title: N2XS(F)2Y
sku: N2XS(F)2Y-medium-voltage-cables
description: >
Das N2XS(F)2Y Kabel ist ein längswasserdichtes Mittelspannungskabel mit
Kupferleiter, VPE-Isolation und widerstandsfähigem PE-Mantel. Es kombiniert
hohe elektrische Sicherheit mit robuster Außenschicht für anspruchsvolle
Anwendungen im Netzbetrieb.
categories:
- Mittelspannungskabel
images:
- /uploads/2025/01/N2XSF2Y-3-scaled.webp
application: >
Das N2XS(F)2Y erfüllt die gängigen Normen DIN VDE 0276-620, HD 620 S2 und IEC 60502 und
ist für die Verlegung in Innenräumen, Kabelkanälen, im Freien, in Wasser, Erde und auf
Kabelpritschen geeignet. Besonders in EVU-Netzen, Industrieanlagen und Kraftwerken
spielt dieses Kabel seine Stärken aus überall dort, wo Langlebigkeit,
Wasserdichtigkeit und Sicherheit gefragt sind.
locale: de
---
<ProductTabs technicalData={<ProductTechnicalData data={{
"technicalItems": [
{
"label": "CPR class",
"value": "Fca",
"unit": ""
},
{
"label": "Flame retardant",
"value": "no",
"unit": ""
},
{
"label": "Isolationsdicke (nom.) (mm)",
"value": "5,5",
"unit": "mm"
},
{
"label": "Manteldicke (min.) (mm)",
"value": "2,1",
"unit": "mm"
},
{
"label": "Maximal operating conductor temperature (°C)",
"value": "+90",
"unit": "°C"
},
{
"label": "Maximal short-circuit temperature (°C)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimal storage temperature (°C)",
"value": "-35",
"unit": "°C"
},
{
"label": "Minimal temperature for laying (°C)",
"value": "-20",
"unit": "°C"
},
{
"label": "Nennspannung (kV)",
"value": "12/20",
"unit": "kV"
},
{
"label": "Prüfspannung (kV)",
"value": "42",
"unit": "kV"
},
{
"label": "Shape of conductor",
"value": "RM",
"unit": ""
},
{
"label": "Temperaturbereich (°C)",
"value": "-35-+90",
"unit": "°C"
}
],
"voltageTables": [
{
"voltageLabel": "12/20 kV",
"metaItems": [
{
"label": "Spannung",
"value": "12/20 kV"
},
{
"label": "Prüfspannung",
"value": "42",
"unit": "kV"
},
{
"label": "Temperaturbereich",
"value": "-35-+90",
"unit": "°C"
},
{
"label": "Leitertemperatur (max.)",
"value": "+90",
"unit": "°C"
},
{
"label": "Kurzschlusstemperatur (max.)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimale Verlegetemperatur",
"value": "-20",
"unit": "°C"
},
{
"label": "Minimale Lagertemperatur",
"value": "-35",
"unit": "°C"
},
{
"label": "CPR-Klasse",
"value": "Fca",
"unit": ""
},
{
"label": "Flammhemmend",
"value": "no",
"unit": ""
}
],
"columns": [
{
"key": "Cond",
"label": "Leiter"
},
{
"key": "shape",
"label": "Form"
},
{
"key": "cap",
"label": "Cap [uF/km]"
},
{
"key": "DI",
"label": "DI [mm]"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Wi",
"label": "Wi [mm]"
},
{
"key": "Ibl",
"label": "Ibl [A]"
},
{
"key": "Ibe",
"label": "Ibe [A]"
},
{
"key": "Ik_cond",
"label": "Ik [kA]"
},
{
"key": "Wm",
"label": "Wm [mm]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x35/16",
"cells": [
"Cu",
"RM",
"0,16",
"19,5",
"0,524",
"5,5",
"200",
"189",
"5",
"2,1",
"420",
"28",
"949"
]
},
{
"configuration": "1x50/16",
"cells": [
"Cu",
"RM",
"0,17",
"20,5",
"0,387",
"5,5",
"239",
"222",
"7,1",
"2,1",
"435",
"29",
"1079"
]
},
{
"configuration": "1x70/16",
"cells": [
"Cu",
"RM",
"0,19",
"22,1",
"0,268",
"5,5",
"297",
"271",
"10",
"2,1",
"465",
"31",
"1315"
]
},
{
"configuration": "1x95/16",
"cells": [
"Cu",
"RM",
"0,21",
"23,6",
"0,193",
"5,5",
"361",
"323",
"13,6",
"2,1",
"480",
"32",
"1580"
]
},
{
"configuration": "1x120/16",
"cells": [
"Cu",
"RM",
"0,23",
"25,1",
"0,153",
"5,5",
"416",
"367",
"17,1",
"2,1",
"510",
"34",
"1862"
]
},
{
"configuration": "1x150/25",
"cells": [
"Cu",
"RM",
"0,25",
"26,5",
"0,124",
"5,5",
"470",
"409",
"21,4",
"2,1",
"525",
"35",
"2212"
]
},
{
"configuration": "1x185/25",
"cells": [
"Cu",
"RM",
"0,27",
"28,1",
"0,099",
"5,5",
"538",
"461",
"26,4",
"2,1",
"555",
"37",
"2585"
]
},
{
"configuration": "1x240/25",
"cells": [
"Cu",
"RM",
"0,3",
"30,6",
"0,075",
"5,5",
"634",
"532",
"34,3",
"2,1",
"585",
"39",
"3181"
]
},
{
"configuration": "1x300/25",
"cells": [
"Cu",
"RM",
"0,33",
"33",
"0,06",
"5,5",
"724",
"599",
"42,9",
"2,1",
"630",
"42",
"3851"
]
},
{
"configuration": "1x400/35",
"cells": [
"Cu",
"RM",
"0,36",
"35,6",
"0,047",
"5,5",
"829",
"671",
"57,2",
"2,1",
"660",
"44",
"4795"
]
},
{
"configuration": "1x500/35",
"cells": [
"Cu",
"RM",
"0,4",
"38,8",
"0,037",
"5,5",
"953",
"754",
"71,4",
"2,1",
"705",
"47",
"5873"
]
}
]
}
]
}} />}>
<section>
<h3 data-start="452" data-end="502">Entwickelt für leistungsstarke Netzumgebungen</h3>
<p data-start="504" data-end="904">Das <strong data-start="508" data-end="521">N2XS(F)2Y</strong> erfüllt die gängigen Normen <strong data-start="550" data-end="570">DIN VDE 0276-620</strong>, <strong data-start="572" data-end="585">HD 620 S2</strong> und <strong data-start="590" data-end="603">IEC 60502</strong> und ist für die <strong data-start="620" data-end="713">Verlegung in Innenräumen, Kabelkanälen, im Freien, in Wasser, Erde und auf Kabelpritschen</strong> geeignet. Besonders in <strong data-start="737" data-end="785">EVU-Netzen, Industrieanlagen und Kraftwerken</strong> spielt dieses Kabel seine Stärken aus überall dort, wo Langlebigkeit, Wasserdichtigkeit und Sicherheit gefragt sind.</p>
<h3 data-start="906" data-end="946">Aufbau und technische Eigenschaften</h3>
<p data-start="948" data-end="1387">Im Inneren befindet sich ein <strong data-start="977" data-end="1016">blanker, mehrdrähtiger Kupferleiter</strong> (Klasse 2), umgeben von einer <strong data-start="1047" data-end="1123">extrudierten VPE-Isolation mit innerer und haftender äußerer Leitschicht</strong>. Eine <strong data-start="1130" data-end="1174">längswasserdichte, leitfähige Bandierung</strong>, eine <strong data-start="1181" data-end="1234">Abschirmung aus Kupferdrähten mit Querleitwendeln</strong> und eine zusätzliche <strong data-start="1256" data-end="1282">längswasserdichte Lage</strong> sichern den Aufbau. Der schwarze <strong data-start="1316" data-end="1345">PE-Außenmantel (Typ DMP2)</strong> sorgt für hohe mechanische Belastbarkeit.</p>
<h3 data-start="1389" data-end="1425">Anwendungsbereiche und Vorteile</h3>
<p data-start="1427" data-end="1822">Das N2XS(F)2Y ist <strong data-start="1445" data-end="1461">erdverlegbar</strong>, <strong data-start="1463" data-end="1509">resistent gegen aggressive Umwelteinflüsse</strong> und hält <strong data-start="1519" data-end="1562">Temperaturen bis +90°C im Dauerbetrieb</strong> sowie <strong data-start="1569" data-end="1599">+250°C im Kurzschlussfall</strong> stand. Es ist <strong data-start="1614" data-end="1663">frei von silikon- und cadmiumhaltigen Stoffen</strong> und dank des <strong data-start="1677" data-end="1709">teilentladungsfreien Aufbaus</strong> besonders geeignet für Netze mit höchsten Anforderungen an <strong data-start="1769" data-end="1803">elektrische Betriebssicherheit</strong> und Langlebigkeit.</p>
</section>
</ProductTabs>