°C"
},
{
"label": "Minimal temperature for laying (°C)",
"value": "-5",
"unit": "°C"
},
{
"label": "Nennspannung (kV)",
"value": "0.6/1",
"unit": "kV"
},
{
"label": "Prüfspannung (kV)",
"value": "4",
"unit": "kV"
},
{
"label": "Self-extinguishing of single cable",
"value": "no",
"unit": ""
},
{
"label": "Temperaturbereich (°C)",
"value": "-35-+70",
"unit": "°C"
}
],
"voltageTables": [
{
"voltageLabel": "0.6/1 kV",
"metaItems": [
{
"label": "Spannung",
"value": "0.6/1 kV"
},
{
"label": "Prüfspannung",
"value": "4",
"unit": "kV"
},
{
"label": "Temperaturbereich",
"value": "-35-+70",
"unit": "°C"
},
{
"label": "Leitertemperatur (max.)",
"value": "70",
"unit": "°C"
},
{
"label": "Kurzschlusstemperatur (max.)",
"value": "300 mm2: +140",
"unit": "°C"
},
{
"label": "Minimale Verlegetemperatur",
"value": "-5",
"unit": "°C"
},
{
"label": "Minimale Lagertemperatur",
"value": "-35",
"unit": "°C"
},
{
"label": "CPR-Klasse",
"value": "Fca",
"unit": ""
},
{
"label": "Flammhemmend",
"value": "no",
"unit": ""
}
],
"columns": [
{
"key": "Cond",
"label": "Leiter"
},
{
"key": "shape",
"label": "Form"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Wi",
"label": "Wi [mm]"
},
{
"key": "Wm",
"label": "Wm [mm]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x10",
"cells": [
"Cu",
"RE",
"1,83",
"1",
"1,8",
"12xD",
"10",
"157"
]
},
{
"configuration": "1x16",
"cells": [
"Cu",
"RE",
"1,15",
"1",
"1,8",
"12xD",
"11",
"219"
]
},
{
"configuration": "1x25",
"cells": [
"Cu",
"RMV",
"0,727",
"1,2",
"1,8",
"12xD",
"12",
"329"
]
},
{
"configuration": "1x35",
"cells": [
"Cu",
"RMV",
"0,524",
"1,2",
"1,8",
"12xD",
"14",
"429"
]
},
{
"configuration": "1x50",
"cells": [
"Cu",
"RMV",
"0,387",
"1,4",
"1,8",
"12xD",
"15",
"565"
]
},
{
"configuration": "1x70",
"cells": [
"Cu",
"RMV",
"0,268",
"1,4",
"1,8",
"12xD",
"17",
"772"
]
},
{
"configuration": "1x95",
"cells": [
"Cu",
"RMV",
"0,193",
"1,6",
"1,8",
"12xD",
"19",
"1042"
]
},
{
"configuration": "1x120",
"cells": [
"Cu",
"RMV",
"0,153",
"1,6",
"1,8",
"12xD",
"20",
"1278"
]
},
{
"configuration": "1x150",
"cells": [
"Cu",
"RMV",
"0,124",
"1,8",
"1,8",
"12xD",
"22",
"1571"
]
},
{
"configuration": "1x185",
"cells": [
"Cu",
"RMV",
"0,0991",
"2",
"1,8",
"12xD",
"25",
"1947"
]
},
{
"configuration": "1x240",
"cells": [
"Cu",
"RMV",
"0,0754",
"2,2",
"1,8",
"12xD",
"27",
"2514"
]
},
{
"configuration": "1x300",
"cells": [
"Cu",
"RMV",
"0,0601",
"2,4",
"1,9",
"12xD",
"30",
"3130"
]
},
{
"configuration": "1x400",
"cells": [
"Cu",
"RMV",
"0,047",
"2,6",
"2",
"12xD",
"34",
"3972"
]
},
{
"configuration": "1x500",
"cells": [
"Cu",
"RMV",
"0,0366",
"2,8",
"2,1",
"12xD",
"37",
"5043"
]
},
{
"configuration": "3x10",
"cells": [
"Cu",
"RE",
"1,83",
"1",
"1,8",
"12xD",
"18",
"589"
]
},
{
"configuration": "3x16",
"cells": [
"Cu",
"RE",
"1,15",
"1",
"1,8",
"12xD",
"20",
"810"
]
},
{
"configuration": "3x25",
"cells": [
"Cu",
"RMV",
"0,727",
"1,2",
"1,8",
"12xD",
"24",
"1227"
]
},
{
"configuration": "3x35",
"cells": [
"Cu",
"SM",
"0,524",
"1,2",
"1,8",
"12xD",
"25",
"1464"
]
},
{
"configuration": "3x50",
"cells": [
"Cu",
"SM",
"0,387",
"1,4",
"1,8",
"12xD",
"28",
"1887"
]
},
{
"configuration": "3x70",
"cells": [
"Cu",
"SM",
"0,268",
"1,4",
"2",
"12xD",
"31",
"2584"
]
},
{
"configuration": "3x95",
"cells": [
"Cu",
"SM",
"0,193",
"1,6",
"2,1",
"12xD",
"36",
"3448"
]
},
{
"configuration": "3x120",
"cells": [
"Cu",
"SM",
"0,153",
"1,6",
"2,2",
"12xD",
"38",
"4199"
]
},
{
"configuration": "3x150",
"cells": [
"Cu",
"SM",
"0,124",
"1,8",
"2,3",
"12xD",
"43",
"5178"
]
},
{
"configuration": "3x185",
"cells": [
"Cu",
"SM",
"0,0991",
"2",
"2,5",
"12xD",
"47",
"6381"
]
},
{
"configuration": "3x240",
"cells": [
"Cu",
"SM",
"0,0754",
"2,2",
"2,7",
"12xD",
"53",
"8264"
]
},
{
"configuration": "3x35+16",
"cells": [
"Cu",
"SM/RE",
"0,524",
"1.2/1.0",
"1,8",
"12xD",
"27",
"1698"
]
}
]
}
]
}} />}>
<section>
<h3 data-start="518" data-end="554">Zuverlässig bei hoher Belastung</h3>
<p data-start="556" data-end="987">Das <strong data-start="560" data-end="568">NY2Y</strong> ist ein Niederspannungskabel für den Einsatz in Kraftwerken, Industrie- und Schaltanlagen sowie in Ortsnetzen. Es eignet sich für die <strong data-start="706" data-end="792">feste Verlegung in Innenräumen, Kabelkanälen, im Freien, im Wasser und im Erdreich</strong> überall dort, wo starke mechanische Belastungen beim Verlegen und im Betrieb zu erwarten sind. Die Konstruktion erfüllt die Vorgaben gemäß <strong data-start="934" data-end="953">TP PRAKAB 16/03</strong> in Anlehnung an <strong data-start="970" data-end="986">VDE 0276-603</strong>.</p>
<h3 data-start="989" data-end="1010">Aufbau im Detail</h3>
<p data-start="1012" data-end="1431">Das Kabel besteht aus einem <strong data-start="1040" data-end="1056">Kupferleiter</strong>, verfügbar als rund eindrähtig (RE), rund mehrdrähtig (RM) oder sektorförmig mehrdrähtig (SM). Die <strong data-start="1156" data-end="1177">PVC-Aderisolation</strong> sorgt für elektrische Sicherheit, die Adern sind verseilt und durch eine gemeinsame <strong data-start="1262" data-end="1284">EPDM-Aderumhüllung</strong> geschützt. Der Außenmantel aus <strong data-start="1316" data-end="1324">HDPE</strong> (schwarz, UV-beständig) macht das NY2Y besonders resistent gegen Abrieb, Feuchtigkeit und Umwelteinflüsse.</p>
<h3 data-start="1433" data-end="1462">Typische Einsatzbereiche</h3>
<p data-start="1464" data-end="1802">NY2Y eignet sich hervorragend für Anwendungen mit erhöhten Anforderungen an <strong data-start="1540" data-end="1566">mechanische Robustheit</strong> und <strong data-start="1571" data-end="1598">Witterungsbeständigkeit</strong>. Typische Einsatzorte sind Energieverteilungen in industriellen Anlagen, Kraftwerken oder Trafostationen aber auch in Umgebungen mit Feuchtigkeit, direkter Sonneneinstrahlung oder chemischer Belastung.</p>
</section>
</ProductTabs>