Files
klz-cables.com/data/products/en/n2xs2y.mdx
2026-01-29 15:45:35 +01:00

969 lines
21 KiB
Plaintext
Raw Blame History

This file contains invisible Unicode characters
This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
---
title: N2XS2Y
sku: N2XS2Y-medium-voltage-cables
description: >
The N2XS2Y cable is a robust medium-voltage cable with a copper conductor,
XLPE insulation, and a durable PE sheath. It ensures reliable power
transmission even under high mechanical stress and demanding environmental
conditions.
categories:
- Medium Voltage Cables
images:
- /uploads/2025/01/N2XS2Y-scaled.webp
application: >
The N2XS2Y complies with the standards DIN VDE 0276-620, HD 620 S2 and IEC 60502. It is
suitable for installation indoors, in cable ducts, outdoors, in water, on cable
trays, and especially underground. Thanks to its robust sheath, it is frequently
used in industrial plants, power stations, and switching stations, where stability
and durability are essential.
locale: en
---
<ProductTabs technicalData={<ProductTechnicalData data={{
"technicalItems": [
{
"label": "CPR class",
"value": "Fca",
"unit": ""
},
{
"label": "Flame retardant",
"value": "no",
"unit": ""
},
{
"label": "Maximal operating conductor temperature (°C)",
"value": "+90",
"unit": "°C"
},
{
"label": "Maximal short-circuit temperature (°C)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimal storage temperature (°C)",
"value": "-35",
"unit": "°C"
},
{
"label": "Minimal temperature for laying (°C)",
"value": "-20",
"unit": "°C"
},
{
"label": "Operating temperature range (°C)",
"value": "-35-+90",
"unit": "°C"
},
{
"label": "Shape of conductor",
"value": "RM",
"unit": ""
}
],
"voltageTables": [
{
"voltageLabel": "6/10 kV",
"metaItems": [
{
"label": "Voltage",
"value": "6/10 kV"
},
{
"label": "Test voltage",
"value": "21",
"unit": "kV"
},
{
"label": "Operating temperature range",
"value": "-35-+90",
"unit": "°C"
},
{
"label": "Conductor temperature (max.)",
"value": "+90",
"unit": "°C"
},
{
"label": "Short-circuit temperature (max.)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimum laying temperature",
"value": "-20",
"unit": "°C"
},
{
"label": "Minimum storage temperature",
"value": "-35",
"unit": "°C"
},
{
"label": "CPR class",
"value": "Fca",
"unit": ""
},
{
"label": "Flame retardant",
"value": "no",
"unit": ""
}
],
"columns": [
{
"key": "Cond",
"label": "Cond."
},
{
"key": "shape",
"label": "Shape"
},
{
"key": "cap",
"label": "Cap [uF/km]"
},
{
"key": "DI",
"label": "DI [mm]"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Wi",
"label": "Wi [mm]"
},
{
"key": "Ibl",
"label": "Ibl [A]"
},
{
"key": "Ibe",
"label": "Ibe [A]"
},
{
"key": "Ik_cond",
"label": "Ik [kA]"
},
{
"key": "Wm",
"label": "Wm [mm]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x35/16",
"cells": [
"Cu",
"RM",
"0.22",
"15.3",
"0.524",
"3.4",
"197",
"187",
"5",
"2.1",
"360",
"24",
"803"
]
},
{
"configuration": "1x50/16",
"cells": [
"Cu",
"RM",
"0.24",
"16.3",
"0.387",
"3.4",
"238",
"220",
"7.1",
"2.1",
"375",
"25",
"928"
]
},
{
"configuration": "1x70/16",
"cells": [
"Cu",
"RM",
"0.28",
"17.9",
"0.268",
"3.4",
"294",
"268",
"10",
"2.1",
"390",
"26",
"1154"
]
},
{
"configuration": "1x95/16",
"cells": [
"Cu",
"RM",
"0.3",
"19.4",
"0.193",
"3.4",
"358",
"320",
"13.6",
"2.1",
"420",
"28",
"1410"
]
},
{
"configuration": "1x120/16",
"cells": [
"Cu",
"RM",
"0.34",
"20.9",
"0.153",
"3.4",
"413",
"363",
"17.1",
"2.1",
"450",
"30",
"1682"
]
},
{
"configuration": "1x150/25",
"cells": [
"Cu",
"RM",
"0.36",
"22.3",
"0.124",
"3.4",
"468",
"405",
"21.4",
"2.1",
"465",
"31",
"2025"
]
},
{
"configuration": "1x185/25",
"cells": [
"Cu",
"RM",
"0.4",
"23.9",
"0.099",
"3.4",
"535",
"456",
"26.4",
"2.1",
"480",
"32",
"2383"
]
},
{
"configuration": "1x240/25",
"cells": [
"Cu",
"RM",
"0.44",
"26.4",
"0.075",
"3.4",
"631",
"526",
"34.3",
"2.1",
"525",
"35",
"2965"
]
},
{
"configuration": "1x300/25",
"cells": [
"Cu",
"RM",
"0.49",
"28.8",
"0.06",
"3.4",
"722",
"591",
"42.9",
"2.1",
"555",
"37",
"3624"
]
},
{
"configuration": "1x400/35",
"cells": [
"Cu",
"RM",
"0.54",
"31.4",
"0.047",
"3.4",
"827",
"662",
"57.2",
"2.1",
"600",
"40",
"4574"
]
},
{
"configuration": "1x500/35",
"cells": [
"Cu",
"RM",
"0.61",
"34.6",
"0.037",
"3.4",
"949",
"744",
"71.4",
"2.1",
"645",
"43",
"5597"
]
}
]
},
{
"voltageLabel": "12/20 kV",
"metaItems": [
{
"label": "Voltage",
"value": "12/20 kV"
},
{
"label": "Test voltage",
"value": "42",
"unit": "kV"
},
{
"label": "Operating temperature range",
"value": "-35-+90",
"unit": "°C"
},
{
"label": "Conductor temperature (max.)",
"value": "+90",
"unit": "°C"
},
{
"label": "Short-circuit temperature (max.)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimum laying temperature",
"value": "-20",
"unit": "°C"
},
{
"label": "Minimum storage temperature",
"value": "-35",
"unit": "°C"
},
{
"label": "CPR class",
"value": "Fca",
"unit": ""
},
{
"label": "Flame retardant",
"value": "no",
"unit": ""
}
],
"columns": [
{
"key": "Cond",
"label": "Cond."
},
{
"key": "shape",
"label": "Shape"
},
{
"key": "cap",
"label": "Cap [uF/km]"
},
{
"key": "DI",
"label": "DI [mm]"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Wi",
"label": "Wi [mm]"
},
{
"key": "Ibl",
"label": "Ibl [A]"
},
{
"key": "Ibe",
"label": "Ibe [A]"
},
{
"key": "Ik_cond",
"label": "Ik [kA]"
},
{
"key": "Wm",
"label": "Wm [mm]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x35/16",
"cells": [
"Cu",
"RM",
"0.16",
"19.5",
"0.524",
"5.5",
"200",
"189",
"5",
"2.1",
"420",
"28",
"948"
]
},
{
"configuration": "1x50/16",
"cells": [
"Cu",
"RM",
"0.17",
"20.5",
"0.387",
"5.5",
"239",
"222",
"7.1",
"2.1",
"435",
"29",
"1078"
]
},
{
"configuration": "1x70/16",
"cells": [
"Cu",
"RM",
"0.19",
"22.1",
"0.268",
"5.5",
"297",
"271",
"10",
"2.1",
"465",
"31",
"1315"
]
},
{
"configuration": "1x95/16",
"cells": [
"Cu",
"RM",
"0.21",
"23.6",
"0.193",
"5.5",
"361",
"323",
"13.6",
"2.1",
"480",
"32",
"1579"
]
},
{
"configuration": "1x120/16",
"cells": [
"Cu",
"RM",
"0.23",
"25.1",
"0.153",
"5.5",
"416",
"367",
"17.1",
"2.1",
"510",
"34",
"1861"
]
},
{
"configuration": "1x150/25",
"cells": [
"Cu",
"RM",
"0.25",
"26.5",
"0.124",
"5.5",
"470",
"409",
"21.4",
"2.1",
"525",
"35",
"2212"
]
},
{
"configuration": "1x185/25",
"cells": [
"Cu",
"RM",
"0.27",
"28.1",
"0.099",
"5.5",
"538",
"461",
"26.4",
"2.1",
"555",
"37",
"2585"
]
},
{
"configuration": "1x240/25",
"cells": [
"Cu",
"RM",
"0.3",
"30.6",
"0.075",
"5.5",
"634",
"532",
"34.3",
"2.1",
"585",
"39",
"3181"
]
},
{
"configuration": "1x300/25",
"cells": [
"Cu",
"RM",
"0.33",
"33",
"0.06",
"5.5",
"724",
"599",
"42.9",
"2.1",
"630",
"42",
"3763"
]
},
{
"configuration": "1x400/35",
"cells": [
"Cu",
"RM",
"0.36",
"35.6",
"0.047",
"5.5",
"829",
"671",
"57.2",
"2.1",
"660",
"44",
"4795"
]
},
{
"configuration": "1x500/35",
"cells": [
"Cu",
"RM",
"0.43",
"38.8",
"0.037",
"5.5",
"953",
"754",
"71.4",
"2.1",
"705",
"47",
"5872"
]
}
]
},
{
"voltageLabel": "18/30 kV",
"metaItems": [
{
"label": "Voltage",
"value": "18/30 kV"
},
{
"label": "Test voltage",
"value": "63",
"unit": "kV"
},
{
"label": "Operating temperature range",
"value": "-35-+90",
"unit": "°C"
},
{
"label": "Conductor temperature (max.)",
"value": "+90",
"unit": "°C"
},
{
"label": "Short-circuit temperature (max.)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimum laying temperature",
"value": "-20",
"unit": "°C"
},
{
"label": "Minimum storage temperature",
"value": "-35",
"unit": "°C"
},
{
"label": "CPR class",
"value": "Fca",
"unit": ""
},
{
"label": "Flame retardant",
"value": "no",
"unit": ""
}
],
"columns": [
{
"key": "Cond",
"label": "Cond."
},
{
"key": "shape",
"label": "Shape"
},
{
"key": "cap",
"label": "Cap [uF/km]"
},
{
"key": "DI",
"label": "DI [mm]"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Wi",
"label": "Wi [mm]"
},
{
"key": "Ibl",
"label": "Ibl [A]"
},
{
"key": "Ibe",
"label": "Ibe [A]"
},
{
"key": "Ik_cond",
"label": "Ik [kA]"
},
{
"key": "Wm",
"label": "Wm [mm]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x50/16",
"cells": [
"Cu",
"RM",
"0.13",
"25.5",
"0.387",
"8",
"241",
"225",
"7.1",
"2.1",
"510",
"34",
"1292"
]
},
{
"configuration": "1x70/16",
"cells": [
"Cu",
"RM",
"0.15",
"27.1",
"0.268",
"8",
"299",
"274",
"10",
"2.1",
"540",
"36",
"1542"
]
},
{
"configuration": "1x95/16",
"cells": [
"Cu",
"RM",
"0.16",
"28.6",
"0.193",
"8",
"363",
"327",
"13.6",
"2.1",
"555",
"37",
"1817"
]
},
{
"configuration": "1x120/16",
"cells": [
"Cu",
"RM",
"0.17",
"30.1",
"0.153",
"8",
"418",
"371",
"17.1",
"2.1",
"585",
"39",
"2110"
]
},
{
"configuration": "1x150/25",
"cells": [
"Cu",
"RM",
"0.19",
"31.5",
"0.124",
"8",
"472",
"414",
"21.4",
"2.1",
"600",
"40",
"2473"
]
},
{
"configuration": "1x185/25",
"cells": [
"Cu",
"RM",
"0.2",
"33.1",
"0.099",
"8",
"539",
"466",
"26.4",
"2.1",
"630",
"42",
"2853"
]
},
{
"configuration": "1x240/25",
"cells": [
"Cu",
"RM",
"0.22",
"35.6",
"0.075",
"8",
"635",
"539",
"34.3",
"2.1",
"660",
"44",
"3467"
]
},
{
"configuration": "1x300/25",
"cells": [
"Cu",
"RM",
"0.24",
"38",
"0.06",
"8",
"725",
"606",
"42.9",
"2.1",
"705",
"47",
"4164"
]
},
{
"configuration": "1x400/35",
"cells": [
"Cu",
"RM",
"0.26",
"40.6",
"0.047",
"8",
"831",
"680",
"57.2",
"2.1",
"735",
"49",
"5131"
]
},
{
"configuration": "1x500/35",
"cells": [
"Cu",
"RM",
"0.29",
"43.8",
"0.037",
"8",
"953",
"765",
"71.4",
"2.4",
"795",
"53",
"6234"
]
}
]
}
]
}} />}>
<section>
<h3 data-start="451" data-end="502">For underground installation and demanding environments</h3>
<p data-start="504" data-end="901">The <strong data-start="508" data-end="518">N2XS2Y</strong> complies with the standards <strong data-start="538" data-end="558">DIN VDE 0276-620</strong>, <strong data-start="560" data-end="573">HD 620 S2</strong> and <strong data-start="578" data-end="591">IEC 60502</strong>. It is suitable for <strong data-start="612" data-end="725">installation indoors, in cable ducts, outdoors, in water, on cable trays, and especially underground</strong>. Thanks to its robust sheath, it is frequently used in <strong data-start="788" data-end="841">industrial plants, power stations, and switching stations</strong>, where stability and durability are essential.</p>
<h3 data-start="903" data-end="926">Technical construction</h3>
<p data-start="928" data-end="1367">The conductor consists of <strong data-start="951" data-end="984">bare, multi-stranded copper</strong> (Class2), surrounded by an <strong data-start="1015" data-end="1038">inner conductive layer</strong> and <strong data-start="1049" data-end="1067">XLPE insulation</strong> with a tightly bonded outer conductive layer. The shielding is provided by a <strong data-start="1141" data-end="1187">copper wire braid with counter helix</strong>. Additionally, the cable includes a <strong data-start="1224" data-end="1250">conductive tape</strong> and features a <strong data-start="1278" data-end="1301">black PE sheath</strong> (Type DMP2) that protects against moisture and mechanical abrasion.</p>
<h3 data-start="1369" data-end="1402">Features and application benefits</h3>
<p data-start="1404" data-end="1766">The N2XS2Y is <strong data-start="1419" data-end="1435">suitable for underground installation</strong>, <strong data-start="1437" data-end="1465">free from silicone and cadmium</strong>, and <strong data-start="1472" data-end="1493">not flame-retardant</strong>. It is rated for <strong data-start="1523" data-end="1544">+90°C in operation</strong> and <strong data-start="1549" data-end="1579">+250°C under short-circuit conditions</strong>. Thanks to its <strong data-start="1603" data-end="1635">partial discharge-free design</strong>, it offers a high level of safety and is particularly well-suited for networks with heavy load and challenging routing conditions.</p>
</section>
</ProductTabs>