Files
klz-cables.com/data/products/de/niederspannungskabel/na2x2y.mdx
Marc Mintel d11dae5f85
Some checks failed
Build & Deploy / 🔍 Prepare (push) Successful in 7s
Build & Deploy / 🧪 QA (push) Failing after 2m14s
Build & Deploy / 🏗️ Build (push) Has been skipped
Build & Deploy / 🚀 Deploy (push) Has been skipped
Build & Deploy / 🧪 Smoke Test (push) Has been skipped
Build & Deploy / ⚡ Lighthouse (push) Has been skipped
Build & Deploy / ♿ WCAG (push) Has been skipped
Build & Deploy / 📸 Visual Diff (push) Has been skipped
Build & Deploy / 🛡️ Quality Gates (push) Has been skipped
Build & Deploy / 🔔 Notify (push) Successful in 2s
chore: achieve 100/100 pagespeed and html validation
- fix html validation errors in blog mdx (empty headings)
- fix backstopjs esm compatibility and missing reference images
- optimize product data structure and next.config.mjs
- finalize accessibility and seo improvements
2026-02-22 02:02:38 +01:00

810 lines
17 KiB
Plaintext
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
---
title: NA2X2Y
sku: NA2X2Y-low-voltage-cables
description: >
Das NA2X2Y Kabel ist ein strapazierfähiges Niederspannungskabel mit
Aluminiumleiter, PE-Isolation und HDPE-Mantel. Es wurde für feste Verlegungen
unter erhöhter mechanischer Beanspruchung entwickelt und eignet sich besonders
für anspruchsvolle industrielle und energietechnische Infrastrukturen.
categories:
- Niederspannungskabel
images:
- /uploads/2025/01/NA2X2Y-scaled.webp
application: >
Das NA2X2Y entspricht der Norm DIN VDE 0276-603 (HD 603) und ist ausgelegt für die
feste Verlegung in Innenräumen, Kabelkanälen, im Erdreich, im Wasser oder im Freien.
Es kommt bevorzugt in Kraftwerken, Industrieanlagen, Schaltanlagen und Ortsnetzen zum
Einsatz überall dort, wo robuste Kabel gefragt sind, die im Betrieb und bei der
Verlegung hohen mechanischen Belastungen standhalten.
locale: de
---
<ProductTabs technicalData={<ProductTechnicalData data={{
"technicalItems": [
{
"label": "Biegeradius (mm)",
"value": "15/12xD",
"unit": "mm"
},
{
"label": "CPR class",
"value": "Fca",
"unit": ""
},
{
"label": "Maximal operating conductor temperature (°C)",
"value": "90",
"unit": "°C"
},
{
"label": "Maximal short-circuit temperature (°C)",
"value": "250",
"unit": "°C"
},
{
"label": "Minimal storage temperature (°C)",
"value": "-35",
"unit": "°C"
},
{
"label": "Minimal temperature for laying (°C)",
"value": "-20",
"unit": "°C"
},
{
"label": "Nennspannung (kV)",
"value": "0.6/1",
"unit": "kV"
},
{
"label": "Prüfspannung (kV)",
"value": "4",
"unit": "kV"
},
{
"label": "Self-extinguishing of single cable",
"value": "no",
"unit": ""
},
{
"label": "Temperaturbereich (°C)",
"value": "-35-+90",
"unit": "°C"
}
],
"voltageTables": [
{
"voltageLabel": "0.6/1 kV",
"metaItems": [
{
"label": "Spannung",
"value": "0.6/1 kV"
},
{
"label": "Prüfspannung",
"value": "4",
"unit": "kV"
},
{
"label": "Temperaturbereich",
"value": "-35-+90",
"unit": "°C"
},
{
"label": "Leitertemperatur (max.)",
"value": "90",
"unit": "°C"
},
{
"label": "Kurzschlusstemperatur (max.)",
"value": "250",
"unit": "°C"
},
{
"label": "Minimale Verlegetemperatur",
"value": "-20",
"unit": "°C"
},
{
"label": "Minimale Lagertemperatur",
"value": "-35",
"unit": "°C"
},
{
"label": "CPR-Klasse",
"value": "Fca",
"unit": ""
},
{
"label": "Flammhemmend",
"value": "no",
"unit": ""
}
],
"columns": [
{
"key": "Cond",
"label": "Leiter"
},
{
"key": "shape",
"label": "Form"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Wi",
"label": "Wi [mm]"
},
{
"key": "Wm",
"label": "Wm [mm]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x16",
"cells": [
"Al",
"RE",
"1,91",
"0,7",
"1,8",
"12xD",
"10",
"104"
]
},
{
"configuration": "1x25",
"cells": [
"Al",
"RE",
"1,2",
"0,9",
"1,8",
"12xD",
"12",
"144"
]
},
{
"configuration": "1x35",
"cells": [
"Al",
"RE",
"0,868",
"0,9",
"1,8",
"12xD",
"13",
"179"
]
},
{
"configuration": "1x50",
"cells": [
"Al",
"RMV",
"0,641",
"1",
"1,8",
"12xD",
"14",
"232"
]
},
{
"configuration": "1x70",
"cells": [
"Al",
"RMV",
"0,443",
"1,1",
"1,8",
"12xD",
"16",
"309"
]
},
{
"configuration": "1x95",
"cells": [
"Al",
"RMV",
"0,32",
"1,1",
"1,8",
"12xD",
"18",
"394"
]
},
{
"configuration": "1x120",
"cells": [
"Al",
"RMV",
"0,253",
"1,2",
"1,8",
"12xD",
"20",
"479"
]
},
{
"configuration": "1x150",
"cells": [
"Al",
"RMV",
"0,206",
"1,4",
"1,8",
"12xD",
"22",
"587"
]
},
{
"configuration": "1x185",
"cells": [
"Al",
"RMV",
"0,164",
"1,6",
"1,8",
"12xD",
"24",
"722"
]
},
{
"configuration": "1x240",
"cells": [
"Al",
"RMV",
"0,125",
"1,7",
"1,8",
"12xD",
"26",
"908"
]
},
{
"configuration": "1x300",
"cells": [
"Al",
"RMV",
"0,1",
"1,8",
"1,8",
"12xD",
"29",
"1102"
]
},
{
"configuration": "1x400",
"cells": [
"Al",
"RMV",
"0,0078",
"2",
"1,9",
"12xD",
"32",
"1398"
]
},
{
"configuration": "1x500",
"cells": [
"Al",
"RMV",
"0,065",
"2,2",
"2",
"12xD",
"36",
"1763"
]
},
{
"configuration": "3x16",
"cells": [
"Al",
"RE",
"1,91",
"0,7",
"1,8",
"12xD",
"19",
"454"
]
},
{
"configuration": "3x25",
"cells": [
"Al",
"RE",
"1,2",
"0,9",
"1,8",
"12xD",
"22",
"634"
]
},
{
"configuration": "3x35",
"cells": [
"Al",
"RE",
"0,868",
"0,9",
"1,8",
"12xD",
"25",
"788"
]
},
{
"configuration": "3x50",
"cells": [
"Al",
"SM",
"0,641",
"1",
"1,8",
"12xD",
"26",
"870"
]
},
{
"configuration": "3x70",
"cells": [
"Al",
"SM",
"0,443",
"1,1",
"1,9",
"12xD",
"30",
"1170"
]
},
{
"configuration": "3x95",
"cells": [
"Al",
"SM",
"0,32",
"1,1",
"2",
"12xD",
"33",
"1463"
]
},
{
"configuration": "3x120",
"cells": [
"Al",
"SM",
"0,253",
"1,2",
"2,1",
"12xD",
"39",
"1802"
]
},
{
"configuration": "3x150",
"cells": [
"Al",
"SM",
"0,206",
"1,4",
"2,3",
"12xD",
"41",
"2184"
]
},
{
"configuration": "3x185",
"cells": [
"Al",
"SM",
"0,164",
"1,6",
"2,4",
"12xD",
"45",
"2647"
]
},
{
"configuration": "3x240",
"cells": [
"Al",
"SM",
"0,125",
"1,7",
"2,6",
"12xD",
"51",
"3362"
]
},
{
"configuration": "3x35+16",
"cells": [
"Al",
"RE",
"0,868",
"0.9/0.7",
"1,8",
"12xD",
"25",
"855"
]
},
{
"configuration": "3x70+35",
"cells": [
"Al",
"SM",
"0,268",
"1.1/0.9",
"1,9",
"12xD",
"32",
"2828"
]
},
{
"configuration": "3x95+50",
"cells": [
"Al",
"SM",
"0,193",
"1.1/1.0",
"2,1",
"12xD",
"37",
"3757"
]
},
{
"configuration": "3x120+70",
"cells": [
"Al",
"SM",
"0,153",
"1.2/1.1",
"2,2",
"12xD",
"40",
"4707"
]
},
{
"configuration": "3x150+70",
"cells": [
"Al",
"SM",
"0,124",
"1.4/1.1",
"2,3",
"12xD",
"45",
"5675"
]
},
{
"configuration": "3x185+95",
"cells": [
"Al",
"SM",
"0,0991",
"1.6/1.1",
"2,5",
"12xD",
"49",
"7071"
]
},
{
"configuration": "3x240+120",
"cells": [
"Al",
"SM",
"0,0754",
"1.7/1.2",
"2,7",
"12xD",
"56",
"9138"
]
},
{
"configuration": "4x10",
"cells": [
"Al",
"RE",
"1,83",
"0,7",
"1,8",
"12xD",
"18",
"642"
]
},
{
"configuration": "4x16",
"cells": [
"Al",
"RE",
"1,15",
"0,7",
"1,8",
"12xD",
"21",
"910"
]
},
{
"configuration": "4x25",
"cells": [
"Al",
"RMV",
"0,727",
"0,9",
"1,8",
"12xD",
"25",
"1391"
]
},
{
"configuration": "4x35",
"cells": [
"Al",
"RMV",
"0,524",
"0,9",
"1,8",
"12xD",
"28",
"1834"
]
},
{
"configuration": "4x50",
"cells": [
"Al",
"SM",
"0,387",
"1",
"1,9",
"12xD",
"29",
"2255"
]
},
{
"configuration": "4x70",
"cells": [
"Al",
"SM",
"0,268",
"1,1",
"2",
"12xD",
"33",
"3158"
]
},
{
"configuration": "4x95",
"cells": [
"Al",
"SM",
"0,193",
"1,1",
"2,1",
"12xD",
"37",
"4200"
]
},
{
"configuration": "4x120",
"cells": [
"Al",
"SM",
"0,153",
"1,2",
"2,3",
"12xD",
"41",
"5259"
]
},
{
"configuration": "4x150",
"cells": [
"Al",
"SM",
"0,124",
"1,4",
"2,4",
"12xD",
"46",
"6439"
]
},
{
"configuration": "4x185",
"cells": [
"Al",
"SM",
"0,0991",
"1,6",
"2,6",
"12xD",
"51",
"7967"
]
},
{
"configuration": "4x240",
"cells": [
"Al",
"SM",
"0,0754",
"1,7",
"2,8",
"12xD",
"57",
"10324"
]
},
{
"configuration": "5x10",
"cells": [
"Al",
"RE",
"1,83",
"0,7",
"1,8",
"12xD",
"20",
"767"
]
},
{
"configuration": "5x16",
"cells": [
"Al",
"RE",
"1,15",
"0,7",
"1,8",
"12xD",
"22",
"1100"
]
},
{
"configuration": "5x25",
"cells": [
"Al",
"RMV",
"0,727",
"0,9",
"1,8",
"12xD",
"27",
"1676"
]
},
{
"configuration": "5x35",
"cells": [
"Al",
"RMV",
"0,524",
"0,9",
"1,8",
"12xD",
"31",
"2266"
]
},
{
"configuration": "5x50",
"cells": [
"Al",
"SM",
"0,387",
"1",
"2",
"12xD",
"33",
"2877"
]
},
{
"configuration": "5x70",
"cells": [
"Al",
"SM",
"0,268",
"1,1",
"2,1",
"12xD",
"38",
"3979"
]
},
{
"configuration": "5x95",
"cells": [
"Al",
"SM",
"0,193",
"1,1",
"2,3",
"12xD",
"42",
"5342"
]
},
{
"configuration": "5x120",
"cells": [
"Al",
"SM",
"0,153",
"1,2",
"2,4",
"12xD",
"47",
"6625"
]
}
]
}
]
}} />}>
<section>
<h3 data-start="488" data-end="537">Optimal für mechanisch belastete Anwendungen</h3>
<p data-start="539" data-end="948">Das <strong data-start="543" data-end="553">NA2X2Y</strong> entspricht der Norm <strong data-start="574" data-end="603">DIN VDE 0276-603 (HD 603)</strong> und ist ausgelegt für die <strong data-start="630" data-end="717">feste Verlegung in Innenräumen, Kabelkanälen, im Erdreich, im Wasser oder im Freien</strong>. Es kommt bevorzugt in <strong data-start="741" data-end="789">Kraftwerken, Industrieanlagen, Schaltanlagen</strong> und <strong data-start="794" data-end="808">Ortsnetzen</strong> zum Einsatz überall dort, wo robuste Kabel gefragt sind, die im Betrieb und bei der Verlegung hohen mechanischen Belastungen standhalten.</p>
<h3 data-start="950" data-end="979">Aufbau und Eigenschaften</h3>
<p data-start="981" data-end="1427">Der elektrische Leiter besteht aus <strong data-start="1016" data-end="1029">Aluminium</strong>, wahlweise als rund eindrähtig (RE), rund mehrdrähtig (RM) oder sektorförmig (SE/SM). Die Adern sind mit <strong data-start="1135" data-end="1150">PE isoliert</strong>, verseilt und durch eine <strong data-start="1176" data-end="1209">gemeinsame EPDM-Aderumhüllung</strong> geschützt. Der Außenmantel besteht aus <strong data-start="1249" data-end="1257">HDPE</strong>, ist schwarz, UV-beständig und besonders widerstandsfähig gegenüber Abrieb, Druck und Feuchtigkeit ideal für langfristige Installationen in anspruchsvollen Umgebungen.</p>
<h3 data-start="1429" data-end="1449">Einsatzvorteile</h3>
<p data-start="1451" data-end="1756">NA2X2Y Kabel bieten eine <strong data-start="1476" data-end="1524">technisch robuste und wirtschaftliche Lösung</strong> für die Energieverteilung in Netzen mit erhöhten Anforderungen. Ihre hohe mechanische Belastbarkeit und Witterungsbeständigkeit machen sie zur ersten Wahl für anspruchsvolle Infrastrukturanwendungen im Energie- und Industriesektor.</p>
</section>
</ProductTabs>