title: N2XS(FL)2Y
sku: N2XS(FL)2Y-medium-voltage-cables
description: >
Das N2XS(FL)2Y Kabel ist ein längswasserdichtes Mittelspannungskabel mit
Kupferleiter, VPE-Isolation und fest verschweißtem Al/PE-Mantel. Es bietet
maximale Betriebssicherheit für kritische Infrastrukturen und schützt
zuverlässig gegen eindringende Feuchtigkeit.
categories:
- Mittelspannungskabel
images:
- /uploads/2025/01/N2XSFL2Y-2-scaled.webp
application: >
Das N2XS(FL)2Y erfüllt die Standards DIN VDE 0276-620, HD 620 S2 und IEC 60502. Es
eignet sich hervorragend für die Verlegung in Innenräumen, Kabelkanälen, im Freien, in
Erde, im Wasser sowie auf Kabelpritschen insbesondere in EVU-Netzen,
Industrieanlagen und Schaltstationen, wo erhöhte Anforderungen an mechanische
Belastbarkeit und Wasserdichtigkeit bestehen.
locale: de
---
<ProductTabs technicalData={<ProductTechnicalData data={{
"technicalItems": [
{
"label": "CPR class",
"value": "Fca",
"unit": ""
},
{
"label": "Flame retardant",
"value": "no",
"unit": ""
},
{
"label": "Maximal operating conductor temperature (°C)",
"value": "+90",
"unit": "°C"
},
{
"label": "Maximal short-circuit temperature (°C)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimal storage temperature (°C)",
"value": "-35",
"unit": "°C"
},
{
"label": "Minimal temperature for laying (°C)",
"value": "-20",
"unit": "°C"
},
{
"label": "Shape of conductor",
"value": "RM",
"unit": ""
}
],
"voltageTables": [
{
"voltageLabel": "6/10 kV",
"metaItems": [
{
"label": "Spannung",
"value": "6/10 kV"
},
{
"label": "Prüfspannung",
"value": "21",
"unit": "kV"
},
{
"label": "Temperaturbereich",
"value": "-35-+90",
"unit": "°C"
},
{
"label": "Leitertemperatur (max.)",
"value": "+90",
"unit": "°C"
},
{
"label": "Kurzschlusstemperatur (max.)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimale Verlegetemperatur",
"value": "-20",
"unit": "°C"
},
{
"label": "Minimale Lagertemperatur",
"value": "-35",
"unit": "°C"
},
{
"label": "CPR-Klasse",
"value": "Fca",
"unit": ""
},
{
"label": "Flammhemmend",
"value": "no",
"unit": ""
}
],
"columns": [
{
"key": "Cond",
"label": "Leiter"
},
{
"key": "shape",
"label": "Form"
},
{
"key": "cap",
"label": "Cap [uF/km]"
},
{
"key": "DI",
"label": "DI [mm]"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Wi",
"label": "Wi [mm]"
},
{
"key": "Ibl",
"label": "Ibl [A]"
},
{
"key": "Ibe",
"label": "Ibe [A]"
},
{
"key": "Ik_cond",
"label": "Ik [kA]"
},
{
"key": "Wm",
"label": "Wm [mm]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x50/16",
"cells": [
"Cu",
"RM",
"0,24",
"16,3",
"0,387",
"3,4",
"238",
"220",
"7,1",
"2,1",
"520",
"26",
"1010"
]
},
{
"configuration": "1x70/16",
"cells": [
"Cu",
"RM",
"0,28",
"17,9",
"0,268",
"3,4",
"294",
"268",
"10",
"2,1",
"560",
"28",
"1238"
]
},
{
"configuration": "1x95/16",
"cells": [
"Cu",
"RM",
"0,3",
"19,4",
"0,193",
"3,4",
"358",
"320",
"13,6",
"2,1",
"580",
"29",
"1495"
]
},
{
"configuration": "1x120/16",
"cells": [
"Cu",
"RM",
"0,34",
"20,9",
"0,153",
"3,4",
"413",
"363",
"17,1",
"2,1",
"620",
"31",
"1773"
]
},
{
"configuration": "1x150/25",
"cells": [
"Cu",
"RM",
"0,36",
"22,3",
"0,124",
"3,4",
"468",
"405",
"21,4",
"2,1",
"640",
"32",
"2119"
]
},
{
"configuration": "1x185/25",
"cells": [
"Cu",
"RM",
"0,4",
"23,9",
"0,099",
"3,4",
"535",
"456",
"26,4",
"2,1",
"680",
"34",
"2483"
]
},
{
"configuration": "1x240/25",
"cells": [
"Cu",
"RM",
"0,44",
"26,4",
"0,075",
"3,4",
"631",
"526",
"34,3",
"2,1",
"720",
"36",
"3073"
]
},
{
"configuration": "1x300/25",
"cells": [
"Cu",
"RM",
"0,48",
"28,8",
"0,06",
"3,4",
"722",
"591",
"42,9",
"2,1",
"780",
"39",
"3737"
]
},
{
"configuration": "1x400/35",
"cells": [
"Cu",
"RM",
"0,54",
"31,4",
"0,047",
"3,4",
"827",
"662",
"57,2",
"2,1",
"840",
"42",
"4697"
]
},
{
"configuration": "1x500/35",
"cells": [
"Cu",
"RM",
"0,61",
"34,6",
"0,037",
"3,4",
"949",
"744",
"71,4",
"2,1",
"880",
"44",
"5729"
]
}
]
},
{
"voltageLabel": "12/20 kV",
"metaItems": [
{
"label": "Spannung",
"value": "12/20 kV"
},
{
"label": "Prüfspannung",
"value": "42",
"unit": "kV"
},
{
"label": "Temperaturbereich",
"value": "-35 - + 90 / -35 - +90",
"unit": "°C"
},
{
"label": "Leitertemperatur (max.)",
"value": "+90",
"unit": "°C"
},
{
"label": "Kurzschlusstemperatur (max.)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimale Verlegetemperatur",
"value": "-20",
"unit": "°C"
},
{
"label": "Minimale Lagertemperatur",
"value": "-35",
"unit": "°C"
},
{
"label": "CPR-Klasse",
"value": "Fca",
"unit": ""
},
{
"label": "Flammhemmend",
"value": "no",
"unit": ""
}
],
"columns": [
{
"key": "Cond",
"label": "Leiter"
},
{
"key": "shape",
"label": "Form"
},
{
"key": "cap",
"label": "Cap [uF/km]"
},
{
"key": "DI",
"label": "DI [mm]"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Wi",
"label": "Wi [mm]"
},
{
"key": "Ibl",
"label": "Ibl [A]"
},
{
"key": "Ibe",
"label": "Ibe [A]"
},
{
"key": "Ik_cond",
"label": "Ik [kA]"
},
{
"key": "Wm",
"label": "Wm [mm]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x50/16",
"cells": [
"Cu",
"RM",
"0,17",
"20,5",
"0,387",
"5,5",
"239",
"222",
"7,1",
"2,1",
"600",
"30",
"1166"
]
},
{
"configuration": "1x70/16",
"cells": [
"Cu",
"RM",
"0,19",
"22,1",
"0,268",
"5,5",
"297",
"271",
"10",
"2,1",
"640",
"32",
"1409"
]
},
{
"configuration": "1x95/16",
"cells": [
"Cu",
"RM",
"0,21",
"23,6",
"0,193",
"5,5",
"361",
"323",
"13,6",
"2,1",
"660",
"33",
"1675"
]
},
{
"configuration": "1x120/16",
"cells": [
"Cu",
"RM",
"0,23",
"25,1",
"0,153",
"5,5",
"416",
"367",
"17,1",
"2,1",
"700",
"35",
"1968"
]
},
{
"configuration": "1x150/25",
"cells": [
"Cu",
"RM",
"0,25",
"26,5",
"0,124",
"5,5",
"470",
"409",
"21,4",
"2,1",
"720",
"36",
"2320"
]
},
{
"configuration": "1x185/25",
"cells": [
"Cu",
"RM",
"0,27",
"28,1",
"0,099",
"5,5",
"538",
"461",
"26,4",
"2,1",
"760",
"38",
"2697"
]
},
{
"configuration": "1x240/25",
"cells": [
"Cu",
"RM",
"0,3",
"30,6",
"0,075",
"5,5",
"634",
"532",
"34,3",
"2,1",
"800",
"40",
"3303"
]
},
{
"configuration": "1x300/25",
"cells": [
"Cu",
"RM",
"0,32",
"33",
"0,06",
"5,5",
"724",
"599",
"42,9",
"2,1",
"860",
"43",
"3978"
]
},
{
"configuration": "1x400/35",
"cells": [
"Cu",
"RM",
"0,36",
"35,6",
"0,047",
"5,5",
"829",
"671",
"57,2",
"2,1",
"900",
"45",
"4925"
]
},
{
"configuration": "1x500/35",
"cells": [
"Cu",
"RM",
"0,4",
"38,8",
"0,037",
"5,5",
"953",
"754",
"71,4",
"2,1",
"980",
"49",
"6006"
]
}
]
},
{
"voltageLabel": "18/30 kV",
"metaItems": [
{
"label": "Spannung",
"value": "18/30 kV"
},
{
"label": "Prüfspannung",
"value": "63",
"unit": "kV"
},
{
"label": "Temperaturbereich",
"value": "-35-+90",
"unit": "°C"
},
{
"label": "Leitertemperatur (max.)",
"value": "+90",
"unit": "°C"
},
{
"label": "Kurzschlusstemperatur (max.)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimale Verlegetemperatur",
"value": "-20",
"unit": "°C"
},
{
"label": "Minimale Lagertemperatur",
"value": "-35",
"unit": "°C"
},
{
"label": "CPR-Klasse",
"value": "Fca",
"unit": ""
},
{
"label": "Flammhemmend",
"value": "no",
"unit": ""
}
],
"columns": [
{
"key": "Cond",
"label": "Leiter"
},
{
"key": "shape",
"label": "Form"
},
{
"key": "cap",
"label": "Cap [uF/km]"
},
{
"key": "DI",
"label": "DI [mm]"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Wi",
"label": "Wi [mm]"
},
{
"key": "Ibl",
"label": "Ibl [A]"
},
{
"key": "Ibe",
"label": "Ibe [A]"
},
{
"key": "Ik_cond",
"label": "Ik [kA]"
},
{
"key": "Wm",
"label": "Wm [mm]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x50/16",
"cells": [
"Cu",
"RM",
"0,13",
"25,5",
"0,387",
"8",
"241",
"225",
"7,1",
"2,1",
"700",
"35",
"1405"
]
},
{
"configuration": "1x70/16",
"cells": [
"Cu",
"RM",
"0,15",
"27,1",
"0,268",
"8",
"299",
"274",
"10",
"2,1",
"740",
"37",
"1646"
]
},
{
"configuration": "1x95/16",
"cells": [
"Cu",
"RM",
"0,16",
"28,6",
"0,193",
"8",
"363",
"327",
"13,6",
"2,1",
"760",
"38",
"1926"
]
},
{
"configuration": "1x120/16",
"cells": [
"Cu",
"RM",
"0,17",
"30,1",
"0,153",
"8",
"418",
"371",
"17,1",
"2,1",
"800",
"40",
"2227"
]
},
{
"configuration": "1x150/25",
"cells": [
"Cu",
"RM",
"0,19",
"31,5",
"0,124",
"8",
"472",
"414",
"21,4",
"2,1",
"820",
"41",
"2590"
]
},
{
"configuration": "1x185/25",
"cells": [
"Cu",
"RM",
"0,2",
"33,1",
"0,099",
"8",
"539",
"466",
"26,4",
"2,1",
"860",
"43",
"2975"
]
},
{
"configuration": "1x240/25",
"cells": [
"Cu",
"RM",
"0,22",
"35,6",
"0,075",
"8",
"635",
"539",
"34,3",
"2,1",
"900",
"45",
"3594"
]
},
{
"configuration": "1x300/25",
"cells": [
"Cu",
"RM",
"0,24",
"38",
"0,06",
"8",
"725",
"606",
"42,9",
"2,1",
"960",
"48",
"4300"
]
},
{
"configuration": "1x400/35",
"cells": [
"Cu",
"RM",
"0,26",
"40,6",
"0,047",
"8",
"831",
"680",
"57,2",
"2,1",
"1020",
"51",
"5290"
]
},
{
"configuration": "1x500/35",
"cells": [
"Cu",
"RM",
"0,29",
"43,8",
"0,037",
"8",
"953",
"765",
"71,4",
"2,4",
"1080",
"54",
"6403"
]
}
]
}
]
}} />}>
<section>
<h3 data-start="483" data-end="530">Für anspruchsvolle Energieverteilungsnetze</h3>
<p data-start="532" data-end="920">Das <strong data-start="536" data-end="550">N2XS(FL)2Y</strong> erfüllt die Standards <strong data-start="573" data-end="593">DIN VDE 0276-620</strong>, <strong data-start="595" data-end="608">HD 620 S2</strong> und <strong data-start="613" data-end="626">IEC 60502</strong>. Es eignet sich hervorragend für die <strong data-start="664" data-end="762">Verlegung in Innenräumen, Kabelkanälen, im Freien, in Erde, im Wasser sowie auf Kabelpritschen</strong> insbesondere in <strong data-start="781" data-end="833">EVU-Netzen, Industrieanlagen und Schaltstationen</strong>, wo erhöhte Anforderungen an mechanische Belastbarkeit und Wasserdichtigkeit bestehen.</p>
<h3 data-start="922" data-end="945">Technischer Aufbau</h3>
<p data-start="947" data-end="1455">Der Kabelaufbau basiert auf einem <strong data-start="981" data-end="1011">mehrdrähtigen Kupferleiter</strong> (Klasse 2), einer <strong data-start="1030" data-end="1047">VPE-Isolation</strong> mit extrudierter, fest haftender <strong data-start="1081" data-end="1104">äußerer Leitschicht</strong>, sowie einer <strong data-start="1118" data-end="1164">längswasserdichten, leitfähigen Bandierung</strong>. Die Abschirmung besteht aus <strong data-start="1194" data-end="1230">Kupferdrähten mit Querleitwendel</strong>, ergänzt durch eine weitere <strong data-start="1259" data-end="1291">längswasserdichte Bandierung</strong>. Der äußere Schutz wird durch eine <strong data-start="1327" data-end="1396">fest mit dem schwarzen PE-Mantel verschweißte Aluminiumbandierung</strong> realisiert sie wirkt als effektive <strong data-start="1434" data-end="1454">Querwassersperre</strong>.</p>
<h3 data-start="1457" data-end="1488">Eigenschaften und Vorteile</h3>
<p data-start="1490" data-end="1897">Das N2XS(FL)2Y ist <strong data-start="1509" data-end="1525">erdverlegbar</strong>, <strong data-start="1527" data-end="1560">für Außenanwendungen geeignet</strong> und hält <strong data-start="1570" data-end="1605">Betriebstemperaturen bis +90°C</strong> sowie <strong data-start="1612" data-end="1650">Kurzschlussbelastungen bis +250°C</strong> stand. Es ist <strong data-start="1665" data-end="1693">silikon- und cadmiumfrei</strong> und enthält keine lackbenetzungsstörenden Substanzen. Dank seines <strong data-start="1760" data-end="1792">teilentladungsfreien Aufbaus</strong> und der Al/PE-Schicht ist es bestens geeignet für <strong data-start="1843" data-end="1896">feuchte Umgebungen mit erhöhtem Sicherheitsbedarf</strong>.</p>
</section>
</ProductTabs>