Files
klz-cables.com/data/products/de/mittelspannungskabel/na2xs2y.mdx
Marc Mintel f7aa880d9f
Some checks failed
Build & Deploy / 🔍 Prepare (push) Successful in 1m19s
Build & Deploy / 🧪 QA (push) Failing after 3m32s
Build & Deploy / 🚀 Deploy (push) Has been skipped
Build & Deploy / 🏗️ Build (push) Failing after 7m51s
Build & Deploy / ⚡ Lighthouse (push) Has been skipped
Build & Deploy / 🧪 Smoke Test (push) Has been skipped
Build & Deploy / ♿ WCAG (push) Has been skipped
Build & Deploy / 🛡️ Quality Gates (push) Has been skipped
Build & Deploy / 🔔 Notify (push) Successful in 10s
feat: migration von directus zu payloadcms
2026-02-24 19:25:43 +01:00

1113 lines
23 KiB
Plaintext
Raw Blame History

This file contains invisible Unicode characters
This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
---
title: NA2XS2Y
sku: NA2XS2Y-medium-voltage-cables
description: >
Das NA2XS2Y Kabel ist ein hoch belastbares Mittelspannungskabel mit
Aluminiumleiter, VPE-Isolierung und widerstandsfähigem PE-Mantel. Es eignet
sich hervorragend für erdverlegte Anwendungen und überzeugt durch thermische
Belastbarkeit, mechanische Robustheit und teilentladungsfreien Aufbau.
categories:
- Mittelspannungskabel
images:
- /uploads/2025/01/NA2XS2Y-scaled.webp
application: >
Das NA2XS2Y erfüllt die Normen DIN VDE 0276-620, HD 620 S2 und IEC 60502 und ist
speziell für die feste Verlegung in Innenräumen, Kabelkanälen, im Freien, in Erde und
in Wasser ausgelegt. Es findet seinen Einsatz in Industrieanlagen, Schaltstationen
und Kraftwerken, besonders dort, wo das Kabel beim Verlegen oder im Betrieb
mechanisch stark beansprucht wird.
locale: de
---
<ProductTabs technicalData={<ProductTechnicalData data={{
"technicalItems": [
{
"label": "CPR class",
"value": "Fca",
"unit": ""
},
{
"label": "Flame retardant",
"value": "no",
"unit": ""
},
{
"label": "Maximal operating conductor temperature (°C)",
"value": "+90",
"unit": "°C"
},
{
"label": "Maximal short-circuit temperature (°C)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimal storage temperature (°C)",
"value": "-35",
"unit": "°C"
},
{
"label": "Minimal temperature for laying (°C)",
"value": "-20",
"unit": "°C"
},
{
"label": "Shape of conductor",
"value": "RM",
"unit": ""
},
{
"label": "Temperaturbereich (°C)",
"value": "-35-+90",
"unit": "°C"
}
],
"voltageTables": [
{
"voltageLabel": "6/10 kV",
"metaItems": [
{
"label": "Spannung",
"value": "6/10 kV"
},
{
"label": "Prüfspannung",
"value": "21",
"unit": "kV"
},
{
"label": "Temperaturbereich",
"value": "-35-+90",
"unit": "°C"
},
{
"label": "Leitertemperatur (max.)",
"value": "+90",
"unit": "°C"
},
{
"label": "Kurzschlusstemperatur (max.)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimale Verlegetemperatur",
"value": "-20",
"unit": "°C"
},
{
"label": "Minimale Lagertemperatur",
"value": "-35",
"unit": "°C"
},
{
"label": "CPR-Klasse",
"value": "Fca",
"unit": ""
},
{
"label": "Flammhemmend",
"value": "no",
"unit": ""
}
],
"columns": [
{
"key": "Cond",
"label": "Leiter"
},
{
"key": "shape",
"label": "Form"
},
{
"key": "cap",
"label": "Cap [uF/km]"
},
{
"key": "DI",
"label": "DI [mm]"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Wi",
"label": "Wi [mm]"
},
{
"key": "Ibl",
"label": "Ibl [A]"
},
{
"key": "Ibe",
"label": "Ibe [A]"
},
{
"key": "Ik_cond",
"label": "Ik [kA]"
},
{
"key": "Wm",
"label": "Wm [mm]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x35/16",
"cells": [
"Al",
"RM",
"0,22",
"15,3",
"0,868",
"3,4",
"153",
"145",
"3,3",
"2,1",
"345",
"23",
"563"
]
},
{
"configuration": "1x50/16",
"cells": [
"Al",
"RM",
"0,25",
"16,4",
"0,641",
"3,4",
"183",
"171",
"4,7",
"2,1",
"375",
"25",
"624"
]
},
{
"configuration": "1x70/16",
"cells": [
"Al",
"RM",
"0,28",
"17,9",
"0,443",
"3,4",
"228",
"208",
"6,6",
"2,1",
"390",
"26",
"707"
]
},
{
"configuration": "1x95/16",
"cells": [
"Al",
"RM",
"0,31",
"19,4",
"0,32",
"3,4",
"278",
"248",
"9",
"2,1",
"420",
"28",
"808"
]
},
{
"configuration": "1x120/16",
"cells": [
"Al",
"RM",
"0,34",
"20,9",
"0,253",
"3,4",
"321",
"283",
"11,3",
"2,1",
"435",
"29",
"905"
]
},
{
"configuration": "1x150/25",
"cells": [
"Al",
"RM",
"0,36",
"22,3",
"0,206",
"3,4",
"364",
"315",
"14,2",
"2,1",
"450",
"30",
"1085"
]
},
{
"configuration": "1x185/25",
"cells": [
"Al",
"RM",
"0,4",
"23,9",
"0,164",
"3,4",
"418",
"357",
"17,5",
"2,1",
"480",
"32",
"1226"
]
},
{
"configuration": "1x240/25",
"cells": [
"Al",
"RM",
"0,44",
"26,2",
"0,125",
"3,4",
"494",
"413",
"22,7",
"2,1",
"510",
"34",
"1423"
]
},
{
"configuration": "1x300/25",
"cells": [
"Al",
"RM",
"0,48",
"28,3",
"0,1",
"3,4",
"568",
"466",
"28,4",
"2,1",
"555",
"37",
"1666"
]
},
{
"configuration": "1x400/35",
"cells": [
"Al",
"RM",
"0,54",
"31,4",
"0,0778",
"3,4",
"660",
"529",
"37,8",
"2,1",
"600",
"40",
"2082"
]
},
{
"configuration": "1x500/35",
"cells": [
"Al",
"RM",
"0,61",
"34,6",
"0,0605",
"3,4",
"767",
"602",
"47,3",
"2,1",
"645",
"43",
"2447"
]
},
{
"configuration": "1x630/35",
"cells": [
"Al",
"RM",
"0,66",
"38",
"0,0469",
"3,4",
"855",
"685",
"59,6",
"2,1",
"690",
"46",
"2909"
]
},
{
"configuration": "1x800/35",
"cells": [
"Al",
"RM",
"0,76",
"42,3",
"0,0367",
"3,4",
"968",
"764",
"75,6",
"2,4",
"765",
"51",
"3520"
]
},
{
"configuration": "1x1000/35",
"cells": [
"Al",
"RM",
"0,84",
"46,2",
"0,0291",
"3,4",
"1187",
"852",
"94",
"2,4",
"855",
"57",
"4422"
]
}
]
},
{
"voltageLabel": "12/20 kV",
"metaItems": [
{
"label": "Spannung",
"value": "12/20 kV"
},
{
"label": "Prüfspannung",
"value": "42",
"unit": "kV"
},
{
"label": "Temperaturbereich",
"value": "-35-+90",
"unit": "°C"
},
{
"label": "Leitertemperatur (max.)",
"value": "+90",
"unit": "°C"
},
{
"label": "Kurzschlusstemperatur (max.)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimale Verlegetemperatur",
"value": "-20",
"unit": "°C"
},
{
"label": "Minimale Lagertemperatur",
"value": "-35",
"unit": "°C"
},
{
"label": "CPR-Klasse",
"value": "Fca",
"unit": ""
},
{
"label": "Flammhemmend",
"value": "no",
"unit": ""
}
],
"columns": [
{
"key": "Cond",
"label": "Leiter"
},
{
"key": "shape",
"label": "Form"
},
{
"key": "cap",
"label": "Cap [uF/km]"
},
{
"key": "DI",
"label": "DI [mm]"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Wi",
"label": "Wi [mm]"
},
{
"key": "Ibl",
"label": "Ibl [A]"
},
{
"key": "Ibe",
"label": "Ibe [A]"
},
{
"key": "Ik_cond",
"label": "Ik [kA]"
},
{
"key": "Wm",
"label": "Wm [mm]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x50/16",
"cells": [
"Al",
"RM",
"0,17",
"20,6",
"0,641",
"5,5",
"185",
"172",
"4,7",
"2,1",
"435",
"29",
"795"
]
},
{
"configuration": "1x70/16",
"cells": [
"Al",
"RM",
"0,19",
"22,1",
"0,443",
"5,5",
"231",
"210",
"6,6",
"2,1",
"465",
"31",
"888"
]
},
{
"configuration": "1x95/16",
"cells": [
"Al",
"RM",
"0,21",
"23,6",
"0,32",
"5,5",
"280",
"251",
"9",
"2,1",
"480",
"32",
"999"
]
},
{
"configuration": "1x120/16",
"cells": [
"Al",
"RM",
"0,23",
"25,1",
"0,253",
"5,5",
"323",
"285",
"11,3",
"2,1",
"510",
"34",
"1108"
]
},
{
"configuration": "1x150/25",
"cells": [
"Al",
"RM",
"0,25",
"26,5",
"0,206",
"5,5",
"366",
"319",
"14,2",
"2,1",
"525",
"35",
"1301"
]
},
{
"configuration": "1x185/25",
"cells": [
"Al",
"RM",
"0,27",
"28,1",
"0,164",
"5,5",
"420",
"361",
"17,5",
"2,1",
"555",
"37",
"1452"
]
},
{
"configuration": "1x240/25",
"cells": [
"Al",
"RM",
"0,3",
"30,4",
"0,125",
"5,5",
"496",
"417",
"22,7",
"2,1",
"585",
"39",
"1671"
]
},
{
"configuration": "1x300/25",
"cells": [
"Al",
"RM",
"0,32",
"32,5",
"0,1",
"5,5",
"569",
"471",
"28,4",
"2,1",
"615",
"41",
"1893"
]
},
{
"configuration": "1x400/35",
"cells": [
"Al",
"RM",
"0,36",
"35,6",
"0,078",
"5,5",
"660",
"535",
"37,8",
"2,1",
"660",
"44",
"2357"
]
},
{
"configuration": "1x500/35",
"cells": [
"Al",
"RM",
"0,4",
"38,8",
"0,061",
"5,5",
"766",
"609",
"47,3",
"2,1",
"705",
"47",
"2757"
]
},
{
"configuration": "1x630/35",
"cells": [
"Al",
"RM",
"0,44",
"42,2",
"0,047",
"5,5",
"861",
"690",
"59,6",
"2,4",
"765",
"51",
"3227"
]
},
{
"configuration": "1x800/35",
"cells": [
"Al",
"RM",
"0,49",
"46,5",
"0,037",
"5,5",
"976",
"764",
"75,6",
"2,4",
"840",
"56",
"3856"
]
},
{
"configuration": "1x1000/35",
"cells": [
"Al",
"RM",
"0,55",
"50,4",
"0,0291",
"5,5",
"1187",
"863",
"94",
"2,4",
"915",
"61",
"4824"
]
}
]
},
{
"voltageLabel": "18/30 kV",
"metaItems": [
{
"label": "Spannung",
"value": "18/30 kV"
},
{
"label": "Prüfspannung",
"value": "63",
"unit": "kV"
},
{
"label": "Temperaturbereich",
"value": "-35-+90",
"unit": "°C"
},
{
"label": "Leitertemperatur (max.)",
"value": "+90",
"unit": "°C"
},
{
"label": "Kurzschlusstemperatur (max.)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimale Verlegetemperatur",
"value": "-20",
"unit": "°C"
},
{
"label": "Minimale Lagertemperatur",
"value": "-35",
"unit": "°C"
},
{
"label": "CPR-Klasse",
"value": "Fca",
"unit": ""
},
{
"label": "Flammhemmend",
"value": "no",
"unit": ""
}
],
"columns": [
{
"key": "Cond",
"label": "Leiter"
},
{
"key": "shape",
"label": "Form"
},
{
"key": "cap",
"label": "Cap [uF/km]"
},
{
"key": "DI",
"label": "DI [mm]"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Wi",
"label": "Wi [mm]"
},
{
"key": "Ibl",
"label": "Ibl [A]"
},
{
"key": "Ibe",
"label": "Ibe [A]"
},
{
"key": "Ik_cond",
"label": "Ik [kA]"
},
{
"key": "Wm",
"label": "Wm [mm]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x50/16",
"cells": [
"Al",
"RM",
"0,13",
"25,6",
"0,641",
"8",
"187",
"174",
"4,7",
"2,1",
"510",
"34",
"1009"
]
},
{
"configuration": "1x70/16",
"cells": [
"Al",
"RM",
"0,15",
"27,1",
"0,443",
"8",
"232",
"213",
"6,6",
"2,1",
"540",
"36",
"1115"
]
},
{
"configuration": "1x95/16",
"cells": [
"Al",
"RM",
"0,16",
"28,6",
"0,32",
"8",
"282",
"254",
"9",
"2,1",
"555",
"37",
"1237"
]
},
{
"configuration": "1x120/16",
"cells": [
"Al",
"RM",
"0,17",
"30,1",
"0,253",
"8",
"325",
"289",
"11,3",
"2,1",
"585",
"39",
"1357"
]
},
{
"configuration": "1x150/25",
"cells": [
"Al",
"RM",
"0,19",
"31,5",
"0,206",
"8",
"367",
"322",
"14,2",
"2,1",
"600",
"40",
"1561"
]
},
{
"configuration": "1x185/25",
"cells": [
"Al",
"RM",
"0,2",
"33,1",
"0,164",
"8",
"421",
"364",
"17,5",
"2,1",
"630",
"42",
"1721"
]
},
{
"configuration": "1x240/25",
"cells": [
"Al",
"RM",
"0,22",
"35,4",
"0,125",
"8",
"496",
"422",
"22,7",
"2,1",
"660",
"44",
"1956"
]
},
{
"configuration": "1x300/25",
"cells": [
"Al",
"RM",
"0,24",
"37,5",
"0,1",
"8",
"568",
"476",
"28,4",
"2,1",
"690",
"46",
"2203"
]
},
{
"configuration": "1x400/35",
"cells": [
"Al",
"RM",
"0,26",
"40,6",
"0,078",
"8",
"659",
"541",
"37,8",
"2,1",
"735",
"49",
"2693"
]
},
{
"configuration": "1x500/35",
"cells": [
"Al",
"RM",
"0,29",
"43,8",
"0,061",
"8",
"764",
"616",
"47,3",
"2,4",
"795",
"53",
"3119"
]
},
{
"configuration": "1x630/35",
"cells": [
"Al",
"RM",
"0,32",
"47,2",
"0,047",
"8",
"861",
"690",
"59,6",
"2,4",
"840",
"56",
"3617"
]
},
{
"configuration": "1x800/35",
"cells": [
"Al",
"RM",
"0,36",
"51,5",
"0,037",
"8",
"984",
"770",
"75,6",
"2,4",
"915",
"61",
"4300"
]
},
{
"configuration": "1x1000/35",
"cells": [
"Al",
"RM",
"0,39",
"55,4",
"0,0291",
"8",
"1196",
"878",
"94",
"2,4",
"1005",
"67",
"5326"
]
}
]
}
]
}} />}>
<h3>Für raue Umgebungen und intensive Belastung</h3>
<p>Das <strong>NA2XS2Y</strong> erfüllt die Normen <strong>DIN VDE 0276-620</strong>, <strong>HD 620 S2</strong> und <strong>IEC 60502</strong> und ist speziell für die <strong>feste Verlegung in Innenräumen, Kabelkanälen, im Freien, in Erde und in Wasser</strong> ausgelegt. Es findet seinen Einsatz in <strong>Industrieanlagen, Schaltstationen und Kraftwerken</strong>, besonders dort, wo das Kabel beim Verlegen oder im Betrieb <strong>mechanisch stark beansprucht</strong> wird.</p>
<h3>Aufbau und technische Merkmale</h3>
<p>Das Kabel ist mit einem <strong>mehrdrähtigen Aluminiumleiter</strong> (Kl. 2 nach DIN VDE 0295 / IEC 60228) ausgestattet. Die <strong>VPE-Isolation</strong> (Typ DIX8) ist untrennbar mit der <strong>äußeren Leitschicht</strong> verbunden und sorgt gemeinsam mit der <strong>inneren Leitschicht</strong> für einen <strong>teilentladungsfreien Betrieb</strong>. Die <strong>Abschirmung</strong> erfolgt über eine Umspinnung aus Kupferdrähten mit Querleitwendeln. Der Außenmantel aus <strong>schwarzem PE (Typ DMP2)</strong> schützt vor Feuchtigkeit, mechanischem Druck und chemischen Einflüssen allerdings ohne Flammwidrigkeit.</p>
<h3>Besondere Eigenschaften und Einsatzvorteile</h3>
<p>NA2XS2Y ist <strong>erdverlegbar</strong> und für den Einsatz <strong>bei Temperaturen ab -20°C</strong> geeignet. Es ist <strong>silikon- und cadmiumfrei</strong>, frei von lackbenetzungsstörenden Stoffen und erreicht eine <strong>Betriebstemperatur von bis zu +90°C</strong>, im Kurzschlussfall sogar bis <strong>+250°C</strong>. Der schwarze PE-Mantel macht das Kabel zur <strong>ideal belastbaren Lösung für dauerhafte, unterirdische Mittelspannungsinstallationen</strong>.</p>
</ProductTabs>