chore: achieve 100/100 pagespeed and html validation
Some checks failed
Build & Deploy / 🔍 Prepare (push) Successful in 7s
Build & Deploy / 🧪 QA (push) Failing after 2m14s
Build & Deploy / 🏗️ Build (push) Has been skipped
Build & Deploy / 🚀 Deploy (push) Has been skipped
Build & Deploy / 🧪 Smoke Test (push) Has been skipped
Build & Deploy / ⚡ Lighthouse (push) Has been skipped
Build & Deploy / ♿ WCAG (push) Has been skipped
Build & Deploy / 📸 Visual Diff (push) Has been skipped
Build & Deploy / 🛡️ Quality Gates (push) Has been skipped
Build & Deploy / 🔔 Notify (push) Successful in 2s
Some checks failed
Build & Deploy / 🔍 Prepare (push) Successful in 7s
Build & Deploy / 🧪 QA (push) Failing after 2m14s
Build & Deploy / 🏗️ Build (push) Has been skipped
Build & Deploy / 🚀 Deploy (push) Has been skipped
Build & Deploy / 🧪 Smoke Test (push) Has been skipped
Build & Deploy / ⚡ Lighthouse (push) Has been skipped
Build & Deploy / ♿ WCAG (push) Has been skipped
Build & Deploy / 📸 Visual Diff (push) Has been skipped
Build & Deploy / 🛡️ Quality Gates (push) Has been skipped
Build & Deploy / 🔔 Notify (push) Successful in 2s
- fix html validation errors in blog mdx (empty headings) - fix backstopjs esm compatibility and missing reference images - optimize product data structure and next.config.mjs - finalize accessibility and seo improvements
This commit is contained in:
246
data/products/de/hochspannungskabel/na2xfkld2y.mdx
Normal file
246
data/products/de/hochspannungskabel/na2xfkld2y.mdx
Normal file
@@ -0,0 +1,246 @@
|
||||
---
|
||||
title: NA2X(F)KLD2Y
|
||||
sku: NA2X(F)KLD2Y-high-voltage-cables
|
||||
description: >
|
||||
Die NA2X(F)KLD2Y-Hochspannungskabelserie ist speziell für hohe
|
||||
Spannungsklassen (64/110kV) konzipiert und verwendet hochleitfähige
|
||||
Kupferleiter, ideal für industrielle Anwendungen, die hohe Strombelastbarkeit
|
||||
und Durchschlagsfestigkeit erfordern.
|
||||
categories:
|
||||
- Hochspannungskabel
|
||||
images: []
|
||||
application: >
|
||||
Die NA2X(F)KLD2Y-Hochspannungskabelserie ist für den Einsatz in
|
||||
Hochspannungsanwendungen konzipiert und bietet eine optimale Lösung für
|
||||
anspruchsvolle industrielle Umgebungen. Mit ihrer fortschrittlichen
|
||||
XLPE-Isolierung und Kupferleitern erfüllt sie hohe Anforderungen an die
|
||||
Durchschlagsfestigkeit und Thermozyklierung.
|
||||
locale: de
|
||||
---
|
||||
<ProductTabs technicalData={<ProductTechnicalData data={{
|
||||
"technicalItems": [
|
||||
{
|
||||
"label": "Nennspannung (kV)",
|
||||
"value": "64/110",
|
||||
"unit": "kV"
|
||||
}
|
||||
],
|
||||
"voltageTables": [
|
||||
{
|
||||
"voltageLabel": "64/110 kV",
|
||||
"metaItems": [
|
||||
{
|
||||
"label": "Spannung",
|
||||
"value": "64/110 kV"
|
||||
}
|
||||
],
|
||||
"columns": [
|
||||
{
|
||||
"key": "Cond",
|
||||
"label": "Leiter"
|
||||
},
|
||||
{
|
||||
"key": "RI",
|
||||
"label": "RI [Ohm/km]"
|
||||
},
|
||||
{
|
||||
"key": "Wi",
|
||||
"label": "Wi [mm]"
|
||||
},
|
||||
{
|
||||
"key": "Rbv",
|
||||
"label": "Rbv [mm]"
|
||||
},
|
||||
{
|
||||
"key": "Ø",
|
||||
"label": "Ø [mm]"
|
||||
},
|
||||
{
|
||||
"key": "G",
|
||||
"label": "G [kg/km]"
|
||||
}
|
||||
],
|
||||
"rows": [
|
||||
{
|
||||
"configuration": "1×240RM",
|
||||
"cells": [
|
||||
"Al",
|
||||
"0,16",
|
||||
"16,5",
|
||||
"2,1",
|
||||
"86",
|
||||
"5510"
|
||||
]
|
||||
},
|
||||
{
|
||||
"configuration": "1×300RM",
|
||||
"cells": [
|
||||
"Al",
|
||||
"0,13",
|
||||
"15,5",
|
||||
"2,2",
|
||||
"86",
|
||||
"5630"
|
||||
]
|
||||
},
|
||||
{
|
||||
"configuration": "1×400RM",
|
||||
"cells": [
|
||||
"Al",
|
||||
"0,1",
|
||||
"14,5",
|
||||
"2,2",
|
||||
"87",
|
||||
"5750"
|
||||
]
|
||||
},
|
||||
{
|
||||
"configuration": "1×500RM",
|
||||
"cells": [
|
||||
"Al",
|
||||
"0,08",
|
||||
"14",
|
||||
"2,3",
|
||||
"90",
|
||||
"6380"
|
||||
]
|
||||
},
|
||||
{
|
||||
"configuration": "1×630RM",
|
||||
"cells": [
|
||||
"Al",
|
||||
"0,06",
|
||||
"14",
|
||||
"2,4",
|
||||
"94",
|
||||
"7000"
|
||||
]
|
||||
},
|
||||
{
|
||||
"configuration": "1×800RM",
|
||||
"cells": [
|
||||
"Al",
|
||||
"0,05",
|
||||
"14",
|
||||
"2,5",
|
||||
"98",
|
||||
"7960"
|
||||
]
|
||||
},
|
||||
{
|
||||
"configuration": "1×1000RM",
|
||||
"cells": [
|
||||
"Al",
|
||||
"0,04",
|
||||
"14",
|
||||
"2,6",
|
||||
"103",
|
||||
"9030"
|
||||
]
|
||||
},
|
||||
{
|
||||
"configuration": "1×1200RMS",
|
||||
"cells": [
|
||||
"Al",
|
||||
"0,03",
|
||||
"14",
|
||||
"2,8",
|
||||
"112",
|
||||
"10450"
|
||||
]
|
||||
},
|
||||
{
|
||||
"configuration": "1×1400RMS",
|
||||
"cells": [
|
||||
"Al",
|
||||
"0,03",
|
||||
"14",
|
||||
"2,8",
|
||||
"114",
|
||||
"11190"
|
||||
]
|
||||
},
|
||||
{
|
||||
"configuration": "1×1600RMS",
|
||||
"cells": [
|
||||
"Al",
|
||||
"0,02",
|
||||
"14",
|
||||
"2,9",
|
||||
"118",
|
||||
"12140"
|
||||
]
|
||||
},
|
||||
{
|
||||
"configuration": "1×1800RMS",
|
||||
"cells": [
|
||||
"Al",
|
||||
"0,02",
|
||||
"14",
|
||||
"3,1",
|
||||
"122",
|
||||
"13220"
|
||||
]
|
||||
},
|
||||
{
|
||||
"configuration": "1×2000RMS",
|
||||
"cells": [
|
||||
"Al",
|
||||
"0,02",
|
||||
"14",
|
||||
"3,1",
|
||||
"124",
|
||||
"13900"
|
||||
]
|
||||
},
|
||||
{
|
||||
"configuration": "1×2500RMS",
|
||||
"cells": [
|
||||
"Al",
|
||||
"0,02",
|
||||
"14,5",
|
||||
"3,3",
|
||||
"133",
|
||||
"15970"
|
||||
]
|
||||
},
|
||||
{
|
||||
"configuration": "1×3000RMS",
|
||||
"cells": [
|
||||
"Al",
|
||||
"0,01",
|
||||
"14,5",
|
||||
"3,5",
|
||||
"141",
|
||||
"18720"
|
||||
]
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
}} />}>
|
||||
|
||||
<section>
|
||||
<h2>Technische Übersicht</h2>
|
||||
<p>Die <strong>NA2X(F)KLD2Y-Hochspannungskabelserie</strong> ist für den Einsatz in Hochspannungsanwendungen konzipiert und bietet eine optimale Lösung für anspruchsvolle industrielle Umgebungen. Mit ihrer fortschrittlichen XLPE-Isolierung und Kupferleitern erfüllt sie hohe Anforderungen an die <strong>Durchschlagsfestigkeit</strong> und <strong>Thermozyklierung</strong>.</p>
|
||||
</section>
|
||||
<section>
|
||||
<h2>Technische Leistung und Konstruktion</h2>
|
||||
<p>Die Kabelserie ist entwickelt, um eine hohe <strong>Strombelastbarkeit</strong> und <strong>Kurzschlussstromfestigkeit</strong> zu gewährleisten. Die Verwendung von hochreinem Kupfer maximiert die Leitfähigkeit und unterstützt effiziente Energieübertragung. Die XLPE-Isolierung bietet eine hervorragende thermische Beständigkeit und ermöglicht den Einsatz in verschiedenen thermischen Bedingungen.</p>
|
||||
<ul>
|
||||
<li>Verstärkte Isolierung für verbesserte <strong>Durchschlagsfestigkeit</strong></li>
|
||||
<li>Optimierte Kabelgeometrie zur Unterstützung der <strong>elektromagnetischen Verträglichkeit</strong> (EMV)</li>
|
||||
<li>Effektive Spannungsinduzierungsreduktion durch spezielle Abschirmtechniken</li>
|
||||
</ul>
|
||||
</section>
|
||||
<section>
|
||||
<h2>Installations- und Normkonformität</h2>
|
||||
<p>Die NA2X(F)KLD2Y-Kabelserie unterstützt diverse Verlegeverfahren wie <strong>Erdverlegung</strong>, <strong>Kabeltrassen-Montage</strong> und <strong>Kleeblattformation</strong>, was ihre Vielseitigkeit in der praktischen Anwendung unterstreicht. Sie entspricht den internationalen Normen, inklusive <strong>IEC-Konformität</strong>, <strong>CPR-Klassifizierung</strong> und trägt die <strong>CE-Kennzeichnung</strong>.</p>
|
||||
<ul>
|
||||
<li>Anpassungsfähigkeit an verschiedene Verlegebedingungen und Umgebungen</li>
|
||||
<li>Einhaltung strenger internationaler und europäischer Standards</li>
|
||||
<li>Verfügbar in mehreren Konfigurationen, um spezifische Anforderungen zu erfüllen</li>
|
||||
</ul>
|
||||
</section>
|
||||
|
||||