feat: Add new 1x1200/35 product configuration to data files and datasheets, including scripts to manage its technical and ampacity values.
2026-02-04 17:52:21 +01:00

1149 lines
24 KiB
Plaintext
Raw Blame History

This file contains invisible Unicode characters
This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
---
title: NA2XS(F)2Y
sku: NA2XS(F)2Y-medium-voltage-cables
description: >
Das NA2XS(F)2Y Kabel ist ein längswasserdichtes Mittelspannungskabel mit
Aluminiumleiter, VPE-Isolation und einem widerstandsfähigen PE-Mantel. Es
wurde für die energieeffiziente und sichere Verlegung in Erdreich und
kritischen Netzbereichen entwickelt.
categories:
- Mittelspannungskabel
images:
- /uploads/2025/01/NA2XSF2Y-3-scaled.webp
application: >
Das NA2XS(F)2Y entspricht den Normen DIN VDE 0276-620, HD 620 S2 und IEC 60502. Es
eignet sich für die Verlegung in Innenräumen, Kabelkanälen, im Erdreich, im Wasser, im
Freien oder auf Kabelpritschen. Der Einsatzschwerpunkt liegt in EVU-Netzen,
Industrieanlagen und Umspannwerken, wo zusätzliche Sicherheitsreserven gegen
eindringende Feuchtigkeit und mechanische Belastung erforderlich sind.
locale: de
---
<ProductTabs technicalData={<ProductTechnicalData data={{
"technicalItems": [
{
"label": "CPR class",
"value": "Fca",
"unit": ""
},
{
"label": "Flame retardant",
"value": "no",
"unit": ""
},
{
"label": "Maximal operating conductor temperature (°C)",
"value": "+90",
"unit": "°C"
},
{
"label": "Maximal short-circuit temperature (°C)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimal storage temperature (°C)",
"value": "-35",
"unit": "°C"
},
{
"label": "Minimal temperature for laying (°C)",
"value": "-20",
"unit": "°C"
},
{
"label": "Shape of conductor",
"value": "RM",
"unit": ""
},
{
"label": "Temperaturbereich (°C)",
"value": "-35-+90",
"unit": "°C"
}
],
"voltageTables": [
{
"voltageLabel": "6/10 kV",
"metaItems": [
{
"label": "Spannung",
"value": "6/10 kV"
},
{
"label": "Prüfspannung",
"value": "21",
"unit": "kV"
},
{
"label": "Temperaturbereich",
"value": "-35-+90",
"unit": "°C"
},
{
"label": "Leitertemperatur (max.)",
"value": "+90",
"unit": "°C"
},
{
"label": "Kurzschlusstemperatur (max.)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimale Verlegetemperatur",
"value": "-20",
"unit": "°C"
},
{
"label": "Minimale Lagertemperatur",
"value": "-35",
"unit": "°C"
},
{
"label": "CPR-Klasse",
"value": "Fca",
"unit": ""
},
{
"label": "Flammhemmend",
"value": "no",
"unit": ""
}
],
"columns": [
{
"key": "Cond",
"label": "Leiter"
},
{
"key": "shape",
"label": "Form"
},
{
"key": "cap",
"label": "Cap [uF/km]"
},
{
"key": "DI",
"label": "DI [mm]"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Wi",
"label": "Wi [mm]"
},
{
"key": "Ibl",
"label": "Ibl [A]"
},
{
"key": "Ibe",
"label": "Ibe [A]"
},
{
"key": "Ik_cond",
"label": "Ik [kA]"
},
{
"key": "Wm",
"label": "Wm [mm]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x50/16",
"cells": [
"Al",
"RM",
"0,24",
"16,4",
"0,641",
"3,4",
"183",
"171",
"4,7",
"2,1",
"375",
"25",
"625"
]
},
{
"configuration": "1x70/16",
"cells": [
"Al",
"RM",
"0,28",
"17,9",
"0,443",
"3,4",
"228",
"208",
"6,6",
"2,1",
"390",
"26",
"707"
]
},
{
"configuration": "1x95/16",
"cells": [
"Al",
"RM",
"0,31",
"19,4",
"0,32",
"3,4",
"278",
"248",
"9",
"2,1",
"420",
"28",
"808"
]
},
{
"configuration": "1x120/16",
"cells": [
"Al",
"RM",
"0,34",
"20,9",
"0,253",
"3,4",
"321",
"283",
"11,3",
"2,1",
"435",
"29",
"909"
]
},
{
"configuration": "1x150/25",
"cells": [
"Al",
"RM",
"0,36",
"22,3",
"0,206",
"3,4",
"364",
"315",
"14,2",
"2,1",
"450",
"30",
"1089"
]
},
{
"configuration": "1x185/25",
"cells": [
"Al",
"RM",
"0,4",
"23,9",
"0,164",
"3,4",
"418",
"357",
"17,5",
"2,1",
"480",
"32",
"1232"
]
},
{
"configuration": "1x240/25",
"cells": [
"Al",
"RM",
"0,44",
"26,2",
"0,125",
"3,4",
"494",
"413",
"22,7",
"2,1",
"510",
"34",
"1427"
]
},
{
"configuration": "1x300/25",
"cells": [
"Al",
"RM",
"0,48",
"28,3",
"0,1",
"3,4",
"568",
"466",
"28,4",
"2,1",
"555",
"37",
"1666"
]
},
{
"configuration": "1x400/35",
"cells": [
"Al",
"RM",
"0,54",
"31,4",
"0,0778",
"3,4",
"660",
"529",
"37,8",
"2,1",
"600",
"40",
"2089"
]
},
{
"configuration": "1x500/35",
"cells": [
"Al",
"RM",
"0,61",
"34,6",
"0,0605",
"3,4",
"767",
"602",
"47,3",
"2,1",
"645",
"43",
"2456"
]
},
{
"configuration": "1x630/35",
"cells": [
"Al",
"RM",
"0,67",
"38",
"0,0469",
"3,4",
"855",
"688",
"59,6",
"2,1",
"690",
"46",
"2909"
]
},
{
"configuration": "1x800/35",
"cells": [
"Al",
"RM",
"0,76",
"42,3",
"0,0367",
"3,4",
"968",
"764",
"75,6",
"2,4",
"765",
"51",
"3521"
]
},
{
"configuration": "1x1000/35",
"cells": [
"Al",
"RM",
"0,84",
"46,2",
"0,0291",
"3,4",
"1187",
"852",
"94",
"2,4",
"825",
"55",
"4195"
]
},
{
"configuration": "1x1200/35",
"cells": [
"Al",
"RM",
"0,95",
"48,5",
"0,0247",
"3,4",
"Auf Anfrage",
"Auf Anfrage",
"113",
"2,4",
"885",
"59",
"4800"
]
}
]
},
{
"voltageLabel": "12/20 kV",
"metaItems": [
{
"label": "Spannung",
"value": "12/20 kV"
},
{
"label": "Prüfspannung",
"value": "42",
"unit": "kV"
},
{
"label": "Temperaturbereich",
"value": "-35-+90",
"unit": "°C"
},
{
"label": "Leitertemperatur (max.)",
"value": "+90",
"unit": "°C"
},
{
"label": "Kurzschlusstemperatur (max.)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimale Verlegetemperatur",
"value": "-20",
"unit": "°C"
},
{
"label": "Minimale Lagertemperatur",
"value": "-35",
"unit": "°C"
},
{
"label": "CPR-Klasse",
"value": "Fca",
"unit": ""
},
{
"label": "Flammhemmend",
"value": "no",
"unit": ""
}
],
"columns": [
{
"key": "Cond",
"label": "Leiter"
},
{
"key": "shape",
"label": "Form"
},
{
"key": "cap",
"label": "Cap [uF/km]"
},
{
"key": "DI",
"label": "DI [mm]"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Wi",
"label": "Wi [mm]"
},
{
"key": "Ibl",
"label": "Ibl [A]"
},
{
"key": "Ibe",
"label": "Ibe [A]"
},
{
"key": "Ik_cond",
"label": "Ik [kA]"
},
{
"key": "Wm",
"label": "Wm [mm]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x50/16",
"cells": [
"Al",
"RM",
"0,17",
"20,5",
"0,641",
"5,5",
"185",
"172",
"4,7",
"2,1",
"435",
"29",
"780"
]
},
{
"configuration": "1x70/16",
"cells": [
"Al",
"RM",
"0,19",
"22",
"0,443",
"5,5",
"231",
"210",
"6,6",
"2,1",
"450",
"30",
"873"
]
},
{
"configuration": "1x95/16",
"cells": [
"Al",
"RM",
"0,21",
"23,5",
"0,32",
"5,5",
"280",
"251",
"9",
"2,1",
"480",
"32",
"984"
]
},
{
"configuration": "1x120/16",
"cells": [
"Al",
"RM",
"0,23",
"25",
"0,253",
"5,5",
"323",
"285",
"11,3",
"2,1",
"495",
"33",
"1093"
]
},
{
"configuration": "1x150/25",
"cells": [
"Al",
"RM",
"0,25",
"26,4",
"0,206",
"5,5",
"366",
"319",
"14,2",
"2,1",
"525",
"35",
"1282"
]
},
{
"configuration": "1x185/25",
"cells": [
"Al",
"RM",
"0,27",
"28",
"0,164",
"5,5",
"420",
"361",
"17,5",
"2,1",
"540",
"36",
"1434"
]
},
{
"configuration": "1x240/25",
"cells": [
"Al",
"RM",
"0,3",
"30,3",
"0,125",
"5,5",
"496",
"417",
"22,7",
"2,1",
"585",
"39",
"1647"
]
},
{
"configuration": "1x300/25",
"cells": [
"Al",
"RM",
"0,32",
"32,4",
"0,1",
"5,5",
"569",
"471",
"28,4",
"2,1",
"615",
"41",
"1869"
]
},
{
"configuration": "1x400/35",
"cells": [
"Al",
"RM",
"0,36",
"35,5",
"0,0778",
"5,5",
"660",
"535",
"37,8",
"2,1",
"660",
"44",
"2321"
]
},
{
"configuration": "1x500/35",
"cells": [
"Al",
"RM",
"0,4",
"38,7",
"0,0605",
"5,5",
"766",
"609",
"47,3",
"2,1",
"705",
"47",
"2728"
]
},
{
"configuration": "1x630/35",
"cells": [
"Al",
"RM",
"0,44",
"42,1",
"0,0469",
"5,5",
"861",
"690",
"59,6",
"2,4",
"765",
"51",
"3227"
]
},
{
"configuration": "1x800/35",
"cells": [
"Al",
"RM",
"0,49",
"46,4",
"0,0367",
"5,5",
"976",
"764",
"75,6",
"2,4",
"825",
"55",
"3846"
]
},
{
"configuration": "1x1000/35",
"cells": [
"Al",
"RM",
"0,54",
"50,3",
"0,0291",
"5,5",
"1095",
"837",
"94,6",
"2,4",
"900",
"60",
"4634"
]
},
{
"configuration": "1x1200/35",
"cells": [
"Al",
"RM",
"1,05",
"52,3",
"0,0247",
"5,5",
"Auf Anfrage",
"Auf Anfrage",
"113",
"2,4",
"990",
"66",
"5200"
]
}
]
},
{
"voltageLabel": "18/30 kV",
"metaItems": [
{
"label": "Spannung",
"value": "18/30 kV"
},
{
"label": "Prüfspannung",
"value": "63",
"unit": "kV"
},
{
"label": "Temperaturbereich",
"value": "-35-+90",
"unit": "°C"
},
{
"label": "Leitertemperatur (max.)",
"value": "+90",
"unit": "°C"
},
{
"label": "Kurzschlusstemperatur (max.)",
"value": "+250",
"unit": "°C"
},
{
"label": "Minimale Verlegetemperatur",
"value": "-20",
"unit": "°C"
},
{
"label": "Minimale Lagertemperatur",
"value": "-35",
"unit": "°C"
},
{
"label": "CPR-Klasse",
"value": "Fca",
"unit": ""
},
{
"label": "Flammhemmend",
"value": "no",
"unit": ""
}
],
"columns": [
{
"key": "Cond",
"label": "Leiter"
},
{
"key": "shape",
"label": "Form"
},
{
"key": "cap",
"label": "Cap [uF/km]"
},
{
"key": "DI",
"label": "DI [mm]"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Wi",
"label": "Wi [mm]"
},
{
"key": "Ibl",
"label": "Ibl [A]"
},
{
"key": "Ibe",
"label": "Ibe [A]"
},
{
"key": "Ik_cond",
"label": "Ik [kA]"
},
{
"key": "Wm",
"label": "Wm [mm]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x50/16",
"cells": [
"Al",
"RM",
"0,13",
"25,5",
"0,641",
"8",
"187",
"174",
"4,7",
"2,1",
"510",
"34",
"988"
]
},
{
"configuration": "1x70/16",
"cells": [
"Al",
"RM",
"0,15",
"27",
"0,443",
"8",
"232",
"213",
"6,6",
"2,1",
"525",
"35",
"1094"
]
},
{
"configuration": "1x95/16",
"cells": [
"Al",
"RM",
"0,16",
"28,5",
"0,32",
"8",
"282",
"254",
"9",
"2,1",
"555",
"37",
"1216"
]
},
{
"configuration": "1x120/16",
"cells": [
"Al",
"RM",
"0,17",
"30",
"0,253",
"8",
"325",
"289",
"11,3",
"2,1",
"570",
"38",
"1335"
]
},
{
"configuration": "1x150/25",
"cells": [
"Al",
"RM",
"0,19",
"31,4",
"0,206",
"8",
"367",
"322",
"14,2",
"2,1",
"600",
"40",
"1535"
]
},
{
"configuration": "1x185/25",
"cells": [
"Al",
"RM",
"0,2",
"33",
"0,164",
"8",
"421",
"364",
"17,5",
"2,1",
"615",
"41",
"1699"
]
},
{
"configuration": "1x240/25",
"cells": [
"Al",
"RM",
"0,22",
"35,3",
"0,125",
"8",
"496",
"422",
"22,7",
"2,1",
"660",
"44",
"1928"
]
},
{
"configuration": "1x300/25",
"cells": [
"Al",
"RM",
"0,24",
"37,4",
"0,1",
"8",
"568",
"476",
"28,4",
"2,1",
"690",
"46",
"2167"
]
},
{
"configuration": "1x400/35",
"cells": [
"Al",
"RM",
"0,26",
"40,5",
"0,0778",
"8",
"659",
"541",
"37,8",
"2,1",
"735",
"49",
"2654"
]
},
{
"configuration": "1x500/35",
"cells": [
"Al",
"RM",
"0,29",
"43,7",
"0,0605",
"8",
"764",
"616",
"47,3",
"2,4",
"780",
"52",
"3087"
]
},
{
"configuration": "1x630/35",
"cells": [
"Al",
"RM",
"0,32",
"47,1",
"0,0469",
"8",
"866",
"692",
"59,6",
"2,4",
"840",
"56",
"3603"
]
},
{
"configuration": "1x800/35",
"cells": [
"Al",
"RM",
"0,36",
"51,4",
"0,0367",
"8",
"984",
"770",
"75,6",
"2,4",
"900",
"60",
"4284"
]
},
{
"configuration": "1x1000/35",
"cells": [
"Al",
"RM",
"0,39",
"55,3",
"0,0291",
"8",
"1095",
"841",
"94,6",
"2,4",
"975",
"65",
"5093"
]
},
{
"configuration": "1x1200/35",
"cells": [
"Al",
"RM",
"1,15",
"57,5",
"0,0247",
"8,0",
"Auf Anfrage",
"Auf Anfrage",
"113",
"2,4",
"1065",
"71",
"5900"
]
}
]
}
]
}} />}>
<section>
<h3 data-start="508" data-end="575">Für leistungsstarke Versorgungsnetze mit erhöhtem Schutzbedarf</h3>
<p data-start="577" data-end="994">Das <strong data-start="581" data-end="595">NA2XS(F)2Y</strong> entspricht den Normen <strong data-start="618" data-end="638">DIN VDE 0276-620</strong>, <strong data-start="640" data-end="653">HD 620 S2</strong> und <strong data-start="658" data-end="671">IEC 60502</strong>. Es eignet sich für die <strong data-start="696" data-end="797">Verlegung in Innenräumen, Kabelkanälen, im Erdreich, im Wasser, im Freien oder auf Kabelpritschen</strong>. Der Einsatzschwerpunkt liegt in <strong data-start="831" data-end="881">EVU-Netzen, Industrieanlagen und Umspannwerken</strong>, wo zusätzliche Sicherheitsreserven gegen eindringende Feuchtigkeit und mechanische Belastung erforderlich sind.</p>
<h3 data-start="996" data-end="1033">Aufbau und Materialeigenschaften</h3>
<p data-start="1035" data-end="1537">Der Leiter besteht aus <strong data-start="1058" data-end="1085">mehrdrähtigem Aluminium</strong> (Klasse 2), umgeben von einer <strong data-start="1116" data-end="1139">inneren Leitschicht</strong> und einer <strong data-start="1150" data-end="1168">VPE-Isolierung</strong> mit festhaftender äußerer Leitschicht extrudiert in einem Arbeitsgang für maximale Betriebssicherheit. Die Abschirmung erfolgt durch eine <strong data-start="1309" data-end="1354">Kupferdraht-Umspinnung mit Querleitwendel</strong>, ergänzt durch eine <strong data-start="1375" data-end="1407">längswasserdichte Bandierung</strong>. Der Außenmantel besteht aus <strong data-start="1437" data-end="1464">schwarzem PE (Typ DMP2)</strong> und schützt zuverlässig vor mechanischer Beanspruchung und Feuchtigkeit.</p>
<h3 data-start="1539" data-end="1577">Eigenschaften und Einsatzbereiche</h3>
<p data-start="1579" data-end="1977">Das NA2XS(F)2Y ist <strong data-start="1598" data-end="1614">erdverlegbar</strong>, <strong data-start="1616" data-end="1644">silikon- und cadmiumfrei</strong> sowie <strong data-start="1651" data-end="1704">resistent gegen lackbenetzungsstörende Substanzen</strong>. Es hält <strong data-start="1714" data-end="1746">Dauertemperaturen bis +90°C</strong> stand und übersteht <strong data-start="1767" data-end="1805">Kurzschlussbelastungen bis +250°C</strong>. Dank seines durchdachten, teilentladungsfreien Aufbaus ist es besonders gut geeignet für die <strong data-start="1900" data-end="1976">sichere Energieverteilung in feuchten, komplexen Installationsumgebungen</strong>.</p>
</section>
</ProductTabs>