@@ -12,20 +12,7 @@ images:
- /uploads/2025/01/NAYCWY-scaled.webp
locale: en
---
# NAYCWY
<section>
<h3 data-start="540" data-end="595">Designed for increased safety requirements</h3>
<p data-start="597" data-end="998">The <strong data-start="601" data-end="611">NAYCWY</strong> complies with <strong data-start="632" data-end="661">DIN VDE 0276-603 (HD 603)</strong> and is suitable for use in <strong data-start="697" data-end="760">power plants, industrial facilities, switching stations, and local networks</strong>. It can be permanently installed indoors, in cable ducts, outdoors, underground, or in water. Thanks to its concentric conductor, it offers additional protection in case of mechanical damage and enables safe potential equalization.</p>
<h3 data-start="1000" data-end="1023">Technical construction</h3>
<p data-start="1025" data-end="1497">The electrical conductor consists of <strong data-start="1060" data-end="1073">aluminium</strong>, available as stranded round (RM), sector-shaped solid (SE), or stranded (SM). The <strong data-start="1164" data-end="1185">PVC core insulation</strong> and a <strong data-start="1195" data-end="1228">common EPDM sheath</strong> protect the stranded cores. On top lies a <strong data-start="1278" data-end="1329">concentric conductor made of bare copper wires</strong> with copper tape counter helix ideally usable as <strong data-start="1372" data-end="1394">PE or PEN conductor</strong>. A black <strong data-start="1422" data-end="1451">UV-resistant PVC sheath</strong> reliably seals the cable from the outside.</p>
<h3 data-start="1499" data-end="1532">Application and special features</h3>
<p data-start="1534" data-end="1894"><strong>NAYCWY</strong> cables are used wherever <strong data-start="1583" data-end="1623">electrical safety and shielding</strong> are required. The concentric conductor does not need to be separated when connecting to branch joints, which simplifies installation. This makes the cable particularly suitable for modern low-voltage networks with increased requirements for operational safety and contact protection.</p>
</section>
## Technical Data
<ProductTechnicalData data={{
<ProductTabs technicalData={<ProductTechnicalData data={{
"technicalItems": [
{
"label": "Bending radius (mm)",
@@ -802,4 +789,15 @@ locale: en
]
}
]
}} />
}} />}>
<section>
<h3 data-start="540" data-end="595">Designed for increased safety requirements</h3>
<p data-start="597" data-end="998">The <strong data-start="601" data-end="611">NAYCWY</strong> complies with <strong data-start="632" data-end="661">DIN VDE 0276-603 (HD 603)</strong> and is suitable for use in <strong data-start="697" data-end="760">power plants, industrial facilities, switching stations, and local networks</strong>. It can be permanently installed indoors, in cable ducts, outdoors, underground, or in water. Thanks to its concentric conductor, it offers additional protection in case of mechanical damage and enables safe potential equalization.</p>
<h3 data-start="1000" data-end="1023">Technical construction</h3>
<p data-start="1025" data-end="1497">The electrical conductor consists of <strong data-start="1060" data-end="1073">aluminium</strong>, available as stranded round (RM), sector-shaped solid (SE), or stranded (SM). The <strong data-start="1164" data-end="1185">PVC core insulation</strong> and a <strong data-start="1195" data-end="1228">common EPDM sheath</strong> protect the stranded cores. On top lies a <strong data-start="1278" data-end="1329">concentric conductor made of bare copper wires</strong> with copper tape counter helix ideally usable as <strong data-start="1372" data-end="1394">PE or PEN conductor</strong>. A black <strong data-start="1422" data-end="1451">UV-resistant PVC sheath</strong> reliably seals the cable from the outside.</p>
<h3 data-start="1499" data-end="1532">Application and special features</h3>
<p data-start="1534" data-end="1894"><strong>NAYCWY</strong> cables are used wherever <strong data-start="1583" data-end="1623">electrical safety and shielding</strong> are required. The concentric conductor does not need to be separated when connecting to branch joints, which simplifies installation. This makes the cable particularly suitable for modern low-voltage networks with increased requirements for operational safety and contact protection.</p>
</section>