chore: achieve 100/100 pagespeed and html validation
Some checks failed
Build & Deploy / 🔍 Prepare (push) Successful in 7s
Build & Deploy / 🧪 QA (push) Failing after 2m14s
Build & Deploy / 🏗️ Build (push) Has been skipped
Build & Deploy / 🚀 Deploy (push) Has been skipped
Build & Deploy / 🧪 Smoke Test (push) Has been skipped
Build & Deploy / ⚡ Lighthouse (push) Has been skipped
Build & Deploy / ♿ WCAG (push) Has been skipped
Build & Deploy / 📸 Visual Diff (push) Has been skipped
Build & Deploy / 🛡️ Quality Gates (push) Has been skipped
Build & Deploy / 🔔 Notify (push) Successful in 2s

- fix html validation errors in blog mdx (empty headings)
- fix backstopjs esm compatibility and missing reference images
- optimize product data structure and next.config.mjs
- finalize accessibility and seo improvements
This commit is contained in:
2026-02-22 02:02:38 +01:00
parent dd7e800ec4
commit d11dae5f85
63 changed files with 64 additions and 24 deletions

View File

@@ -0,0 +1,264 @@
---
title: N2X(F)K2Y
sku: N2X(F)K2Y-high-voltage-cables
description: >
Die N2X(F)K2Y-Hochspannungskabelserie ist für Spannungsklassen von 64/110kV
ausgelegt und verwendet hochleitfähige Kupferleiter, ideal für anspruchsvolle
industrielle und infrastrukturelle Anwendungen, einschließlich Erdverlegung
und Kabeltrassen-Montage.
categories:
- Hochspannungskabel
images: []
application: >
Die N2X(F)K2Y-Hochspannungskabelserie ist speziell für den Einsatz in
Hochspannungsanwendungen konzipiert, wobei sie eine optimale Leistung durch die
Verwendung von hochleitfähigem Kupfer und einer fortschrittlichen XLPE-Isolierung
bietet. Diese Kombination gewährleistet eine hohe Durchschlagsfestigkeit und eine
effiziente Thermozyklierung unter verschiedenen Betriebsbedingungen.
locale: de
---
<ProductTabs technicalData={<ProductTechnicalData data={{
"technicalItems": [
{
"label": "Nennspannung (kV)",
"value": "64/110",
"unit": "kV"
}
],
"voltageTables": [
{
"voltageLabel": "64/110 kV",
"metaItems": [
{
"label": "Spannung",
"value": "64/110 kV"
}
],
"columns": [
{
"key": "Cond",
"label": "Leiter"
},
{
"key": "RI",
"label": "RI [Ohm/km]"
},
{
"key": "Wi",
"label": "Wi [mm]"
},
{
"key": "Rbv",
"label": "Rbv [mm]"
},
{
"key": "Ø",
"label": "Ø [mm]"
},
{
"key": "G",
"label": "G [kg/km]"
}
],
"rows": [
{
"configuration": "1×150RM",
"cells": [
"Cu",
"0,16",
"18",
"1,4",
"67",
"8300"
]
},
{
"configuration": "1×185RM",
"cells": [
"Cu",
"0,13",
"17",
"1,3",
"66",
"8400"
]
},
{
"configuration": "1×240RM",
"cells": [
"Cu",
"0,1",
"16,5",
"1,4",
"67",
"9030"
]
},
{
"configuration": "1×300RM",
"cells": [
"Cu",
"0,08",
"15,5",
"1,4",
"67",
"9540"
]
},
{
"configuration": "1×400RM",
"cells": [
"Cu",
"0,06",
"14,5",
"1,4",
"69",
"10410"
]
},
{
"configuration": "1×500RM",
"cells": [
"Cu",
"0,05",
"14",
"1,4",
"71",
"11590"
]
},
{
"configuration": "1×630RM",
"cells": [
"Cu",
"0,04",
"14",
"1,5",
"75",
"13470"
]
},
{
"configuration": "1×800RM",
"cells": [
"Cu",
"0,03",
"14",
"1,6",
"80",
"15590"
]
},
{
"configuration": "1×1000RM",
"cells": [
"Cu",
"0,03",
"14",
"1,7",
"84",
"17980"
]
},
{
"configuration": "1×1200RMS",
"cells": [
"Cu",
"0,02",
"14",
"1,8",
"89",
"20530"
]
},
{
"configuration": "1×1400RMS",
"cells": [
"Cu",
"0,02",
"14",
"1,9",
"94",
"22780"
]
},
{
"configuration": "1×1600RMS",
"cells": [
"Cu",
"0,02",
"14",
"2",
"98",
"25280"
]
},
{
"configuration": "1×1800RMS",
"cells": [
"Cu",
"0,02",
"14",
"2",
"102",
"27940"
]
},
{
"configuration": "1×2000RMS",
"cells": [
"Cu",
"0,02",
"14",
"2,1",
"103",
"29610"
]
},
{
"configuration": "1×2500RMS",
"cells": [
"Cu",
"0,01",
"14,5",
"2,2",
"112",
"35400"
]
},
{
"configuration": "1×3000RMS",
"cells": [
"Cu",
"0,01",
"14,5",
"2,4",
"121",
"42420"
]
}
]
}
]
}} />}>
<section>
<h2>Technische Übersicht</h2>
<p>Die <strong>N2X(F)K2Y-Hochspannungskabelserie</strong> ist speziell für den Einsatz in Hochspannungsanwendungen konzipiert, wobei sie eine optimale Leistung durch die Verwendung von hochleitfähigem Kupfer und einer fortschrittlichen XLPE-Isolierung bietet. Diese Kombination gewährleistet eine hohe Durchschlagsfestigkeit und eine effiziente Thermozyklierung unter verschiedenen Betriebsbedingungen.</p>
</section>
<section>
<h2>Technische Leistung und Konstruktion</h2>
<p>Die Kabel der N2X(F)K2Y-Serie sind für ihre hohe <strong>Strombelastbarkeit</strong> und <strong>Kurzschlussstromfestigkeit</strong> bekannt, was sie zu einer zuverlässigen Wahl für kritische Infrastrukturen macht. Die <strong>elektromagnetische Verträglichkeit</strong> wird durch eine sorgfältige Konstruktion sichergestellt, die Spannungsinduzierungen minimiert und die Signalintegrität in komplexen Installationsszenarien bewahrt.</p>
<ul>
<li>Verwendung von hochreinem Kupfer für maximale Leitfähigkeit und geringe Widerstandsverluste</li>
<li>XLPE-Isolierung für verbesserte dielektrische Stärke und thermische Beständigkeit</li>
<li>Entwickelt für Verlegung in <strong>Kleeblattformation</strong> und <strong>Erdverlegung</strong>, optimiert für mechanische Stabilität und Wärmeableitung</li>
</ul>
</section>
<section>
<h2>Normen und Konformität</h2>
<p>Die Kabel entsprechen den internationalen Normen, einschließlich <strong>IEC-Konformität</strong> und <strong>CPR-Klassifizierung</strong>, und sind mit der <strong>CE-Kennzeichnung</strong> versehen. Diese Zertifizierungen bestätigen die Eignung der Kabel für den Einsatz unter den anspruchsvollsten Bedingungen und garantieren eine hohe Sicherheit und Zuverlässigkeit.</p>
<p>Verfügbar in mehreren Konfigurationen, um den unterschiedlichen Anforderungen der Projekte gerecht zu werden, bietet die N2X(F)K2Y-Serie eine flexible Lösung für Hochspannungsanwendungen.</p>
</section>
</ProductTabs>