@@ -12,20 +12,7 @@ images:
- /uploads/2025/01/NA2XSF2Y-3-scaled.webp
locale: en
---
# NA2XS(F)2Y
<section>
<h3 data-start="508" data-end="575">For high-performance power networks with enhanced protection requirements</h3>
<p data-start="577" data-end="994">The <strong data-start="581" data-end="595">NA2XS(F)2Y</strong> complies with standards <strong data-start="618" data-end="638">DIN VDE 0276-620</strong>, <strong data-start="640" data-end="653">HD 620 S2</strong> and <strong data-start="658" data-end="671">IEC 60502</strong>. It is suitable for <strong data-start="696" data-end="797">installation indoors, in cable ducts, underground, in water, outdoors, or on cable trays</strong>. Its main applications are in <strong data-start="831" data-end="881">utility grids, industrial facilities, and substations</strong>, where additional safety reserves against moisture ingress and mechanical stress are required.</p>
<h3 data-start="996" data-end="1033">Construction and material characteristics</h3>
<p data-start="1035" data-end="1537">The conductor consists of <strong data-start="1058" data-end="1085">multi-stranded aluminium</strong> (Class 2), surrounded by an <strong data-start="1116" data-end="1139">inner conductive layer</strong> and <strong data-start="1150" data-end="1168">XLPE insulation</strong> with a tightly bonded outer conductive layer extruded in a single process for maximum operational safety. The shielding is provided by a <strong data-start="1309" data-end="1354">copper wire braid with counter helix</strong>, complemented by a <strong data-start="1375" data-end="1407">longitudinally watertight tape</strong>. The outer sheath is made of <strong data-start="1437" data-end="1464">black PE (Type DMP2)</strong> and reliably protects against mechanical stress and moisture.</p>
<h3 data-start="1539" data-end="1577">Properties and fields of application</h3>
<p data-start="1579" data-end="1977">The NA2XS(F)2Y is <strong data-start="1598" data-end="1614">suitable for underground installation</strong>, <strong data-start="1616" data-end="1644">free from silicone and cadmium</strong>, and <strong data-start="1651" data-end="1704">resistant to paint-wetting impairment substances</strong>. It withstands <strong data-start="1714" data-end="1746">continuous temperatures up to +90°C</strong> and tolerates <strong data-start="1767" data-end="1805">short-circuit loads up to +250°C</strong>. Thanks to its well-designed, partial discharge-free structure, it is particularly well suited for <strong data-start="1900" data-end="1976">safe power distribution in moist and complex installation environments</strong>.</p>
</section>
## Technical Data
<ProductTechnicalData data={{
<ProductTabs technicalData={<ProductTechnicalData data={{
"technicalItems": [
{
"label": "CPR class",
@@ -1087,4 +1074,15 @@ locale: en
]
}
]
}} />
}} />}>
<section>
<h3 data-start="508" data-end="575">For high-performance power networks with enhanced protection requirements</h3>
<p data-start="577" data-end="994">The <strong data-start="581" data-end="595">NA2XS(F)2Y</strong> complies with standards <strong data-start="618" data-end="638">DIN VDE 0276-620</strong>, <strong data-start="640" data-end="653">HD 620 S2</strong> and <strong data-start="658" data-end="671">IEC 60502</strong>. It is suitable for <strong data-start="696" data-end="797">installation indoors, in cable ducts, underground, in water, outdoors, or on cable trays</strong>. Its main applications are in <strong data-start="831" data-end="881">utility grids, industrial facilities, and substations</strong>, where additional safety reserves against moisture ingress and mechanical stress are required.</p>
<h3 data-start="996" data-end="1033">Construction and material characteristics</h3>
<p data-start="1035" data-end="1537">The conductor consists of <strong data-start="1058" data-end="1085">multi-stranded aluminium</strong> (Class 2), surrounded by an <strong data-start="1116" data-end="1139">inner conductive layer</strong> and <strong data-start="1150" data-end="1168">XLPE insulation</strong> with a tightly bonded outer conductive layer extruded in a single process for maximum operational safety. The shielding is provided by a <strong data-start="1309" data-end="1354">copper wire braid with counter helix</strong>, complemented by a <strong data-start="1375" data-end="1407">longitudinally watertight tape</strong>. The outer sheath is made of <strong data-start="1437" data-end="1464">black PE (Type DMP2)</strong> and reliably protects against mechanical stress and moisture.</p>
<h3 data-start="1539" data-end="1577">Properties and fields of application</h3>
<p data-start="1579" data-end="1977">The NA2XS(F)2Y is <strong data-start="1598" data-end="1614">suitable for underground installation</strong>, <strong data-start="1616" data-end="1644">free from silicone and cadmium</strong>, and <strong data-start="1651" data-end="1704">resistant to paint-wetting impairment substances</strong>. It withstands <strong data-start="1714" data-end="1746">continuous temperatures up to +90°C</strong> and tolerates <strong data-start="1767" data-end="1805">short-circuit loads up to +250°C</strong>. Thanks to its well-designed, partial discharge-free structure, it is particularly well suited for <strong data-start="1900" data-end="1976">safe power distribution in moist and complex installation environments</strong>.</p>
</section>