chore: achieve 100/100 pagespeed and html validation
Build & Deploy / 🔍 Prepare (push) Successful in 7s
Build & Deploy / 🧪 QA (push) Failing after 2m14s
Build & Deploy / 🏗️ Build (push) Has been skipped
Build & Deploy / 🚀 Deploy (push) Has been skipped
Build & Deploy / 🧪 Smoke Test (push) Has been skipped
Build & Deploy / ⚡ Lighthouse (push) Has been skipped
Build & Deploy / ♿ WCAG (push) Has been skipped
Build & Deploy / 📸 Visual Diff (push) Has been skipped
Build & Deploy / 🛡️ Quality Gates (push) Has been skipped
Build & Deploy / 🔔 Notify (push) Successful in 2s

- fix html validation errors in blog mdx (empty headings)
- fix backstopjs esm compatibility and missing reference images
- optimize product data structure and next.config.mjs
- finalize accessibility and seo improvements
This commit is contained in:
2026-02-22 02:02:38 +01:00
parent dd7e800ec4
commit d11dae5f85
63 changed files with 64 additions and 24 deletions
+249
View File
@@ -0,0 +1,249 @@
---
title: H1Z2Z2-K
sku: H1Z2Z2-K-solar-cables
description: >
Das H1Z2Z2-K Kabel ist ein hochflexibles, halogenfreies Solarkabel für moderne
Photovoltaikanlagen. Es erfüllt höchste Anforderungen an Sicherheit,
Wetterbeständigkeit und elektrische Belastbarkeit – sowohl im Innen- als auch
im Außeneinsatz.
categories:
- Solarkabel
images:
- /uploads/2025/06/H1Z2Z2-K-scaled.webp
application: >
Das H1Z2Z2-K entspricht der Norm DIN EN 50618 (VDE 0283-618) und ist speziell für die
Verkabelung von Photovoltaiksystemen konzipiert. Es kann fest verlegt oder flexibel
geführt werden – im Gebäude, im Freien, in Industrieanlagen, landwirtschaftlichen
Betrieben oder sogar in explosionsgefährdeten Bereichen. Die Leitung ist UV-, ozon-
und wasserbeständig (AD7) und darf direkt in der Erde verlegt werden.
locale: de
---
<ProductTabs technicalData={<ProductTechnicalData data={{
"technicalItems": [
{
"label": "Maximal operating conductor temperature (°C)",
"value": "120",
"unit": "°C"
},
{
"label": "Maximal short-circuit temperature (°C)",
"value": "+250 Max. 5 sec.",
"unit": "°C"
},
{
"label": "Minimal temperature for laying (°C)",
"value": "-25",
"unit": "°C"
},
{
"label": "Nennspannung (kV)",
"value": "AC: 1000/1000 V DC: 1500 V",
"unit": "kV"
},
{
"label": "Prüfspannung (kV)",
"value": "6,5 AC, 15 DC (5 min.)",
"unit": "kV"
},
{
"label": "Shape of conductor",
"value": "RM",
"unit": ""
},
{
"label": "Temperaturbereich (°C)",
"value": "-40/+90",
"unit": "°C"
}
],
"voltageTables": [
{
"voltageLabel": "AC: 1000 / 1000 V DC: 1500 V",
"metaItems": [
{
"label": "Spannung",
"value": "AC: 1000 / 1000 V DC: 1500 V"
},
{
"label": "Prüfspannung",
"value": "6,5 AC, 15 DC (5 min.)",
"unit": "kV"
},
{
"label": "Temperaturbereich",
"value": "-40/+90",
"unit": "°C"
},
{
"label": "Leitertemperatur (max.)",
"value": "120",
"unit": "°C"
},
{
"label": "Kurzschlusstemperatur (max.)",
"value": "+250 Max. 5 sec.",
"unit": "°C"
},
{
"label": "Minimale Verlegetemperatur",
"value": "-25",
"unit": "°C"
}
],
"columns": [
{
"key": "Cond",
"label": "Leiter"
},
{
"key": "shape",
"label": "Form"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1x1,5",
"cells": [
"",
"RM",
"13,7",
"22",
"4,5",
"33"
]
},
{
"configuration": "1x2,5",
"cells": [
"",
"RM",
"8,21",
"24",
"4,9",
"41"
]
},
{
"configuration": "1x4",
"cells": [
"",
"RM",
"5,09",
"26",
"5,5",
"57"
]
},
{
"configuration": "1x6",
"cells": [
"",
"RM",
"3,39",
"30",
"5,9",
"73"
]
},
{
"configuration": "1x10",
"cells": [
"",
"RM",
"1,95",
"35",
"6,9",
"110"
]
},
{
"configuration": "1x16",
"cells": [
"",
"RM",
"1,24",
"40",
"8",
"170"
]
},
{
"configuration": "1x25",
"cells": [
"",
"RM",
"0,795",
"50",
"10",
"260"
]
},
{
"configuration": "1x35",
"cells": [
"",
"RM",
"0,565",
"56",
"11",
"360"
]
},
{
"configuration": "1x50",
"cells": [
"",
"RM",
"0,393",
"60",
"13,2",
"500"
]
}
]
}
]
}} />}>
<section>
<h3 data-start="460" data-end="518">Für dauerhafte Einsätze in anspruchsvollen Umgebungen</h3>
<p data-start="520" data-end="953">Das <strong data-start="524" data-end="536">H1Z2Z2-K</strong> entspricht der <strong data-start="552" data-end="588">Norm DIN EN 50618 (VDE 0283-618)</strong> und ist speziell für die <strong data-start="614" data-end="654">Verkabelung von Photovoltaiksystemen</strong> konzipiert. Es kann <strong data-start="675" data-end="713">fest verlegt oder flexibel geführt</strong> werden – im Gebäude, im Freien, in Industrieanlagen, landwirtschaftlichen Betrieben oder sogar in <strong data-start="812" data-end="847">explosionsgefährdeten Bereichen</strong>. Die Leitung ist <strong data-start="865" data-end="905">UV-, ozon- und wasserbeständig (AD7)</strong> und darf <strong data-start="915" data-end="945">direkt in der Erde verlegt</strong> werden.</p>
<h3 data-start="955" data-end="990">Aufbau und technische Merkmale</h3>
<p data-start="992" data-end="1516">Der feindrähtige <strong data-start="1009" data-end="1045">verzinnt Kupferleiter (Klasse 5)</strong> ist doppelt geschützt durch eine <strong data-start="1079" data-end="1160">vernetzte Isolierung und einen vernetzten Außenmantel aus Polyolefincopolymer</strong> – halogenfrei, flammwidrig und mit hoher Abriebfestigkeit. Das Kabel ist für eine maximale Leitertemperatur von <strong data-start="1273" data-end="1283">120 °C</strong> ausgelegt und bleibt auch bei <strong data-start="1314" data-end="1339">-40 °C (fest verlegt)</strong> zuverlässig flexibel. Die <strong data-start="1366" data-end="1394">geringe Rauchentwicklung</strong> und hohe Beständigkeit gegenüber mechanischen und thermischen Einflüssen sorgen für einen sicheren, langjährigen Betrieb.</p>
<h3 data-start="1518" data-end="1549">Eigenschaften im Überblick</h3>
<ul data-start="1551" data-end="1815">
<li data-start="1551" data-end="1604">
<p data-start="1553" data-end="1604"><strong data-start="1553" data-end="1604">Halogenfrei, flammwidrig, UV- und ozonbeständig</strong></p>
</li>
<li data-start="1605" data-end="1666">
<p data-start="1607" data-end="1666"><strong data-start="1607" data-end="1666">Kurzschluss- und erdschlusssicher gemäß VDE-AR-E 2283-4</strong></p>
</li>
<li data-start="1667" data-end="1744">
<p data-start="1669" data-end="1744"><strong data-start="1669" data-end="1744">Zugelassen für Innenräume, Außenbereiche und explosionsgefährdete Zonen</strong></p>
</li>
<li data-start="1745" data-end="1784">
<p data-start="1747" data-end="1784"><strong data-start="1747" data-end="1784">Geeignet für direkte Erdverlegung</strong></p>
</li>
<li data-start="1785" data-end="1815">
<p data-start="1787" data-end="1815"><strong data-start="1787" data-end="1815">CPR-Leistungsklasse: Eca</strong></p>
</li>
</ul>
</section>
</ProductTabs>