chore: achieve 100/100 pagespeed and html validation
Build & Deploy / 🔍 Prepare (push) Successful in 7s
Build & Deploy / 🧪 QA (push) Failing after 2m14s
Build & Deploy / 🏗️ Build (push) Has been skipped
Build & Deploy / 🚀 Deploy (push) Has been skipped
Build & Deploy / 🧪 Smoke Test (push) Has been skipped
Build & Deploy / ⚡ Lighthouse (push) Has been skipped
Build & Deploy / ♿ WCAG (push) Has been skipped
Build & Deploy / 📸 Visual Diff (push) Has been skipped
Build & Deploy / 🛡️ Quality Gates (push) Has been skipped
Build & Deploy / 🔔 Notify (push) Successful in 2s

- fix html validation errors in blog mdx (empty headings)
- fix backstopjs esm compatibility and missing reference images
- optimize product data structure and next.config.mjs
- finalize accessibility and seo improvements
This commit is contained in:
2026-02-22 02:02:38 +01:00
parent dd7e800ec4
commit d11dae5f85
63 changed files with 64 additions and 24 deletions
+248
View File
@@ -0,0 +1,248 @@
---
title: H1Z2Z2-K
sku: H1Z2Z2-K-solar-cables
description: >
The H1Z2Z2-K cable is a highly flexible, halogen-free solar cable for modern
photovoltaic systems. It meets the highest standards for safety, weather
resistance, and electrical performance – for both indoor and outdoor use.
categories:
- Solar Cables
images:
- /uploads/2025/06/H1Z2Z2-K-scaled.webp
application: >
The H1Z2Z2-K complies with DIN EN 50618 (VDE 0283-618) and is specifically designed for
the cabling of photovoltaic systems. It can be installed permanently or used flexibly –
indoors, outdoors, in industrial facilities, agricultural operations, or even in
hazardous (explosive) areas. The cable is UV-, ozone- and water-resistant (AD7) and
can be laid directly in the ground.
locale: en
---
<ProductTabs technicalData={<ProductTechnicalData data={{
"technicalItems": [
{
"label": "Maximal operating conductor temperature (°C)",
"value": "120",
"unit": "°C"
},
{
"label": "Maximal short-circuit temperature (°C)",
"value": "+250 Max. 5 sec.",
"unit": "°C"
},
{
"label": "Minimal temperature for laying (°C)",
"value": "-25",
"unit": "°C"
},
{
"label": "Operating temperature range (°C)",
"value": "-40/+90",
"unit": "°C"
},
{
"label": "Rated voltage (kV)",
"value": "AC: 1000/1000 V DC: 1500 V",
"unit": "kV"
},
{
"label": "Shape of conductor",
"value": "RM",
"unit": ""
},
{
"label": "Test voltage (kV)",
"value": "6,5 AC, 15 DC (5 min.)",
"unit": "kV"
}
],
"voltageTables": [
{
"voltageLabel": "AC: 1000 / 1000 V DC: 1500 V",
"metaItems": [
{
"label": "Voltage",
"value": "AC: 1000 / 1000 V DC: 1500 V"
},
{
"label": "Test voltage",
"value": "6,5 AC, 15 DC (5 min.)",
"unit": "kV"
},
{
"label": "Operating temperature range",
"value": "-40/+90",
"unit": "°C"
},
{
"label": "Conductor temperature (max.)",
"value": "120",
"unit": "°C"
},
{
"label": "Short-circuit temperature (max.)",
"value": "+250 Max. 5 sec.",
"unit": "°C"
},
{
"label": "Minimum laying temperature",
"value": "-25",
"unit": "°C"
}
],
"columns": [
{
"key": "Cond",
"label": "Cond."
},
{
"key": "shape",
"label": "Shape"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x1,5",
"cells": [
"",
"RM",
"13.7",
"22",
"4.5",
"33"
]
},
{
"configuration": "1x2,5",
"cells": [
"",
"RM",
"8.21",
"24",
"4.9",
"41"
]
},
{
"configuration": "1x4",
"cells": [
"",
"RM",
"5.09",
"26",
"5.5",
"57"
]
},
{
"configuration": "1x6",
"cells": [
"",
"RM",
"3.39",
"30",
"5.9",
"73"
]
},
{
"configuration": "1x10",
"cells": [
"",
"RM",
"1.95",
"35",
"6.9",
"110"
]
},
{
"configuration": "1x16",
"cells": [
"",
"RM",
"1.24",
"40",
"8",
"170"
]
},
{
"configuration": "1x25",
"cells": [
"",
"RM",
"0.795",
"50",
"10",
"260"
]
},
{
"configuration": "1x35",
"cells": [
"",
"RM",
"0.565",
"56",
"11",
"360"
]
},
{
"configuration": "1x50",
"cells": [
"",
"RM",
"0.393",
"60",
"13.2",
"500"
]
}
]
}
]
}} />}>
<section>
<h3 data-start="460" data-end="518">For long-term use in demanding environments</h3>
<p data-start="520" data-end="953">The <strong data-start="524" data-end="536">H1Z2Z2-K</strong> complies with <strong data-start="552" data-end="588">DIN EN 50618 (VDE 0283-618)</strong> and is specifically designed for the <strong data-start="614" data-end="654">cabling of photovoltaic systems</strong>. It can be <strong data-start="675" data-end="713">installed permanently or used flexibly</strong> – indoors, outdoors, in industrial facilities, agricultural operations, or even in <strong data-start="812" data-end="847">hazardous (explosive) areas</strong>. The cable is <strong data-start="865" data-end="905">UV-, ozone- and water-resistant (AD7)</strong> and can be <strong data-start="915" data-end="945">laid directly in the ground</strong>.</p>
<h3 data-start="955" data-end="990">Construction and technical features</h3>
<p data-start="992" data-end="1516">The finely stranded <strong data-start="1009" data-end="1045">tinned copper conductor (class 5)</strong> is double protected by <strong data-start="1079" data-end="1160">cross-linked insulation and a cross-linked outer sheath made of polyolefin copolymer</strong> – halogen-free, flame-retardant, and highly abrasion-resistant. The cable is designed for a maximum conductor temperature of <strong data-start="1273" data-end="1283">120 °C</strong> and remains reliably flexible even at <strong data-start="1314" data-end="1339">-40 °C (fixed installation)</strong>. Its <strong data-start="1366" data-end="1394">low smoke emission</strong> and high resistance to mechanical and thermal stress ensure safe, long-term operation.</p>
<h3 data-start="1518" data-end="1549">Key features at a glance</h3>
<ul data-start="1551" data-end="1815">
<li data-start="1551" data-end="1604">
<p data-start="1553" data-end="1604"><strong data-start="1553" data-end="1604">Halogen-free, flame-retardant, UV- and ozone-resistant</strong></p>
</li>
<li data-start="1605" data-end="1666">
<p data-start="1607" data-end="1666"><strong data-start="1607" data-end="1666">Short-circuit and earth fault proof according to VDE-AR-E 2283-4</strong></p>
</li>
<li data-start="1667" data-end="1744">
<p data-start="1669" data-end="1744"><strong data-start="1669" data-end="1744">Approved for indoor, outdoor and hazardous (explosive) areas</strong></p>
</li>
<li data-start="1745" data-end="1784">
<p data-start="1747" data-end="1784"><strong data-start="1747" data-end="1784">Suitable for direct burial</strong></p>
</li>
<li data-start="1785" data-end="1815">
<p data-start="1787" data-end="1815"><strong data-start="1787" data-end="1815">CPR performance class: Eca</strong></p>
</li>
</ul>
</section>
</ProductTabs>