title: NY2Y
sku: NY2Y-low-voltage-cables
description: >
The NY2Y is an especially robust low-voltage cable for fixed installation
under high mechanical demands whether underground, in water, or in
industrial environments. Thanks to its material combination, it is perfectly
suited for a wide range of application conditions.
categories:
- Low Voltage Cables
images:
- /uploads/2025/01/NY2Y-scaled.webp
application: >
The NY2Y is a low-voltage cable for use in power plants, industrial facilities,
switching stations, and local distribution networks. It is suitable for fixed
installation indoors, in cable ducts, outdoors, in water, and underground wherever
strong mechanical stress is expected during installation and operation. The
construction complies with TP PRAKAB 16/03 based on VDE 0276-603.
locale: en
---
<ProductTabs technicalData={<ProductTechnicalData data={{
"technicalItems": [
{
"label": "Bending radius (mm)",
"value": "15/12xD",
"unit": "mm"
},
{
"label": "CPR class",
"value": "Fca",
"unit": ""
},
{
"label": "Maximal operating conductor temperature (°C)",
"value": "70",
"unit": "°C"
},
{
"label": "Maximal short-circuit temperature (°C)",
"value": "300 mm2: +140",
"unit": "°C"
},
{
"label": "Minimal storage temperature (°C)",
"value": "-35",
"unit": "°C"
},
{
"label": "Minimal temperature for laying (°C)",
"value": "-5",
"unit": "°C"
},
{
"label": "Operating temperature range (°C)",
"value": "-35-+70",
"unit": "°C"
},
{
"label": "Rated voltage (kV)",
"value": "0.6/1",
"unit": "kV"
},
{
"label": "Self-extinguishing of single cable",
"value": "no",
"unit": ""
},
{
"label": "Test voltage (kV)",
"value": "4",
"unit": "kV"
}
],
"voltageTables": [
{
"voltageLabel": "0.6/1 kV",
"metaItems": [
{
"label": "Voltage",
"value": "0.6/1 kV"
},
{
"label": "Test voltage",
"value": "4",
"unit": "kV"
},
{
"label": "Operating temperature range",
"value": "-35-+70",
"unit": "°C"
},
{
"label": "Conductor temperature (max.)",
"value": "70",
"unit": "°C"
},
{
"label": "Short-circuit temperature (max.)",
"value": "300 mm2: +140",
"unit": "°C"
},
{
"label": "Minimum laying temperature",
"value": "-5",
"unit": "°C"
},
{
"label": "Minimum storage temperature",
"value": "-35",
"unit": "°C"
},
{
"label": "CPR class",
"value": "Fca",
"unit": ""
},
{
"label": "Flame retardant",
"value": "no",
"unit": ""
}
],
"columns": [
{
"key": "Cond",
"label": "Cond."
},
{
"key": "shape",
"label": "Shape"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Wi",
"label": "Wi [mm]"
},
{
"key": "Wm",
"label": "Wm [mm]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x10",
"cells": [
"Cu",
"RE",
"1.83",
"1",
"1.8",
"12xD",
"10",
"157"
]
},
{
"configuration": "1x16",
"cells": [
"Cu",
"RE",
"1.15",
"1",
"1.8",
"12xD",
"11",
"219"
]
},
{
"configuration": "1x25",
"cells": [
"Cu",
"RMV",
"0.727",
"1.2",
"1.8",
"12xD",
"12",
"329"
]
},
{
"configuration": "1x35",
"cells": [
"Cu",
"RMV",
"0.524",
"1.2",
"1.8",
"12xD",
"14",
"429"
]
},
{
"configuration": "1x50",
"cells": [
"Cu",
"RMV",
"0.387",
"1.4",
"1.8",
"12xD",
"15",
"565"
]
},
{
"configuration": "1x70",
"cells": [
"Cu",
"RMV",
"0.268",
"1.4",
"1.8",
"12xD",
"17",
"772"
]
},
{
"configuration": "1x95",
"cells": [
"Cu",
"RMV",
"0.193",
"1.6",
"1.8",
"12xD",
"19",
"1042"
]
},
{
"configuration": "1x120",
"cells": [
"Cu",
"RMV",
"0.153",
"1.6",
"1.8",
"12xD",
"20",
"1278"
]
},
{
"configuration": "1x150",
"cells": [
"Cu",
"RMV",
"0.124",
"1.8",
"1.8",
"12xD",
"22",
"1571"
]
},
{
"configuration": "1x185",
"cells": [
"Cu",
"RMV",
"0.0991",
"2",
"1.8",
"12xD",
"25",
"1947"
]
},
{
"configuration": "1x240",
"cells": [
"Cu",
"RMV",
"0.0754",
"2.2",
"1.8",
"12xD",
"27",
"2514"
]
},
{
"configuration": "1x300",
"cells": [
"Cu",
"RMV",
"0.0601",
"2.4",
"1.9",
"12xD",
"30",
"3130"
]
},
{
"configuration": "1x400",
"cells": [
"Cu",
"RMV",
"0.047",
"2.6",
"2",
"12xD",
"34",
"3972"
]
},
{
"configuration": "1x500",
"cells": [
"Cu",
"RMV",
"0.0366",
"2.8",
"2.1",
"12xD",
"37",
"5043"
]
},
{
"configuration": "3x10",
"cells": [
"Cu",
"RE",
"1.83",
"1",
"1.8",
"12xD",
"18",
"589"
]
},
{
"configuration": "3x16",
"cells": [
"Cu",
"RE",
"1.15",
"1",
"1.8",
"12xD",
"20",
"810"
]
},
{
"configuration": "3x25",
"cells": [
"Cu",
"RMV",
"0.727",
"1.2",
"1.8",
"12xD",
"24",
"1227"
]
},
{
"configuration": "3x35",
"cells": [
"Cu",
"SM",
"0.524",
"1.2",
"1.8",
"12xD",
"25",
"1464"
]
},
{
"configuration": "3x50",
"cells": [
"Cu",
"SM",
"0.387",
"1.4",
"1.8",
"12xD",
"28",
"1887"
]
},
{
"configuration": "3x70",
"cells": [
"Cu",
"SM",
"0.268",
"1.4",
"2",
"12xD",
"31",
"2584"
]
},
{
"configuration": "3x95",
"cells": [
"Cu",
"SM",
"0.193",
"1.6",
"2.1",
"12xD",
"36",
"3448"
]
},
{
"configuration": "3x120",
"cells": [
"Cu",
"SM",
"0.153",
"1.6",
"2.2",
"12xD",
"38",
"4199"
]
},
{
"configuration": "3x150",
"cells": [
"Cu",
"SM",
"0.124",
"1.8",
"2.3",
"12xD",
"43",
"5178"
]
},
{
"configuration": "3x185",
"cells": [
"Cu",
"SM",
"0.0991",
"2",
"2.5",
"12xD",
"47",
"6381"
]
},
{
"configuration": "3x240",
"cells": [
"Cu",
"SM",
"0.0754",
"2.2",
"2.7",
"12xD",
"53",
"8264"
]
},
{
"configuration": "3x35+16",
"cells": [
"Cu",
"SM/RE",
"0.524",
"1.2/1.0",
"1.8",
"12xD",
"27",
"1698"
]
}
]
}
]
}} />}>
<section>
<h3 data-start="518" data-end="554">Reliable under heavy load</h3>
<p data-start="556" data-end="987">The <strong data-start="560" data-end="568">NY2Y</strong> is a low-voltage cable for use in power plants, industrial facilities, switching stations, and local distribution networks. It is suitable for <strong data-start="706" data-end="792">fixed installation indoors, in cable ducts, outdoors, in water, and underground</strong> wherever strong mechanical stress is expected during installation and operation. The construction complies with <strong data-start="934" data-end="953">TP PRAKAB 16/03</strong> based on <strong data-start="970" data-end="986">VDE 0276-603</strong>.</p>
<h3 data-start="989" data-end="1010">Detailed construction</h3>
<p data-start="1012" data-end="1431">The cable consists of a <strong data-start="1040" data-end="1056">copper conductor</strong>, available as solid round (RE), stranded round (RM), or sector-shaped stranded (SM). The <strong data-start="1156" data-end="1177">PVC core insulation</strong> ensures electrical safety, while the cores are stranded together and protected by a common <strong data-start="1262" data-end="1284">EPDM sheath</strong>. The outer sheath made of <strong data-start="1316" data-end="1324">HDPE</strong> (black, UV-resistant) makes the NY2Y particularly resistant to abrasion, moisture, and environmental influences.</p>
<h3 data-start="1433" data-end="1462">Typical applications</h3>
<p data-start="1464" data-end="1802">NY2Y is ideally suited for applications with increased requirements for <strong data-start="1540" data-end="1566">mechanical strength</strong> and <strong data-start="1571" data-end="1598">weather resistance</strong>. Typical fields of use include power distribution in industrial plants, power stations, or transformer stations but also in environments with moisture, direct sunlight, or chemical exposure.</p>
</section>
</ProductTabs>