Files
klz-cables.com/data/products/de/n2xsfl2y-hv.mdx
2026-01-29 15:45:35 +01:00

928 lines
20 KiB
Plaintext
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
---
title: N2XS(FL)2Y
sku: N2XS(FL)2Y-high-voltage-cables
description: >
Das N2XS(FL)2Y Kabel ist ein anpassbares Hochspannungskabel mit durchdachtem
Schutzaufbau gegen Wassereintritt und hoher elektrischer Belastbarkeit. Es
erfüllt internationale Normen und eignet sich ideal für anspruchsvolle
Energieinfrastrukturen.
categories:
- Hochspannungskabel
images:
- /uploads/2025/06/N2XSFL2Y-3-scaled.webp
application: >
Das N2XS(FL)2Y ist konzipiert für die Verlegung im Erdreich, in Kabelkanälen, in Rohren,
im Freien und in Innenräumen. Es entspricht der Norm IEC 60840 und lässt sich
individuell auf projektspezifische Anforderungen anpassen. Typisch eingesetzt wird es
in Übertragungsnetzen, Umspannwerken und großen Industrieanlagen, wo maximale
Zuverlässigkeit gefordert ist.
locale: de
---
<ProductTabs technicalData={<ProductTechnicalData data={{
"technicalItems": [
{
"label": "CPR class",
"value": "Fca",
"unit": ""
},
{
"label": "Flame retardant",
"value": "no",
"unit": ""
},
{
"label": "Maximal operating conductor temperature (°C)",
"value": "+90",
"unit": "°C"
},
{
"label": "Maximal short-circuit temperature (°C)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimal storage temperature (°C)",
"value": "-35",
"unit": "°C"
},
{
"label": "Minimal temperature for laying (°C)",
"value": "-20",
"unit": "°C"
},
{
"label": "Shape of conductor",
"value": "RM",
"unit": ""
}
],
"voltageTables": [
{
"voltageLabel": "6/10 kV",
"metaItems": [
{
"label": "Spannung",
"value": "6/10 kV"
},
{
"label": "Prüfspannung",
"value": "21",
"unit": "kV"
},
{
"label": "Temperaturbereich",
"value": "-35-+90",
"unit": "°C"
},
{
"label": "Leitertemperatur (max.)",
"value": "+90",
"unit": "°C"
},
{
"label": "Kurzschlusstemperatur (max.)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimale Verlegetemperatur",
"value": "-20",
"unit": "°C"
},
{
"label": "Minimale Lagertemperatur",
"value": "-35",
"unit": "°C"
},
{
"label": "CPR-Klasse",
"value": "Fca",
"unit": ""
},
{
"label": "Flammhemmend",
"value": "no",
"unit": ""
}
],
"columns": [
{
"key": "Cond",
"label": "Leiter"
},
{
"key": "shape",
"label": "Form"
},
{
"key": "cap",
"label": "Cap [uF/km]"
},
{
"key": "DI",
"label": "DI [mm]"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Wi",
"label": "Wi [mm]"
},
{
"key": "Ibl",
"label": "Ibl [A]"
},
{
"key": "Ibe",
"label": "Ibe [A]"
},
{
"key": "Ik_cond",
"label": "Ik [kA]"
},
{
"key": "Wm",
"label": "Wm [mm]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x50/16",
"cells": [
"Cu",
"RM",
"0,24",
"16,3",
"0,387",
"3,4",
"238",
"220",
"7,1",
"2,1",
"520",
"26",
"1010"
]
},
{
"configuration": "1x70/16",
"cells": [
"Cu",
"RM",
"0,28",
"17,9",
"0,268",
"3,4",
"294",
"268",
"10",
"2,1",
"560",
"28",
"1238"
]
},
{
"configuration": "1x95/16",
"cells": [
"Cu",
"RM",
"0,3",
"19,4",
"0,193",
"3,4",
"358",
"320",
"13,6",
"2,1",
"580",
"29",
"1495"
]
},
{
"configuration": "1x120/16",
"cells": [
"Cu",
"RM",
"0,34",
"20,9",
"0,153",
"3,4",
"413",
"363",
"17,1",
"2,1",
"620",
"31",
"1773"
]
},
{
"configuration": "1x150/25",
"cells": [
"Cu",
"RM",
"0,36",
"22,3",
"0,124",
"3,4",
"468",
"405",
"21,4",
"2,1",
"640",
"32",
"2119"
]
},
{
"configuration": "1x185/25",
"cells": [
"Cu",
"RM",
"0,4",
"23,9",
"0,099",
"3,4",
"535",
"456",
"26,4",
"2,1",
"680",
"34",
"2483"
]
},
{
"configuration": "1x240/25",
"cells": [
"Cu",
"RM",
"0,44",
"26,4",
"0,075",
"3,4",
"631",
"526",
"34,3",
"2,1",
"720",
"36",
"3073"
]
},
{
"configuration": "1x300/25",
"cells": [
"Cu",
"RM",
"0,48",
"28,8",
"0,06",
"3,4",
"722",
"591",
"42,9",
"2,1",
"780",
"39",
"3737"
]
},
{
"configuration": "1x400/35",
"cells": [
"Cu",
"RM",
"0,54",
"31,4",
"0,047",
"3,4",
"827",
"662",
"57,2",
"2,1",
"840",
"42",
"4697"
]
},
{
"configuration": "1x500/35",
"cells": [
"Cu",
"RM",
"0,61",
"34,6",
"0,037",
"3,4",
"949",
"744",
"71,4",
"2,1",
"880",
"44",
"5729"
]
}
]
},
{
"voltageLabel": "12/20 kV",
"metaItems": [
{
"label": "Spannung",
"value": "12/20 kV"
},
{
"label": "Prüfspannung",
"value": "42",
"unit": "kV"
},
{
"label": "Temperaturbereich",
"value": "-35 - + 90 / -35 - +90",
"unit": "°C"
},
{
"label": "Leitertemperatur (max.)",
"value": "+90",
"unit": "°C"
},
{
"label": "Kurzschlusstemperatur (max.)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimale Verlegetemperatur",
"value": "-20",
"unit": "°C"
},
{
"label": "Minimale Lagertemperatur",
"value": "-35",
"unit": "°C"
},
{
"label": "CPR-Klasse",
"value": "Fca",
"unit": ""
},
{
"label": "Flammhemmend",
"value": "no",
"unit": ""
}
],
"columns": [
{
"key": "Cond",
"label": "Leiter"
},
{
"key": "shape",
"label": "Form"
},
{
"key": "cap",
"label": "Cap [uF/km]"
},
{
"key": "DI",
"label": "DI [mm]"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Wi",
"label": "Wi [mm]"
},
{
"key": "Ibl",
"label": "Ibl [A]"
},
{
"key": "Ibe",
"label": "Ibe [A]"
},
{
"key": "Ik_cond",
"label": "Ik [kA]"
},
{
"key": "Wm",
"label": "Wm [mm]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x50/16",
"cells": [
"Cu",
"RM",
"0,17",
"20,5",
"0,387",
"5,5",
"239",
"222",
"7,1",
"2,1",
"600",
"30",
"1166"
]
},
{
"configuration": "1x70/16",
"cells": [
"Cu",
"RM",
"0,19",
"22,1",
"0,268",
"5,5",
"297",
"271",
"10",
"2,1",
"640",
"32",
"1409"
]
},
{
"configuration": "1x95/16",
"cells": [
"Cu",
"RM",
"0,21",
"23,6",
"0,193",
"5,5",
"361",
"323",
"13,6",
"2,1",
"660",
"33",
"1675"
]
},
{
"configuration": "1x120/16",
"cells": [
"Cu",
"RM",
"0,23",
"25,1",
"0,153",
"5,5",
"416",
"367",
"17,1",
"2,1",
"700",
"35",
"1968"
]
},
{
"configuration": "1x150/25",
"cells": [
"Cu",
"RM",
"0,25",
"26,5",
"0,124",
"5,5",
"470",
"409",
"21,4",
"2,1",
"720",
"36",
"2320"
]
},
{
"configuration": "1x185/25",
"cells": [
"Cu",
"RM",
"0,27",
"28,1",
"0,099",
"5,5",
"538",
"461",
"26,4",
"2,1",
"760",
"38",
"2697"
]
},
{
"configuration": "1x240/25",
"cells": [
"Cu",
"RM",
"0,3",
"30,6",
"0,075",
"5,5",
"634",
"532",
"34,3",
"2,1",
"800",
"40",
"3303"
]
},
{
"configuration": "1x300/25",
"cells": [
"Cu",
"RM",
"0,32",
"33",
"0,06",
"5,5",
"724",
"599",
"42,9",
"2,1",
"860",
"43",
"3978"
]
},
{
"configuration": "1x400/35",
"cells": [
"Cu",
"RM",
"0,36",
"35,6",
"0,047",
"5,5",
"829",
"671",
"57,2",
"2,1",
"900",
"45",
"4925"
]
},
{
"configuration": "1x500/35",
"cells": [
"Cu",
"RM",
"0,4",
"38,8",
"0,037",
"5,5",
"953",
"754",
"71,4",
"2,1",
"980",
"49",
"6006"
]
}
]
},
{
"voltageLabel": "18/30 kV",
"metaItems": [
{
"label": "Spannung",
"value": "18/30 kV"
},
{
"label": "Prüfspannung",
"value": "63",
"unit": "kV"
},
{
"label": "Temperaturbereich",
"value": "-35-+90",
"unit": "°C"
},
{
"label": "Leitertemperatur (max.)",
"value": "+90",
"unit": "°C"
},
{
"label": "Kurzschlusstemperatur (max.)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimale Verlegetemperatur",
"value": "-20",
"unit": "°C"
},
{
"label": "Minimale Lagertemperatur",
"value": "-35",
"unit": "°C"
},
{
"label": "CPR-Klasse",
"value": "Fca",
"unit": ""
},
{
"label": "Flammhemmend",
"value": "no",
"unit": ""
}
],
"columns": [
{
"key": "Cond",
"label": "Leiter"
},
{
"key": "shape",
"label": "Form"
},
{
"key": "cap",
"label": "Cap [uF/km]"
},
{
"key": "DI",
"label": "DI [mm]"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Wi",
"label": "Wi [mm]"
},
{
"key": "Ibl",
"label": "Ibl [A]"
},
{
"key": "Ibe",
"label": "Ibe [A]"
},
{
"key": "Ik_cond",
"label": "Ik [kA]"
},
{
"key": "Wm",
"label": "Wm [mm]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x50/16",
"cells": [
"Cu",
"RM",
"0,13",
"25,5",
"0,387",
"8",
"241",
"225",
"7.1",
"2,1",
"700",
"35",
"1405"
]
},
{
"configuration": "1x70/16",
"cells": [
"Cu",
"RM",
"0,15",
"27,1",
"0,268",
"8",
"299",
"274",
"10",
"2,1",
"740",
"37",
"1646"
]
},
{
"configuration": "1x95/16",
"cells": [
"Cu",
"RM",
"0,16",
"28,6",
"0,193",
"8",
"363",
"327",
"13,6",
"2,1",
"760",
"38",
"1926"
]
},
{
"configuration": "1x120/16",
"cells": [
"Cu",
"RM",
"0,17",
"30,1",
"0,153",
"8",
"418",
"371",
"17,1",
"2,1",
"800",
"40",
"2227"
]
},
{
"configuration": "1x150/25",
"cells": [
"Cu",
"RM",
"0,19",
"31,5",
"0,124",
"8",
"472",
"414",
"21,4",
"2,1",
"820",
"41",
"2590"
]
},
{
"configuration": "1x185/25",
"cells": [
"Cu",
"RM",
"0,2",
"33,1",
"0,099",
"8",
"539",
"466",
"26,4",
"2,1",
"860",
"43",
"2975"
]
},
{
"configuration": "1x240/25",
"cells": [
"Cu",
"RM",
"0,22",
"35,6",
"0,075",
"8",
"635",
"539",
"34,3",
"2,1",
"900",
"45",
"3594"
]
},
{
"configuration": "1x300/25",
"cells": [
"Cu",
"RM",
"0,24",
"38",
"0,06",
"8",
"725",
"606",
"42,9",
"2,1",
"960",
"48",
"4300"
]
},
{
"configuration": "1x400/35",
"cells": [
"Cu",
"RM",
"0,26",
"40,6",
"0,047",
"8",
"831",
"680",
"57,2",
"2,1",
"1020",
"51",
"5290"
]
},
{
"configuration": "1x500/35",
"cells": [
"Cu",
"RM",
"0,29",
"43,8",
"0,037",
"8",
"953",
"765",
"71,4",
"2,4",
"1080",
"54",
"6403"
]
}
]
}
]
}} />}>
<section>
<h3 data-start="508" data-end="571">Flexibel im Einsatz unter Erde, Wasser und auf Pritschen</h3>
<p data-start="573" data-end="950">Das <strong data-start="577" data-end="591">N2XS(FL)2Y</strong> ist konzipiert für die <strong data-start="615" data-end="698">Verlegung im Erdreich, in Kabelkanälen, in Rohren, im Freien und in Innenräumen</strong>. Es entspricht der Norm <strong data-start="723" data-end="736">IEC 60840</strong> und lässt sich individuell auf projektspezifische Anforderungen anpassen. Typisch eingesetzt wird es in <strong data-start="841" data-end="906">Übertragungsnetzen, Umspannwerken und großen Industrieanlagen</strong>, wo maximale Zuverlässigkeit gefordert ist.</p>
<h3 data-start="952" data-end="975">Technischer Aufbau</h3>
<p data-start="977" data-end="1539">Das Kabel verfügt über einen <strong data-start="1006" data-end="1062">mehrdrähtigen Kupferleiter (Klasse 2 nach IEC 60228)</strong>. Die Isolation besteht aus <strong data-start="1090" data-end="1123">vernetztem Polyethylen (XLPE)</strong>, eingebettet zwischen einer <strong data-start="1152" data-end="1180">leitfähigen Innenschicht</strong> und einer <strong data-start="1191" data-end="1232">leitfähigen äußeren Isolationsschicht</strong>. Eine <strong data-start="1239" data-end="1265">quellfähige Bandierung</strong> sorgt gemeinsam mit <strong data-start="1286" data-end="1334">Kupferdrähten und einer offenen Kupferwendel</strong> für eine effektive Abschirmung. Der Außenmantel besteht aus <strong data-start="1395" data-end="1401">PE</strong>, das mit einer <strong data-start="1417" data-end="1451">Aluminiumkaschierung (Alucopo)</strong> fest verbunden ist optimaler Schutz gegen <strong data-start="1496" data-end="1538">mechanische Belastung und Feuchtigkeit</strong>.</p>
<h3 data-start="1541" data-end="1561">Einsatzmerkmale</h3>
<p data-start="1563" data-end="1902">Das N2XS(FL)2Y ist <strong data-start="1582" data-end="1611">wasserdicht, erdverlegbar</strong> und mechanisch belastbar und dank seiner <strong data-start="1655" data-end="1700">mehrschichtigen Schirm- und Quellstruktur</strong> besonders für kritische Hochspannungsanwendungen geeignet. Die elektrische Leistungsfähigkeit wird projektbezogen berechnet so lässt sich das Kabel exakt an die Anforderungen im Netzbetrieb anpassen.</p>
</section>
</ProductTabs>