title: N2XS(F)2Y
sku: N2XS(F)2Y-medium-voltage-cables
description: >
The N2XS(F)2Y cable is a longitudinally watertight medium-voltage cable with a
copper conductor, XLPE insulation, and a durable PE sheath. It combines high
electrical safety with a rugged outer layer, making it ideal for demanding
grid operation applications.
categories:
- Medium Voltage Cables
images:
- /uploads/2025/01/N2XSF2Y-3-scaled.webp
application: >
The N2XSF2Y complies with common standards DIN VDE 0276-620, HD 620 S2 and IEC 60502,
and is suitable for installation indoors, in cable ducts, outdoors, in water,
underground, and on cable trays. This cable proves its strengths especially in
utility grids, industrial plants, and power stations wherever durability,
watertightness, and safety are essential.
locale: en
---
<ProductTabs technicalData={<ProductTechnicalData data={{
"technicalItems": [
{
"label": "CPR class",
"value": "Fca",
"unit": ""
},
{
"label": "Flame retardant",
"value": "no",
"unit": ""
},
{
"label": "Maximal operating conductor temperature (°C)",
"value": "+90",
"unit": "°C"
},
{
"label": "Maximal short-circuit temperature (°C)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimal storage temperature (°C)",
"value": "-35",
"unit": "°C"
},
{
"label": "Minimal temperature for laying (°C)",
"value": "-20",
"unit": "°C"
},
{
"label": "Minimum sheath thickness (mm)",
"value": "2.1",
"unit": "mm"
},
{
"label": "Nominal insulation thickness (mm)",
"value": "5.5",
"unit": "mm"
},
{
"label": "Operating temperature range (°C)",
"value": "-35-+90",
"unit": "°C"
},
{
"label": "Rated voltage (kV)",
"value": "12/20",
"unit": "kV"
},
{
"label": "Shape of conductor",
"value": "RM",
"unit": ""
},
{
"label": "Test voltage (kV)",
"value": "42",
"unit": "kV"
}
],
"voltageTables": [
{
"voltageLabel": "12/20 kV",
"metaItems": [
{
"label": "Voltage",
"value": "12/20 kV"
},
{
"label": "Test voltage",
"value": "42",
"unit": "kV"
},
{
"label": "Operating temperature range",
"value": "-35-+90",
"unit": "°C"
},
{
"label": "Conductor temperature (max.)",
"value": "+90",
"unit": "°C"
},
{
"label": "Short-circuit temperature (max.)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimum laying temperature",
"value": "-20",
"unit": "°C"
},
{
"label": "Minimum storage temperature",
"value": "-35",
"unit": "°C"
},
{
"label": "CPR class",
"value": "Fca",
"unit": ""
},
{
"label": "Flame retardant",
"value": "no",
"unit": ""
}
],
"columns": [
{
"key": "Cond",
"label": "Cond."
},
{
"key": "shape",
"label": "Shape"
},
{
"key": "cap",
"label": "Cap [uF/km]"
},
{
"key": "DI",
"label": "DI [mm]"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Wi",
"label": "Wi [mm]"
},
{
"key": "Ibl",
"label": "Ibl [A]"
},
{
"key": "Ibe",
"label": "Ibe [A]"
},
{
"key": "Ik_cond",
"label": "Ik [kA]"
},
{
"key": "Wm",
"label": "Wm [mm]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x35/16",
"cells": [
"Cu",
"RM",
"0.16",
"19.5",
"0.524",
"5.5",
"200",
"189",
"5",
"2.1",
"420",
"28",
"949"
]
},
{
"configuration": "1x50/16",
"cells": [
"Cu",
"RM",
"0.17",
"20.5",
"0.387",
"5.5",
"239",
"222",
"7.1",
"2.1",
"435",
"29",
"1079"
]
},
{
"configuration": "1x70/16",
"cells": [
"Cu",
"RM",
"0.19",
"22.1",
"0.268",
"5.5",
"297",
"271",
"10",
"2.1",
"465",
"31",
"1315"
]
},
{
"configuration": "1x95/16",
"cells": [
"Cu",
"RM",
"0.21",
"23.6",
"0.193",
"5.5",
"361",
"323",
"13.6",
"2.1",
"480",
"32",
"1580"
]
},
{
"configuration": "1x120/16",
"cells": [
"Cu",
"RM",
"0.23",
"25.1",
"0.153",
"5.5",
"416",
"367",
"17.1",
"2.1",
"510",
"34",
"1862"
]
},
{
"configuration": "1x150/25",
"cells": [
"Cu",
"RM",
"0.25",
"26.5",
"0.124",
"5.5",
"470",
"409",
"21.4",
"2.1",
"525",
"35",
"2212"
]
},
{
"configuration": "1x185/25",
"cells": [
"Cu",
"RM",
"0.27",
"28.1",
"0.099",
"5.5",
"538",
"461",
"26.4",
"2.1",
"555",
"37",
"2585"
]
},
{
"configuration": "1x240/25",
"cells": [
"Cu",
"RM",
"0.3",
"30.6",
"0.075",
"5.5",
"634",
"532",
"34.3",
"2.1",
"585",
"39",
"3181"
]
},
{
"configuration": "1x300/25",
"cells": [
"Cu",
"RM",
"0.33",
"33",
"0.06",
"5.5",
"724",
"599",
"42.9",
"2.1",
"630",
"42",
"3851"
]
},
{
"configuration": "1x400/35",
"cells": [
"Cu",
"RM",
"0.36",
"35.6",
"0.047",
"5.5",
"829",
"671",
"57.2",
"2.1",
"660",
"44",
"4795"
]
},
{
"configuration": "1x500/35",
"cells": [
"Cu",
"RM",
"0.4",
"38.8",
"0.037",
"5.5",
"953",
"754",
"71.4",
"2.1",
"705",
"47",
"5873"
]
}
]
}
]
}} />}>
<section>
<h3 data-start="452" data-end="502">Designed for high-performance network environments</h3>
<p data-start="504" data-end="904">The <strong data-start="508" data-end="521">N2XS(F)2Y</strong> complies with common standards <strong data-start="550" data-end="570">DIN VDE 0276-620</strong>, <strong data-start="572" data-end="585">HD 620 S2</strong> and <strong data-start="590" data-end="603">IEC 60502</strong>, and is suitable for <strong data-start="620" data-end="713">installation indoors, in cable ducts, outdoors, in water, underground, and on cable trays</strong>. This cable proves its strengths especially in <strong data-start="737" data-end="785">utility grids, industrial plants, and power stations</strong> wherever durability, watertightness, and safety are essential.</p>
<h3 data-start="906" data-end="946">Structure and technical characteristics</h3>
<p data-start="948" data-end="1387">Inside is a <strong data-start="977" data-end="1016">bare, multi-stranded copper conductor</strong> (Class 2), surrounded by an <strong data-start="1047" data-end="1123">extruded XLPE insulation with inner and bonded outer conductive layer</strong>. A <strong data-start="1130" data-end="1174">longitudinally watertight, conductive tape</strong>, a <strong data-start="1181" data-end="1234">copper wire screen with counter helix</strong>, and an additional <strong data-start="1256" data-end="1282">longitudinally watertight layer</strong> ensure the design's integrity. The black <strong data-start="1316" data-end="1345">PE outer sheath (Type DMP2)</strong> provides high mechanical strength.</p>
<h3 data-start="1389" data-end="1425">Applications and benefits</h3>
<p data-start="1427" data-end="1822">The N2XS(F)2Y is <strong data-start="1445" data-end="1461">suitable for underground installation</strong>, <strong data-start="1463" data-end="1509">resistant to aggressive environmental conditions</strong>, and withstands <strong data-start="1519" data-end="1562">temperatures up to +90°C in continuous operation</strong> and <strong data-start="1569" data-end="1599">+250°C in short-circuit conditions</strong>. It is <strong data-start="1614" data-end="1663">free from silicone and cadmium-containing substances</strong> and, thanks to its <strong data-start="1677" data-end="1709">partial discharge-free design</strong>, particularly suitable for networks with the highest demands on <strong data-start="1769" data-end="1803">electrical operational safety</strong> and longevity.</p>
</section>
</ProductTabs>