Files
klz-cables.com/data/products/en/n2xfkld2y.mdx
2026-01-29 15:45:35 +01:00

233 lines
5.9 KiB
Plaintext
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
---
title: N2X(F)KLD2Y
sku: N2X(F)KLD2Y-high-voltage-cables-2
description: >
The N2X(F)KLD2Y-high-voltage-cables-2 series is designed for high-voltage
applications, utilizing stranded copper conductors and XLPE insulation to
ensure high ampacity and robust performance in industrial settings.
categories:
- High Voltage Cables
images: []
application: >
The N2X(F)KLD2Y-high-voltage-cables-2 series is engineered to meet the rigorous
demands of high-voltage power transmission with a focus on durability, efficiency,
and safety. This series is ideal for applications requiring high dielectric
strength and excellent thermal cycling resistance.
locale: en
---
<ProductTabs technicalData={<ProductTechnicalData data={{
"technicalItems": [
{
"label": "Rated voltage (kV)",
"value": "64/110",
"unit": "kV"
}
],
"voltageTables": [
{
"voltageLabel": "64/110 kV",
"metaItems": [
{
"label": "Voltage",
"value": "64/110 kV"
}
],
"columns": [
{
"key": "Cond",
"label": "Cond."
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Wi",
"label": "Wi [mm]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1×240RM",
"cells": [
"Cu",
"0.1",
"16.5",
"2.2",
"86",
"7040"
]
},
{
"configuration": "1×300RM",
"cells": [
"Cu",
"0.08",
"15.5",
"2.2",
"86",
"7550"
]
},
{
"configuration": "1×400RM",
"cells": [
"Cu",
"0.06",
"14.5",
"2.2",
"88",
"8380"
]
},
{
"configuration": "1×500RM",
"cells": [
"Cu",
"0.05",
"14",
"2.2",
"91",
"9530"
]
},
{
"configuration": "1×630RM",
"cells": [
"Cu",
"0.04",
"14",
"2.4",
"95",
"11190"
]
},
{
"configuration": "1×800RM",
"cells": [
"Cu",
"0.03",
"14",
"2.5",
"100",
"13160"
]
},
{
"configuration": "1×1000RM",
"cells": [
"Cu",
"0.03",
"14",
"2.6",
"104",
"15380"
]
},
{
"configuration": "1×1200RMS",
"cells": [
"Cu",
"0.02",
"14",
"2.8",
"110",
"17790"
]
},
{
"configuration": "1×1400RMS",
"cells": [
"Cu",
"0.02",
"14",
"2.9",
"115",
"19870"
]
},
{
"configuration": "1×1600RMS",
"cells": [
"Cu",
"0.02",
"14",
"3",
"119",
"22210"
]
},
{
"configuration": "1×1800RMS",
"cells": [
"Cu",
"0.02",
"14",
"3.1",
"122",
"24720"
]
},
{
"configuration": "1×2000RMS",
"cells": [
"Cu",
"0.02",
"14",
"3.1",
"124",
"26340"
]
},
{
"configuration": "1×2500RMS",
"cells": [
"Cu",
"0.01",
"14.5",
"3.3",
"134",
"31880"
]
}
]
}
]
}} />}>
<section>
<h2>Engineering Overview</h2>
<p>The <strong>N2X(F)KLD2Y-high-voltage-cables-2 series</strong> is engineered to meet the rigorous demands of high-voltage power transmission with a focus on durability, efficiency, and safety. This series is ideal for applications requiring high dielectric strength and excellent thermal cycling resistance.</p>
</section>
<section>
<h2>Technical Performance and Installation</h2>
<p>This cable series is designed to optimize both electrical and thermal performance, making it suitable for a variety of installation environments:</p>
<ul>
<li>High <strong>ampacity</strong> to support increased power transmission over long distances without significant power losses.</li>
<li>Excellent <strong>fault current withstand</strong> capability, ensuring reliability and safety in the event of abnormal current flow.</li>
<li>Designed for <strong>direct burial</strong>, <strong>trefoil formation</strong>, or <strong>cable tray mounting</strong>, providing flexibility in installation methods to suit different site conditions.</li>
</ul>
</section>
<section>
<h2>Compliance and EMC Considerations</h2>
<p>The cable's construction adheres to stringent <strong>IEC standards</strong> and carries the <strong>CE marking</strong>, affirming its compliance with the Construction Products Regulation (<strong>CPR classification</strong>). Furthermore, it is designed to minimize electromagnetic interference:</p>
<ul>
<li>Advanced insulation and shielding techniques reduce <strong>induced voltage</strong>, enhancing <strong>electromagnetic compatibility</strong> (EMC).</li>
<li>Metallic screens incorporated into the cable design help in mitigating external electromagnetic influences, ensuring stable and uninterrupted operation.</li>
</ul>
</section>
</ProductTabs>