This commit is contained in:
2026-01-17 01:50:54 +01:00
parent c12b32ed5e
commit c8f61257c9
62 changed files with 1297 additions and 1028 deletions

View File

@@ -12,20 +12,7 @@ images:
- /uploads/2025/01/NA2XY-scaled.webp
locale: en
---
# NA2XY
<section>
<h3 data-start="511" data-end="550">For demanding network applications</h3>
<p data-start="552" data-end="901">The <strong data-start="556" data-end="565">NA2XY</strong> complies with <strong data-start="586" data-end="615">DIN VDE 0276-603 (HD 603)</strong> and is ideal for fixed installation in <strong data-start="657" data-end="725">indoor spaces, cable ducts, outdoors, in water, or underground</strong>. Typical areas of application include <strong data-start="762" data-end="809">power plants, industrial facilities, and switching stations</strong> as well as <strong data-start="816" data-end="829">local distribution networks</strong>, where mechanical stress during operation must be considered.</p>
<h3 data-start="903" data-end="926">Technical construction</h3>
<p data-start="928" data-end="1288">The conductor is made of <strong data-start="951" data-end="964">aluminium</strong>, available as solid round (RE) or stranded round (RM). The cores are insulated with <strong data-start="1048" data-end="1077">PE (polyethylene)</strong>, which provides excellent electrical insulation and high thermal resistance. The black <strong data-start="1187" data-end="1201">PVC sheath</strong> is <strong data-start="1206" data-end="1222">UV-resistant</strong> and reliably protects against moisture and environmental influences.</p>
<h3 data-start="1290" data-end="1310">Fields of application</h3>
<p data-start="1312" data-end="1582">NA2XY cables are the right choice for <strong data-start="1351" data-end="1427">stable power distribution under mechanically demanding conditions</strong>. They provide an economical, durable solution for utilities, industry, and plant operators who rely on proven technology and high resilience.</p>
</section>
## Technical Data
<ProductTechnicalData data={{
<ProductTabs technicalData={<ProductTechnicalData data={{
"technicalItems": [
{
"label": "Bending radius (mm)",
@@ -880,4 +867,15 @@ locale: en
]
}
]
}} />
}} />}>
<section>
<h3 data-start="511" data-end="550">For demanding network applications</h3>
<p data-start="552" data-end="901">The <strong data-start="556" data-end="565">NA2XY</strong> complies with <strong data-start="586" data-end="615">DIN VDE 0276-603 (HD 603)</strong> and is ideal for fixed installation in <strong data-start="657" data-end="725">indoor spaces, cable ducts, outdoors, in water, or underground</strong>. Typical areas of application include <strong data-start="762" data-end="809">power plants, industrial facilities, and switching stations</strong> as well as <strong data-start="816" data-end="829">local distribution networks</strong>, where mechanical stress during operation must be considered.</p>
<h3 data-start="903" data-end="926">Technical construction</h3>
<p data-start="928" data-end="1288">The conductor is made of <strong data-start="951" data-end="964">aluminium</strong>, available as solid round (RE) or stranded round (RM). The cores are insulated with <strong data-start="1048" data-end="1077">PE (polyethylene)</strong>, which provides excellent electrical insulation and high thermal resistance. The black <strong data-start="1187" data-end="1201">PVC sheath</strong> is <strong data-start="1206" data-end="1222">UV-resistant</strong> and reliably protects against moisture and environmental influences.</p>
<h3 data-start="1290" data-end="1310">Fields of application</h3>
<p data-start="1312" data-end="1582">NA2XY cables are the right choice for <strong data-start="1351" data-end="1427">stable power distribution under mechanically demanding conditions</strong>. They provide an economical, durable solution for utilities, industry, and plant operators who rely on proven technology and high resilience.</p>
</section>
</ProductTabs>