wip
This commit is contained in:
@@ -12,20 +12,7 @@ images:
|
||||
- /uploads/2025/01/NY2Y-scaled.webp
|
||||
locale: en
|
||||
---
|
||||
# NY2Y
|
||||
|
||||
<section>
|
||||
<h3 data-start="518" data-end="554">Reliable under heavy load</h3>
|
||||
<p data-start="556" data-end="987">The <strong data-start="560" data-end="568">NY2Y</strong> is a low-voltage cable for use in power plants, industrial facilities, switching stations, and local distribution networks. It is suitable for <strong data-start="706" data-end="792">fixed installation indoors, in cable ducts, outdoors, in water, and underground</strong> – wherever strong mechanical stress is expected during installation and operation. The construction complies with <strong data-start="934" data-end="953">TP PRAKAB 16/03</strong> based on <strong data-start="970" data-end="986">VDE 0276-603</strong>.</p>
|
||||
<h3 data-start="989" data-end="1010">Detailed construction</h3>
|
||||
<p data-start="1012" data-end="1431">The cable consists of a <strong data-start="1040" data-end="1056">copper conductor</strong>, available as solid round (RE), stranded round (RM), or sector-shaped stranded (SM). The <strong data-start="1156" data-end="1177">PVC core insulation</strong> ensures electrical safety, while the cores are stranded together and protected by a common <strong data-start="1262" data-end="1284">EPDM sheath</strong>. The outer sheath made of <strong data-start="1316" data-end="1324">HDPE</strong> (black, UV-resistant) makes the NY2Y particularly resistant to abrasion, moisture, and environmental influences.</p>
|
||||
<h3 data-start="1433" data-end="1462">Typical applications</h3>
|
||||
<p data-start="1464" data-end="1802">NY2Y is ideally suited for applications with increased requirements for <strong data-start="1540" data-end="1566">mechanical strength</strong> and <strong data-start="1571" data-end="1598">weather resistance</strong>. Typical fields of use include power distribution in industrial plants, power stations, or transformer stations – but also in environments with moisture, direct sunlight, or chemical exposure.</p>
|
||||
</section>
|
||||
|
||||
## Technical Data
|
||||
|
||||
<ProductTechnicalData data={{
|
||||
<ProductTabs technicalData={<ProductTechnicalData data={{
|
||||
"technicalItems": [
|
||||
{
|
||||
"label": "Bending radius (mm)",
|
||||
@@ -503,4 +490,15 @@ locale: en
|
||||
]
|
||||
}
|
||||
]
|
||||
}} />
|
||||
}} />}>
|
||||
|
||||
<section>
|
||||
<h3 data-start="518" data-end="554">Reliable under heavy load</h3>
|
||||
<p data-start="556" data-end="987">The <strong data-start="560" data-end="568">NY2Y</strong> is a low-voltage cable for use in power plants, industrial facilities, switching stations, and local distribution networks. It is suitable for <strong data-start="706" data-end="792">fixed installation indoors, in cable ducts, outdoors, in water, and underground</strong> – wherever strong mechanical stress is expected during installation and operation. The construction complies with <strong data-start="934" data-end="953">TP PRAKAB 16/03</strong> based on <strong data-start="970" data-end="986">VDE 0276-603</strong>.</p>
|
||||
<h3 data-start="989" data-end="1010">Detailed construction</h3>
|
||||
<p data-start="1012" data-end="1431">The cable consists of a <strong data-start="1040" data-end="1056">copper conductor</strong>, available as solid round (RE), stranded round (RM), or sector-shaped stranded (SM). The <strong data-start="1156" data-end="1177">PVC core insulation</strong> ensures electrical safety, while the cores are stranded together and protected by a common <strong data-start="1262" data-end="1284">EPDM sheath</strong>. The outer sheath made of <strong data-start="1316" data-end="1324">HDPE</strong> (black, UV-resistant) makes the NY2Y particularly resistant to abrasion, moisture, and environmental influences.</p>
|
||||
<h3 data-start="1433" data-end="1462">Typical applications</h3>
|
||||
<p data-start="1464" data-end="1802">NY2Y is ideally suited for applications with increased requirements for <strong data-start="1540" data-end="1566">mechanical strength</strong> and <strong data-start="1571" data-end="1598">weather resistance</strong>. Typical fields of use include power distribution in industrial plants, power stations, or transformer stations – but also in environments with moisture, direct sunlight, or chemical exposure.</p>
|
||||
</section>
|
||||
|
||||
</ProductTabs>
|
||||
|
||||
Reference in New Issue