wip
This commit is contained in:
@@ -12,20 +12,7 @@ images:
|
||||
- /uploads/2025/01/N2X2Y-scaled.webp
|
||||
locale: en
|
||||
---
|
||||
# N2X2Y
|
||||
|
||||
<section>
|
||||
<h3 data-start="448" data-end="491">For demanding operating conditions</h3>
|
||||
<p data-start="493" data-end="945">The <strong data-start="497" data-end="506">N2X2Y</strong> complies with <strong data-start="529" data-end="550">HD 603 S1 Part 5G</strong> and <strong data-start="555" data-end="576">HD 627 S1 Part 4H</strong> (equivalent to <strong data-start="596" data-end="616">DIN VDE 0276-603</strong> and <strong data-start="621" data-end="629">-627</strong>) and is designed for an <strong data-start="648" data-end="678">operating frequency of 50 Hz</strong>. It is suitable for fixed installation indoors, underground, outdoors, and in industrial environments with high temperature and load requirements. The maximum operating temperature is <strong data-start="888" data-end="898">+90 °C</strong>, and <strong data-start="924" data-end="935">+250 °C</strong> is permissible under short-circuit conditions.</p>
|
||||
<h3 data-start="947" data-end="982">Construction and technical features</h3>
|
||||
<p data-start="984" data-end="1334">The cable structure consists of <strong data-start="1012" data-end="1029">copper conductors</strong> with <strong data-start="1034" data-end="1076">XLPE insulation (cross-linked polyethylene)</strong>. The cores are stranded and surrounded by a robust <strong data-start="1126" data-end="1151">black HDPE sheath</strong>. The integrated <strong data-start="1177" data-end="1201">concentric conductor</strong> made of copper wires is grounded at both ends and provides effective protection against potential differences and contact voltages.</p>
|
||||
<h3 data-start="1336" data-end="1355">Fields of application</h3>
|
||||
<p data-start="1357" data-end="1663">N2X2Y is ideal for installations in <strong data-start="1395" data-end="1442">local networks, substations, and industrial plants</strong> as well as in <strong data-start="1447" data-end="1470">power distribution systems</strong>, where high <strong data-start="1487" data-end="1515">thermal endurance</strong> and <strong data-start="1520" data-end="1552">mechanical strength</strong> are required. It provides a durable solution for demanding operating conditions – reliable and safe.</p>
|
||||
</section>
|
||||
|
||||
## Technical Data
|
||||
|
||||
<ProductTechnicalData data={{
|
||||
<ProductTabs technicalData={<ProductTechnicalData data={{
|
||||
"technicalItems": [
|
||||
{
|
||||
"label": "Bending radius (mm)",
|
||||
@@ -828,4 +815,15 @@ locale: en
|
||||
]
|
||||
}
|
||||
]
|
||||
}} />
|
||||
}} />}>
|
||||
|
||||
<section>
|
||||
<h3 data-start="448" data-end="491">For demanding operating conditions</h3>
|
||||
<p data-start="493" data-end="945">The <strong data-start="497" data-end="506">N2X2Y</strong> complies with <strong data-start="529" data-end="550">HD 603 S1 Part 5G</strong> and <strong data-start="555" data-end="576">HD 627 S1 Part 4H</strong> (equivalent to <strong data-start="596" data-end="616">DIN VDE 0276-603</strong> and <strong data-start="621" data-end="629">-627</strong>) and is designed for an <strong data-start="648" data-end="678">operating frequency of 50 Hz</strong>. It is suitable for fixed installation indoors, underground, outdoors, and in industrial environments with high temperature and load requirements. The maximum operating temperature is <strong data-start="888" data-end="898">+90 °C</strong>, and <strong data-start="924" data-end="935">+250 °C</strong> is permissible under short-circuit conditions.</p>
|
||||
<h3 data-start="947" data-end="982">Construction and technical features</h3>
|
||||
<p data-start="984" data-end="1334">The cable structure consists of <strong data-start="1012" data-end="1029">copper conductors</strong> with <strong data-start="1034" data-end="1076">XLPE insulation (cross-linked polyethylene)</strong>. The cores are stranded and surrounded by a robust <strong data-start="1126" data-end="1151">black HDPE sheath</strong>. The integrated <strong data-start="1177" data-end="1201">concentric conductor</strong> made of copper wires is grounded at both ends and provides effective protection against potential differences and contact voltages.</p>
|
||||
<h3 data-start="1336" data-end="1355">Fields of application</h3>
|
||||
<p data-start="1357" data-end="1663">N2X2Y is ideal for installations in <strong data-start="1395" data-end="1442">local networks, substations, and industrial plants</strong> as well as in <strong data-start="1447" data-end="1470">power distribution systems</strong>, where high <strong data-start="1487" data-end="1515">thermal endurance</strong> and <strong data-start="1520" data-end="1552">mechanical strength</strong> are required. It provides a durable solution for demanding operating conditions – reliable and safe.</p>
|
||||
</section>
|
||||
|
||||
</ProductTabs>
|
||||
|
||||
Reference in New Issue
Block a user