Files
klz-cables.com/data/products/de/mittelspannungskabel/n2xsf2y.mdx
Marc Mintel f7aa880d9f
Some checks failed
Build & Deploy / 🔍 Prepare (push) Successful in 1m19s
Build & Deploy / 🧪 QA (push) Failing after 3m32s
Build & Deploy / 🚀 Deploy (push) Has been skipped
Build & Deploy / 🏗️ Build (push) Failing after 7m51s
Build & Deploy / ⚡ Lighthouse (push) Has been skipped
Build & Deploy / 🧪 Smoke Test (push) Has been skipped
Build & Deploy / ♿ WCAG (push) Has been skipped
Build & Deploy / 🛡️ Quality Gates (push) Has been skipped
Build & Deploy / 🔔 Notify (push) Successful in 10s
feat: migration von directus zu payloadcms
2026-02-24 19:25:43 +01:00

401 lines
9.4 KiB
Plaintext
Raw Blame History

This file contains invisible Unicode characters
This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
---
title: N2XS(F)2Y
sku: N2XS(F)2Y-medium-voltage-cables
description: >
Das N2XS(F)2Y Kabel ist ein längswasserdichtes Mittelspannungskabel mit
Kupferleiter, VPE-Isolation und widerstandsfähigem PE-Mantel. Es kombiniert
hohe elektrische Sicherheit mit robuster Außenschicht für anspruchsvolle
Anwendungen im Netzbetrieb.
categories:
- Mittelspannungskabel
images:
- /uploads/2025/01/N2XSF2Y-3-scaled.webp
application: >
Das N2XS(F)2Y erfüllt die gängigen Normen DIN VDE 0276-620, HD 620 S2 und IEC 60502 und
ist für die Verlegung in Innenräumen, Kabelkanälen, im Freien, in Wasser, Erde und auf
Kabelpritschen geeignet. Besonders in EVU-Netzen, Industrieanlagen und Kraftwerken
spielt dieses Kabel seine Stärken aus überall dort, wo Langlebigkeit,
Wasserdichtigkeit und Sicherheit gefragt sind.
locale: de
---
<ProductTabs technicalData={<ProductTechnicalData data={{
"technicalItems": [
{
"label": "CPR class",
"value": "Fca",
"unit": ""
},
{
"label": "Flame retardant",
"value": "no",
"unit": ""
},
{
"label": "Isolationsdicke (nom.) (mm)",
"value": "5,5",
"unit": "mm"
},
{
"label": "Manteldicke (min.) (mm)",
"value": "2,1",
"unit": "mm"
},
{
"label": "Maximal operating conductor temperature (°C)",
"value": "+90",
"unit": "°C"
},
{
"label": "Maximal short-circuit temperature (°C)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimal storage temperature (°C)",
"value": "-35",
"unit": "°C"
},
{
"label": "Minimal temperature for laying (°C)",
"value": "-20",
"unit": "°C"
},
{
"label": "Nennspannung (kV)",
"value": "12/20",
"unit": "kV"
},
{
"label": "Prüfspannung (kV)",
"value": "42",
"unit": "kV"
},
{
"label": "Shape of conductor",
"value": "RM",
"unit": ""
},
{
"label": "Temperaturbereich (°C)",
"value": "-35-+90",
"unit": "°C"
}
],
"voltageTables": [
{
"voltageLabel": "12/20 kV",
"metaItems": [
{
"label": "Spannung",
"value": "12/20 kV"
},
{
"label": "Prüfspannung",
"value": "42",
"unit": "kV"
},
{
"label": "Temperaturbereich",
"value": "-35-+90",
"unit": "°C"
},
{
"label": "Leitertemperatur (max.)",
"value": "+90",
"unit": "°C"
},
{
"label": "Kurzschlusstemperatur (max.)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimale Verlegetemperatur",
"value": "-20",
"unit": "°C"
},
{
"label": "Minimale Lagertemperatur",
"value": "-35",
"unit": "°C"
},
{
"label": "CPR-Klasse",
"value": "Fca",
"unit": ""
},
{
"label": "Flammhemmend",
"value": "no",
"unit": ""
}
],
"columns": [
{
"key": "Cond",
"label": "Leiter"
},
{
"key": "shape",
"label": "Form"
},
{
"key": "cap",
"label": "Cap [uF/km]"
},
{
"key": "DI",
"label": "DI [mm]"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Wi",
"label": "Wi [mm]"
},
{
"key": "Ibl",
"label": "Ibl [A]"
},
{
"key": "Ibe",
"label": "Ibe [A]"
},
{
"key": "Ik_cond",
"label": "Ik [kA]"
},
{
"key": "Wm",
"label": "Wm [mm]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x35/16",
"cells": [
"Cu",
"RM",
"0,16",
"19,5",
"0,524",
"5,5",
"200",
"189",
"5",
"2,1",
"420",
"28",
"949"
]
},
{
"configuration": "1x50/16",
"cells": [
"Cu",
"RM",
"0,17",
"20,5",
"0,387",
"5,5",
"239",
"222",
"7,1",
"2,1",
"435",
"29",
"1079"
]
},
{
"configuration": "1x70/16",
"cells": [
"Cu",
"RM",
"0,19",
"22,1",
"0,268",
"5,5",
"297",
"271",
"10",
"2,1",
"465",
"31",
"1315"
]
},
{
"configuration": "1x95/16",
"cells": [
"Cu",
"RM",
"0,21",
"23,6",
"0,193",
"5,5",
"361",
"323",
"13,6",
"2,1",
"480",
"32",
"1580"
]
},
{
"configuration": "1x120/16",
"cells": [
"Cu",
"RM",
"0,23",
"25,1",
"0,153",
"5,5",
"416",
"367",
"17,1",
"2,1",
"510",
"34",
"1862"
]
},
{
"configuration": "1x150/25",
"cells": [
"Cu",
"RM",
"0,25",
"26,5",
"0,124",
"5,5",
"470",
"409",
"21,4",
"2,1",
"525",
"35",
"2212"
]
},
{
"configuration": "1x185/25",
"cells": [
"Cu",
"RM",
"0,27",
"28,1",
"0,099",
"5,5",
"538",
"461",
"26,4",
"2,1",
"555",
"37",
"2585"
]
},
{
"configuration": "1x240/25",
"cells": [
"Cu",
"RM",
"0,3",
"30,6",
"0,075",
"5,5",
"634",
"532",
"34,3",
"2,1",
"585",
"39",
"3181"
]
},
{
"configuration": "1x300/25",
"cells": [
"Cu",
"RM",
"0,33",
"33",
"0,06",
"5,5",
"724",
"599",
"42,9",
"2,1",
"630",
"42",
"3851"
]
},
{
"configuration": "1x400/35",
"cells": [
"Cu",
"RM",
"0,36",
"35,6",
"0,047",
"5,5",
"829",
"671",
"57,2",
"2,1",
"660",
"44",
"4795"
]
},
{
"configuration": "1x500/35",
"cells": [
"Cu",
"RM",
"0,4",
"38,8",
"0,037",
"5,5",
"953",
"754",
"71,4",
"2,1",
"705",
"47",
"5873"
]
}
]
}
]
}} />}>
<h3>Entwickelt für leistungsstarke Netzumgebungen</h3>
<p>Das <strong>N2XS(F)2Y</strong> erfüllt die gängigen Normen <strong>DIN VDE 0276-620</strong>, <strong>HD 620 S2</strong> und <strong>IEC 60502</strong> und ist für die <strong>Verlegung in Innenräumen, Kabelkanälen, im Freien, in Wasser, Erde und auf Kabelpritschen</strong> geeignet. Besonders in <strong>EVU-Netzen, Industrieanlagen und Kraftwerken</strong> spielt dieses Kabel seine Stärken aus überall dort, wo Langlebigkeit, Wasserdichtigkeit und Sicherheit gefragt sind.</p>
<h3>Aufbau und technische Eigenschaften</h3>
<p>Im Inneren befindet sich ein <strong>blanker, mehrdrähtiger Kupferleiter</strong> (Klasse 2), umgeben von einer <strong>extrudierten VPE-Isolation mit innerer und haftender äußerer Leitschicht</strong>. Eine <strong>längswasserdichte, leitfähige Bandierung</strong>, eine <strong>Abschirmung aus Kupferdrähten mit Querleitwendeln</strong> und eine zusätzliche <strong>längswasserdichte Lage</strong> sichern den Aufbau. Der schwarze <strong>PE-Außenmantel (Typ DMP2)</strong> sorgt für hohe mechanische Belastbarkeit.</p>
<h3>Anwendungsbereiche und Vorteile</h3>
<p>Das N2XS(F)2Y ist <strong>erdverlegbar</strong>, <strong>resistent gegen aggressive Umwelteinflüsse</strong> und hält <strong>Temperaturen bis +90°C im Dauerbetrieb</strong> sowie <strong>+250°C im Kurzschlussfall</strong> stand. Es ist <strong>frei von silikon- und cadmiumhaltigen Stoffen</strong> und dank des <strong>teilentladungsfreien Aufbaus</strong> besonders geeignet für Netze mit höchsten Anforderungen an <strong>elektrische Betriebssicherheit</strong> und Langlebigkeit.</p>
</ProductTabs>